MOM-C Single Phase Monoblock (Tullu) Pump Starter Panel with Cyclic Timer
MOM-C Single Phase Monoblock (Tullu) Pump Starter Panel with Cyclic Timer
Couldn't load pickup availability
MOM-C Single Phase Monoblock (Tullu) Pump Starter Panel with Cyclic Timer is designed for 0.5–3 HP single phase monoblock (Tullu) pump variants. It combines pump operation controls with dry-run, overload and voltage protection.
VUKAR MOM-C comes from pump control manufacturer Vukar Automation in Rajkot. Compare the listed MOM-C controls with your pump task.
Which application is this model for?
Choose this model for motor protection and timed operation where automatic tank-level control is not required. MOM-C is the base Cyclic Timer and Auto Switch model without MCB, Clock Timer or tank-level control.
What makes MOM-C different?
MOM-C is the straightforward timed-control option: Cyclic Timer and Auto Switch are included, while MCB, Clock Timer, Water Level Indicator and automatic Water Level Controller are not included. It fits installations where the tank is managed separately and the requirement is motor protection plus repeating pump cycles.
MOM-C HP variants and SKUs
| Motor rating | SKU |
|---|---|
| 0.5 HP | MOM-C0 |
| 0.75 HP | MOM-C1 |
| 1 HP | MOM-C2 |
| 1.5 HP | MOM-C3 |
| 2 HP | MOM-C4 |
| 3 HP | MOM-C5 |
Key functions
- Motor monitoring: dual digital display for voltage and current, plus motor-on and fault indications for troubleshooting.
- Motor records: fault counter and total run-time counter to support maintenance tracking.
- Motor protection: overvoltage, undervoltage, overload and dry-run protection; check settings and the water source after a trip.
- Timer control: Cyclic Timer for repeating on/off cycles and Auto-Off Stop Timer for limiting a selected run duration.
- Auto Switch: manages pump operation according to the configured settings when healthy supply returns.
- Restart control: Power-On Auto-Start delay and programmable dry-run retry to manage restart timing after supply or water-source recovery.
- Construction: powder-coated metal enclosure, FRLS internal wiring and a serviceable terminal layout.
Choose the correct HP variant
Options are available for 0.5, 0.75, 1, 1.5, 2 and 3 HP pumps. Match the selected variant to the pump nameplate. Before ordering, confirm the power supply, full-load current, cable size and starter settings with a qualified electrician.
Installation and operating notes
- Install the panel in a dry, ventilated location and provide proper earthing.
- Set voltage, current, dry-run and timer parameters for the connected pump; factory/default values may not suit every installation.
- Use the timer settings for the required pump run and pause periods. This model uses timer-based operation rather than tank-level sensing.
- After a protection trip, identify and correct the cause before restarting the pump.
Warranty, dispatch and support
- 1-year product warranty when purchased from this website.
- Orders are dispatched within 0–1 working day; expected delivery is 1–5 working days from the order date across India.
- Free shipping across India.
- Technical support by WhatsApp or call: +91 63588 96254.
Compare related starter panels
- Compare all single phase monoblock (Tullu) starter panel models
- Compare single phase openwell starter panel models
- View the VUKAR starter-panel comparison and price list
Product images and feature guides
Display and everyday operation

Digital display
View supply voltage and motor current.

Fault display
View fault indications when troubleshooting the pump.

Motor fault counter
Keep track of motor faults.

Motor run-time counter
Track total motor operating time.

Motor ON indication
See when the pump is running.
Protection and control features

Voltage protection
Overvoltage and undervoltage protection for the connected pump.

Overload protection
Overload protection for the connected pump.

Overload protection guide
Check protection settings after a trip.
Timing and automatic control

Auto-off stop timer
Stop the pump after the selected running duration.

Power-on start delay
Configure restart timing after supply recovery.

Inbuilt Auto Switch
Use automatic operation with the configured pump settings.

