Water Level Controller Installation: What to Test Before Using Auto Mode
Mohit VekariaShare
Finish a water level controller installation with a watched test before leaving the pump in Auto mode. Ask the electrician to show what happens when the roof tank is low, when it reaches the full mark, when the water source is too low, and when power returns. The useful part is seeing the controller, the motor and the water respond together. A low-tank light tells you what the controller sees. You still need to see whether the motor starts and water reaches the tank.
The electrician should handle the wiring, electrical isolation and live tests. As the person who will use the pump, you can stand in a dry, safe place and help record what you see. Agree on who will watch the tank and who will watch the panel before the first fill.
For a replacement or retrofit, use the tank sensor comparison to identify what signal the existing controller expects.
Use the water level controller wiring diagram for your exact model
Start with the labels on the controller, pump and starter. The starter switches the motor on and off. Give the electrician the model code, supply phase, rated voltage and motor current, along with the maker’s guide for that revision. The VUKAR manual library explains how to find the right reference. If it doesn’t list your exact version, ask VUKAR Technical Support for the supplied wiring guide.
For a single-phase openwell or monoblock setup with two float inputs, see the DEV-H2 installation guide. The DEV-H1 installation guide covers a single-phase borewell setup with one receiving-tank float. The motor and starter arrangement still need to match the installed unit. Use the Central Electricity Authority’s safety regulations as the reference for electrical work in India.
Before any water level controller connection is made, the installer can label the cable from each tank. Ask for labels that say which water level each cable reports. On a two-float system, one float calls for water at the roof and one tells the controller whether the source can supply it. A label at the panel helps the next electrician find the right sensor after tank cleaning or a cable replacement.
Show the electrician the tank inlet, overflow opening and the space where the float will move. Agree on the levels you can observe from a safe point. If the roof and panel are far apart, decide how the two people watching will share the moment the float changes or the pump stops. One person guessing what happened at the other end makes the first fill hard to interpret.

Agree on what a pass looks like
Set out the expected results for your setup before running the pump. Read the selected mode on the display with the electrician. If the model uses both a level input and a timer, ask which conditions must be met for a start. The agreed sequence should show how your system behaves with the settings that will be left in use.
| Condition to observe | What a pass looks like |
|---|---|
| Roof tank reaches its low start point | With water available and the installed mode permitting a run, the pump starts after any set wait and delivers water. |
| Roof tank reaches its full stop point | The motor stops at the agreed level. Water settles below the overflow. |
| Source is too low | The fitted source protection responds as designed. The electrician demonstrates it by an approved method that protects the pump. |
| Power returns after a controlled interruption | The controller follows its documented restart behaviour. Any start occurs only under the conditions that the setup permits. |

Low roof tank and enough water at the source
Let the tank reach its planned start point during a supervised test. Note the water level, the display and when the motor starts. From a safe place, watch for water at the tank inlet or another safe point where delivery can be seen. The tank may call for water before a timer or another permitted wait ends. Ask the electrician to tell you how that wait looks on your controller.
Use the same order if the pump stays still. The tank level may be low while the display shows that the controller sees a different state. Or the display may show a request while the motor remains idle. Write down both observations and any fault message. That gives the electrician a better place to start than a note that simply says Auto failed.
Keep water delivery as its own line in the record. A starter can make a sound when it switches. The panel can also show a run indication while the person at the roof is still waiting for flow. If the motor seems to be running and no water arrives as expected, let the electrician stop the test and assess the pump and water path.
Full roof tank and the level after stopping
Stay for the high-level stop. Note where the float changes state, when the motor stops and where the water finally settles. A little water can still arrive from the line after the motor stops. If the level keeps rising or the motor keeps running, use the normal stop as agreed with the electrician and report what you saw. The guide to a pump that keeps running at full tank explains what those observations can tell the installer.
After some water is drawn, watch for the next normal start. This shows whether the float can move freely in both directions. A pipe or ladder may leave room for it to rise while catching the cable on the way down. VUKAR’s float movement videos show how float movement can change a panel indication. Have the installer use the reference for your sensor and controller.
Low source while the roof tank still needs water
For a sump-to-roof setup with a separate source float, have the electrician prove the low-source response while the roof tank is calling for water. The purpose is to see whether the controller blocks a start or stops a run as the design requires. Ask the electrician to use the manufacturer’s approved test or simulation. If they can’t demonstrate the condition safely, have them mark the test as pending and complete it before handover. The sump and overhead tank guide shows how the two level signals work together.
A borewell setup with one roof-tank float may use a different way to protect the pump if the source runs short. Ask the installer which protection is fitted and what a trip looks like on the display. Use the approved test for that protection. Keep water available to the pump during testing. See the borewell dry-run protection guide for the difference between source sensing and a low motor load trip.

Power returns after an interruption
Before a controlled power-return test, ask the electrician what you should expect to see. The DEV-H2 specification, for example, lists a configurable power-on delay. The installed mode and its restart rules determine what the pump can do after power returns. Keep people clear of the pump during the demonstration because a permitted restart can happen without a button press.
Record the time power returns, the mode the panel shows and any delay or fault indication. Write down whether the pump stays off or starts and why. If the roof tank is already full, the test should show how the system handles that state on restart. Ask the electrician to show how it responds when there is also a valid call for water. Use the model guide to interpret the result.
If a fault clears during a power interruption, tell the electrician what the display showed before it went dark. A wait after power returns and a wait after a protective trip can look alike from the pump’s sound. Keep the earlier message beside the timing in your notes so the two events can be reviewed together.
Keep one handover record by the panel
For an automatic water level controller installation, a simple record can fit on one page. Write down the controller model and manual version, the pump and starter details, and which float cable serves each tank. For each test, leave room for the expected result and the actual result. Add the selected operating mode, the normal stop control and the person to contact if the pump behaves differently.

Record the water level, panel indication and pump response as separate observations. A line that says the motor stopped at the upper mark and the water settled below the overflow is useful months later. If a float is moved during tank cleaning, the installer has a reference for how the system worked before that change.
If the electrician makes an adjustment during a test, write down what changed and have them repeat the affected condition. A result from before the adjustment belongs to the old setting. Use the final recorded results to show the pump operator which display message goes with a normal wait and which one needs a service call.
Before the electrician leaves, ask them to show the normal stop control and walk through the four recorded results with the person who will use the pump. Keep the record close to the controller. If an unexpected start or stop happens later, add the displayed message and the time it appeared before calling for service.