VUKAR TPO-H is a 3 phase openwell and monoblock starter panel with automatic water level control, built-in MCB, cyclic timer and double float switch for pumps up to 10 HP. It also provides dry-run, overload, voltage and phase protection.
VUKAR TPO-H comes from pump control manufacturer Vukar Automation in Rajkot. For TPO-H bulk orders, send the quantity you need.

Shows voltage, current and other pump parameters for quick checks during operation.

Displays common motor fault indications to support faster troubleshooting.

Logs the number of motor faults so recurring issues can be identified.

Records cumulative motor running hours for maintenance planning.

Provides clear visual confirmation of motor operation and fault status.

Starts and stops the pump according to tank-water level through the supplied float-switch input.

Shows tank-water status for easier monitoring.

Disconnects the pump when supply voltage moves outside the configured safe range.

Stops the motor during overload or dry-run conditions to reduce the risk of motor damage.

Protects against phase loss and an incorrect phase sequence.

Keeps the system stopped after an overload until a manual reset is completed.

Stops the pump automatically after the configured running duration.

Adds a configurable delay before pump start when power returns.

Starts the pump automatically when healthy three-phase power is available.

Runs repeated ON/OFF cycles according to the configured schedule.

Stops the pump on dry run and retries after the configured recovery delay.

Restores the programmed timer cycle after a power interruption.

Supports digital product registration and both automatic and manual operation modes.

Uses terminal-lug and FRLS internal wiring designed for servicing and spare replacement.

Provides short-circuit protection for the panel wiring and pump circuit.

Uses components designed for replacement during repair.

Protects internal components in a durable metal enclosure.

Includes a cable float switch for tank-level input.
Technical support is available by WhatsApp and call at +91 63588 96254.
TPO-H is configured for three-phase openwell and monoblock pumps up to 10 HP. Select the product variant that matches the motor HP.
Product videos and selection guidance: TPO-H product videos.

Compare Single Phase Borewell Level Control Panels (BOA). Match the pump application,...
Compare three phase digital auto switches for pump-starter control. Check compatibility with...
Compare VUKAR models before you buy VUKAR pricelist and full model comparison...
Compare Three Phase Borewell DOL Panels with Timer (TPM) for your pump...
A motor running without delivery does not identify the cause. Check source availability safely and distinguish recurring prime loss from automatic control.
A motor running without delivery does not identify the cause. Check source availability safely and distinguish recurring prime loss from automatic control.
Choose continuous measurement when intermediate levels support a real decision. Compare it with point switches and plan the whole reading and control system.
Choose continuous measurement when intermediate levels support a real decision. Compare it with point switches and plan the whole reading and control system.
Identify the probe and its approved cleaning method before removing scale. Inspect insulation and wiring, then check the real water-level response.
Identify the probe and its approved cleaning method before removing scale. Inspect insulation and wiring, then check the real water-level response.
Read the configured current endpoints, apply the tank geometry and keep retained water separate. A worked example converts 12 mA into usable litres.
Read the configured current endpoints, apply the tank geometry and keep retained water separate. A worked example converts 12 mA into usable litres.
Read a 100/5 A current transformer label and compare CT ratios using motor data, the meter manual and a simple display error example.
Read a 100/5 A current transformer label and compare CT ratios using motor data, the meter manual and a simple display error example.
Choose a motor protection relay by what can fail, what the relay can measure, and what the starter should do when a fault clears.
Choose a motor protection relay by what can fail, what the relay can measure, and what the starter should do when a fault clears.
Use the code, time and operating state to help an electrician trace a high- or low-voltage pump fault.
Use the code, time and operating state to help an electrician trace a high- or low-voltage pump fault.
Before choosing a pump panel, identify the complete leakage-protection chain. Compare sensing, switching, overcurrent protection and documented tests.
Before choosing a pump panel, identify the complete leakage-protection chain. Compare sensing, switching, overcurrent protection and documented tests.