Compare VUKAR three-phase DOL starter panels for borewell, openwell and monoblock pumps. Choose the pump application, motor HP and required automation below, then open the matching model for its exact specification.
Compare three phase pump starter models made by Vukar Automation. Share your shortlisted panel codes for a clear trade enquiry.
Use this selector when the pump requires a three phase DOL starter and you need to compare automation and tank-level functions. For a specific model, open its dedicated product page before ordering.
| Need | Starting point | Model direction |
|---|---|---|
| Auto Switch + Cyclic Timer | TPM-A dedicated model | For borewell, openwell or monoblock pumps without automatic tank-level control. |
| Borewell tank automation | TPA-B borewell starter | For Water Level Controller + Cyclic Timer. |
| Openwell or monoblock tank automation | TPA-O starter | For Water Level Controller + Cyclic Timer. |
| Clock-based schedule | TPM-T starter | For Auto Switch with Clock Timer + Cyclic Timer. |
The listed panel families provide voltage, overload, dry-run, phase-loss and phase-sequence monitoring together with operating indications. Protection behavior depends on correct settings and installation; verify the exact dedicated model specification.
No. It is a selector with multiple applications, control combinations and HP variants. Use the dedicated model page for exact functions.
No. Only variants that explicitly list Water Level Controller include automatic level-based tank filling.
Product videos and selection guidance: TPM-A Motor Starter Videos.

Compare Single Phase Borewell Level Control Panels (BOA). Match the pump application,...
Compare three phase digital auto switches for pump-starter control. Check compatibility with...
Compare VUKAR models before you buy VUKAR pricelist and full model comparison...
Compare Three Phase Borewell DOL Panels with Timer (TPM) for your pump...
Start with the exact motor manual. Count real starts across an hour and check minimum off time, minimum run time, start spacing and daily restrictions before changing a timer.
Start with the exact motor manual. Count real starts across an hour and check minimum off time, minimum run time, start spacing and daily restrictions before changing a timer.
Use measured delivery and the pond’s level record to plan the pumping window. Keep an independent high-level stop and decide what an interrupted run should do.
Use measured delivery and the pond’s level record to plan the pumping window. Keep an independent high-level stop and decide what an interrupted run should do.
A timed example shows how a daily window and repeating runs interact, plus what to test on your installed controller.
A timed example shows how a daily window and repeating runs interact, plus what to test on your installed controller.
A three-run example explains daily pump limits, the difference between counters and caps, and what to have your installer test.
A three-run example explains daily pump limits, the difference between counters and caps, and what to have your installer test.
Read a 100/5 A current transformer label and compare CT ratios using motor data, the meter manual and a simple display error example.
Read a 100/5 A current transformer label and compare CT ratios using motor data, the meter manual and a simple display error example.
Choose a motor protection relay by what can fail, what the relay can measure, and what the starter should do when a fault clears.
Choose a motor protection relay by what can fail, what the relay can measure, and what the starter should do when a fault clears.
Use the code, time and operating state to help an electrician trace a high- or low-voltage pump fault.
Use the code, time and operating state to help an electrician trace a high- or low-voltage pump fault.
Before choosing a pump panel, identify the complete leakage-protection chain. Compare sensing, switching, overcurrent protection and documented tests.
Before choosing a pump panel, identify the complete leakage-protection chain. Compare sensing, switching, overcurrent protection and documented tests.