TPO-H tank not filling

Three-Phase Pump Not Filling the Tank? TPO-H Float Signal and Fault Checks

Mohit Vekaria

If the TPO-H tank is not filling, record two levels first. One is in the tank that needs water. The other is at the source feeding the openwell or monoblock pump. The double float setup gives the installer two inputs to investigate before the motor or its built-in MCB is considered.

Start with what the display shows

Visible state What it can mean and what to do
Tank is low, with no visible fill request Compare the actual water level and the approved switching point in the installed mode. If the display disagrees, record when the mismatch began and have the installer inspect the level input.
The display suggests operation, but water is absent The command and water delivery are separate observations. Note whether the motor actually ran and whether water reached the usual outlet. Report the first missing response. In a supervised return to service, confirm both the motor response and steady delivery.
An unfamiliar indication, an unexpected stop or a visible trip Record the exact characters or lights, the time and the motor state from outside the closed enclosure. Leave protection values as commissioned. If the stop repeats or a breaker has tripped, leave further operation to a qualified electrician.

Start with the installed unit

Record the model and revision from the label, the motor nameplate and the active mode. Similar panels can have different menus. Use the installed revision’s guide for any setting, its units and the behavior of the selected mode.

TPO-H Float request · Start with the three visible observations. Receiving tank level · Source tank level · Motor or MCB state
Start with the three visible observations. Receiving tank level · Source tank level · Motor or MCB state

Use the first mismatch to choose what to report

Trace a no-fill event from the physical tank to the water outlet. If the tank is low but the controller shows no fill request, the installer can start by reviewing the level indication, float input and selected mode. If a request is visible while the motor is off, record timing, protection and any available source indication. If the motor is running and there is no water at the destination, record when you last saw delivery and whether it returned.

Use the level and the flow you can see without climbing, opening a panel or reaching into moving equipment. Some installations use a separate source-level input. Record that input if present, along with the real source condition you can safely observe. Ask the installer to demonstrate how your revision treats it. Keep the record of a normal fill as well. The first start, first water arrival and normal full stop make a useful reference for later service.

A worked example · TPO-H

At one site the overhead tank is low and the source sump has also fallen. In a double float installation, the installer can compare the recorded source state and receiving-tank request with the documented logic. In another event both conditions appear normal but the breaker is visibly tripped. Stop observing at that point and send the MCB position, both tank levels and the event time to the electrician. These are separate branches of the diagnosis.

TPO-H product details

Read the real water level and the controller state

Mark the observed low and full switching points with the installer while the sensor is in its normal installed position. Write down the physical water level, the state shown on the controller and when the motor actually starts or stops. If those three observations disagree, keep the evidence and ask the installer to review the level input and the selected mode.

A level sensor can report that the receiving tank needs water. The start can still depend on source conditions, timing and protection. During a supervised test, observe a valid request and the documented full-level stop. If there is a source input, ask the installer to demonstrate its low-water response using the prescribed method while keeping the pump protected.

Measure how much water a run actually delivers

If the flow is steady, multiply litres per minute at the delivery point by the number of minutes the pump runs. At 25 litres per minute, 10 minutes gives about 250 litres. The example assumes steady flow throughout. If the source weakens during the run, measure the volume received across the whole run before relying on that estimate.

TPO-H Float request · Compare the expected sequence with what happened. Receiving tank level · Source tank level · Motor or MCB state
Compare the expected sequence with what happened. Receiving tank level · Source tank level · Motor or MCB state

Keep supply events separate from the timer

On this three-phase model, a supply or phase-protection indication is a separate event from the end of a scheduled run. Record the indication as it appeared, its time and whether the pump was already running. A missing or unstable phase can require qualified diagnosis even when other equipment nearby has power. The electrician can compare the incoming supply, phase sequence and the installed protection settings against the approved record.

A changed indication can help the electrician decide where to measure. It cannot identify which wire or connection needs work. Keep the panel closed and leave tests of phase voltage, sequence and current to a qualified person. If the pump stops repeatedly or the breaker trips, leave further operation to the electrician. Give them the model, the motor nameplate and the exact time of the event.

Give each float its own line

In a double-float installation the receiving tank asks for water and the source state can affect whether filling is allowed. Use the names of the actual tanks. Write the receiving level and source level on separate lines with the same time. If the source is low when the receiving tank first calls, the two readings can describe an expected wait under the installed control logic.

If both tanks were in their approved operating range when the pump remained off, put that observation in the same note as the selected mode and the panel indication. Ask the installer to compare the physical level with the documented signal for each float. An electrician should handle float wiring or any test that requires access to the panel.

Separate an MCB trip from a controller stop

An MCB is a miniature circuit breaker. A visibly tripped breaker and a motor stopped by the timer are different observations. If an MCB is fitted and its state can be seen without opening a cover, record whether it changed and what the controller display showed at the same moment. If the breaker trips, leave diagnosis to an electrician.

A controller can stop the motor while the circuit breaker stays in its normal position. A timer can also end a normal run with the breaker in that position. Use the elapsed time, the active mode and any visible indication together. When the breaker or a protection indication returns, save the observations for service before another attempt to run the pump.

Choose RUN and RST from the water supply

RUN is the elapsed pump-on time. RST is the planned pause between cyclic runs in the selected mode. Choose RUN based on how long the source can deliver a steady flow, the space available where the water goes, and the motor maker’s permitted operating conditions. For RST, consider how long the source needs to recover and any minimum time between starts for the motor.

To estimate starts per hour during an uninterrupted cycle, add RUN and RST in minutes and divide 60 by the total. For example, 10 minutes on and 20 minutes off gives about two planned starts per hour. These are example values. Include any separate starts from other controls, power recovery or fault recovery when the installer reviews the motor’s actual start frequency.

Read the protection indication with the operating record

For overload, note the moment the motor stopped and whether it had reached normal running speed. The configured current response can flag a motor, supply or setup problem. For dry run, record whether water reached the outlet and when delivery weakened. An electrician can compare those events with the installed protection setup and water source.

For a voltage indication, record the time and any interruption you observed. Copy the exact characters on the display. Ask the electrician to use the instructions for the installed revision to identify the indication and decide on recovery. If the fault repeats, leave further operation to the electrician.

TPO-H Float request · Keep the display, timing and motor response in one record.
Keep the display, timing and motor response in one record.

Send the installer one usable event record

Use the exact model and revision at the top of your note. Add the symptom and the active operating mode. On the next line, put the actual clock time, elapsed motor time if known, the visible indication and the water condition. State what you expected in the same note. If a detail could not be observed safely, leave it blank and tell the electrician.

Avoid resetting first and trying to reconstruct the event later. The display, tank condition or rest period can change once the equipment is stopped or power returns. If the electrician authorizes another watched test, agree on the expected start and stop in advance and keep the same model record. If a breaker trips, a protection indication returns or the panel appears damaged, leave further operation to the electrician.

TPO-H Float request · Use this list for a supervised observation.
Use this list for a supervised observation.

Model instructions and service