Compare VUKAR single-phase motor starter panels for borewell, openwell and monoblock pumps. Choose your pump application and required controls below, then match the exact model and variant to the motor HP and current.
Choose among Vukar Automation single phase pump starter models. Ask sales for pricing on the exact panels you shortlist.
Use this page when you know the pump type and rating but still need to choose between Auto Switch, Water Level Controller, Clock Timer, Cyclic Timer, MCB and Water Level Indicator options.
| Application | Starting point | When to choose it |
|---|---|---|
| Borewell or openwell | BOM-G motor auto starter | For Cyclic Timer + Auto Switch with motor protection. |
| Borewell with tank automation | BOA-C water level controller starter | For automatic tank filling with Cyclic Timer. |
| Openwell | OPM-C openwell starter | For openwell pump operation with Cyclic Timer + Auto Switch. |
| Openwell with tank automation | OPA-B openwell level controller starter | For automatic tank filling from an openwell pump. |
| Monoblock or Tullu pump | MOM-C monoblock starter | For Cyclic Timer + Auto Switch without tank-level control. |
| Monoblock with tank automation | MOA-B monoblock level controller starter | For automatic overhead-tank filling. |
The listed starter families provide voltage, overload and dry-run protection plus operating indications. Exact functions differ by model, so use the dedicated product page and selected variant as the final specification.
No. Match the pump application, nameplate HP/current and required functions to the exact variant.
Choose an indicator only to view tank status. Choose a controller when the pump must start and stop from tank level.
Product videos and selection guidance: BOM-G product videos.

Compare Single Phase Borewell Level Control Panels (BOA). Match the pump application,...
Compare three phase digital auto switches for pump-starter control. Check compatibility with...
Compare VUKAR models before you buy VUKAR pricelist and full model comparison...
Compare Three Phase Borewell DOL Panels with Timer (TPM) for your pump...
Start with the exact motor manual. Count real starts across an hour and check minimum off time, minimum run time, start spacing and daily restrictions before changing a timer.
Start with the exact motor manual. Count real starts across an hour and check minimum off time, minimum run time, start spacing and daily restrictions before changing a timer.
Use measured delivery and the pond’s level record to plan the pumping window. Keep an independent high-level stop and decide what an interrupted run should do.
Use measured delivery and the pond’s level record to plan the pumping window. Keep an independent high-level stop and decide what an interrupted run should do.
A timed example shows how a daily window and repeating runs interact, plus what to test on your installed controller.
A timed example shows how a daily window and repeating runs interact, plus what to test on your installed controller.
A three-run example explains daily pump limits, the difference between counters and caps, and what to have your installer test.
A three-run example explains daily pump limits, the difference between counters and caps, and what to have your installer test.
Read a 100/5 A current transformer label and compare CT ratios using motor data, the meter manual and a simple display error example.
Read a 100/5 A current transformer label and compare CT ratios using motor data, the meter manual and a simple display error example.
Choose a motor protection relay by what can fail, what the relay can measure, and what the starter should do when a fault clears.
Choose a motor protection relay by what can fail, what the relay can measure, and what the starter should do when a fault clears.
Use the code, time and operating state to help an electrician trace a high- or low-voltage pump fault.
Use the code, time and operating state to help an electrician trace a high- or low-voltage pump fault.
Before choosing a pump panel, identify the complete leakage-protection chain. Compare sensing, switching, overcurrent protection and documented tests.
Before choosing a pump panel, identify the complete leakage-protection chain. Compare sensing, switching, overcurrent protection and documented tests.