Cyclic Timer
Run the pump in repeated ON and OFF cycles.

Dry-run restart delay
Use programmable dry-run retry to manage restart timing.

Timer settings guide
Set timer parameters for the connected pump.
Installation and ownership

Product-registration guide

Serviceable internal wiring
FRLS wiring and terminals support inspection and servicing.

Internal components

Powder-coated metal enclosure
Metal cabinet with a powder-coated finish.
Frequently asked questions
Which pump should I select MOM-C for?
Choose the matching 0.5–3 HP variant for a single phase monoblock (Tullu) pump. Verify the pump nameplate, current, wiring and settings before installation.
Is professional installation required?
Yes. A qualified electrician should complete wiring, earthing, protection settings and commissioning.
Does this model automatically control tank filling?
No. This model does not include automatic Water Level Controller operation.
Product videos and selection guidance: MOM-C product videos.
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Fully Automatic with Water Level Controller Starter Panel
Compare Single Phase Borewell Level Control Panels (BOA). Match the pump application,...
-
Three Phase Auto Switch
Compare three phase digital auto switches for pump-starter control. Check compatibility with...
-
Best Selling Products
Compare VUKAR models before you buy VUKAR pricelist and full model comparison...
-
Three Phase Borewell Fully Automatic with Timer Starter Panel
Compare Three Phase Borewell DOL Panels with Timer (TPM) for your pump...
Blog posts
View all-
VUKAR Motor Starter Fault Codes: FOL, FDR, HIU,...
Mohit VekariaVUKAR FOL, FDR, HIU, LOU and SPP: fault applicability, common manual reset, the DEV-N SET → RST exception, automatic clearing and safe escalation.
VUKAR Motor Starter Fault Codes: FOL, FDR, HIU,...
Mohit VekariaVUKAR FOL, FDR, HIU, LOU and SPP: fault applicability, common manual reset, the DEV-N SET → RST exception, automatic clearing and safe escalation.
-
Submersible Pump Starter Panel: Functions and S...
Mohit VekariaUnderstand pump starter controls, protection limits and model-selection checks before choosing a panel or adding automation.
Submersible Pump Starter Panel: Functions and S...
Mohit VekariaUnderstand pump starter controls, protection limits and model-selection checks before choosing a panel or adding automation.
-
Three Phase Digital Motor Starter Panel: Select...
Mohit VekariaCompare three-phase starter panels using motor ratings, documented protection, restart behaviour and installation requirements.
Three Phase Digital Motor Starter Panel: Select...
Mohit VekariaCompare three-phase starter panels using motor ratings, documented protection, restart behaviour and installation requirements.
-
Pump Keeps Tripping? Check the Cause Before Cha...
Mohit VekariaIf your pump repeatedly trips, investigate the detected condition before replacing the starter or increasing a setting. A correctly configured protection trip may be doing its job. A different panel...
Pump Keeps Tripping? Check the Cause Before Cha...
Mohit VekariaIf your pump repeatedly trips, investigate the detected condition before replacing the starter or increasing a setting. A correctly configured protection trip may be doing its job. A different panel...
Blog posts
-
3 Phase Digital Auto Switch: Features for India...
Use this guide to check the documented functions of an exact three-phase auto switch. Match the device to the motor and existing starter; protection depends on the supported functions, settings...
3 Phase Digital Auto Switch: Features for India...
Use this guide to check the documented functions of an exact three-phase auto switch. Match the device to the motor and existing starter; protection depends on the supported functions, settings...
-
Borewell Starter Panels: Water Level Control an...
Water level control and motor protection A borewell pump starter with water level control can automate tank filling, but level control and electrical protection are different functions. Choose the panel...
Borewell Starter Panels: Water Level Control an...
Water level control and motor protection A borewell pump starter with water level control can automate tank filling, but level control and electrical protection are different functions. Choose the panel...
Great product
Working well