VUKAR BOM-G is a single phase motor auto starter panel for 0.5–3 HP borewell or openwell pumps. It combines a cyclic timer and built-in auto switch with digital monitoring and configurable motor protection.
VUKAR BOM-G comes from pump control manufacturer Vukar Automation in Rajkot. Use the BOM-G code when requesting product support.
Choose BOM-G when a single phase borewell or openwell pump needs timer-based automatic operation and motor protection in one starter panel. Select the 0.5, 0.75, 1, 1.5, 2 or 3 HP variant that matches the motor nameplate.

View the panel’s digital operating information.

View fault indications when troubleshooting the pump.

Keep track of motor faults.

Track total motor operating time.

See when the pump is running.

Configurable overvoltage and undervoltage protection.

Configurable overload protection.

Check the overload lockout when recovering from a fault.

Use the auto-off timer for timed stopping.

Configure the power-on start delay.

Use automatic operation with the configured pump settings.

Run the pump in repeated ON and OFF cycles.

Starting-torque timer for pump operation.

Use the restart delay after a dry-run trip.

Timer recovery after a power interruption.

Record product and purchase details for support.

Check capacitor wiring with a qualified electrician.




Use the Contact page for product support.
Use BOM-G with a compatible single phase borewell or openwell pump circuit. Have a qualified electrician verify the HP variant, capacitor wiring, start/run connections and protection settings against the supplied wiring guide.
Verify the motor rating, wiring and supply conditions. Installation must be completed by a qualified electrician using the product wiring guide. Check the current Shipping Policy, Refund Policy and Contact page for delivery, replacement/return, warranty eligibility and support.
BOM-G’s listed 0.5–3 HP variants have the Cyclic Timer + Auto Switch configuration. Select the HP option that matches the pump nameplate.
Yes, for a compatible single phase borewell or openwell pump circuit. Motor rating and wiring must be checked before installation.
Product videos and selection guidance: BOM-G product videos.
VUKAR BOM-G Borewell Starter Panel: Installation and Cyclic Timer Settings

Good product.. but should be more user friendly
Very nice
Compare Single Phase Borewell Level Control Panels (BOA). Match the pump application,...
Compare three phase digital auto switches for pump-starter control. Check compatibility with...
Compare VUKAR models before you buy VUKAR pricelist and full model comparison...
Compare Three Phase Borewell DOL Panels with Timer (TPM) for your pump...
A motor running without delivery does not identify the cause. Check source availability safely and distinguish recurring prime loss from automatic control.
A motor running without delivery does not identify the cause. Check source availability safely and distinguish recurring prime loss from automatic control.
Choose continuous measurement when intermediate levels support a real decision. Compare it with point switches and plan the whole reading and control system.
Choose continuous measurement when intermediate levels support a real decision. Compare it with point switches and plan the whole reading and control system.
Identify the probe and its approved cleaning method before removing scale. Inspect insulation and wiring, then check the real water-level response.
Identify the probe and its approved cleaning method before removing scale. Inspect insulation and wiring, then check the real water-level response.
Read the configured current endpoints, apply the tank geometry and keep retained water separate. A worked example converts 12 mA into usable litres.
Read the configured current endpoints, apply the tank geometry and keep retained water separate. A worked example converts 12 mA into usable litres.
Read a 100/5 A current transformer label and compare CT ratios using motor data, the meter manual and a simple display error example.
Read a 100/5 A current transformer label and compare CT ratios using motor data, the meter manual and a simple display error example.
Choose a motor protection relay by what can fail, what the relay can measure, and what the starter should do when a fault clears.
Choose a motor protection relay by what can fail, what the relay can measure, and what the starter should do when a fault clears.
Use the code, time and operating state to help an electrician trace a high- or low-voltage pump fault.
Use the code, time and operating state to help an electrician trace a high- or low-voltage pump fault.
Before choosing a pump panel, identify the complete leakage-protection chain. Compare sensing, switching, overcurrent protection and documented tests.
Before choosing a pump panel, identify the complete leakage-protection chain. Compare sensing, switching, overcurrent protection and documented tests.