Water Level Controller Videos

Before choosing a water level controller

Use these connection examples to identify the controller family for your pump. Match the pump, starter, supply phase and tank sensors before choosing a model; then check the exact model diagram.

Compare water level controller models.

Tank-level sensors, indicators and custom multi-tank control

Separate level sensing, level indication and motor control, then define the sequence for one tank, several tanks or two pumps.

State the source and destination conditions

Draw where the water comes from, where it goes and which levels should permit, start or stop pumping. A display of a level is different from automatic control of the motor. Match the sensor arrangement and input type to the exact controller.

Several tanks need a coordinated filling arrangement

In the documented custom wired example, each tank has its own sensing and filling arrangement. More than one tank can call for water; each full tank closes its valve, and the pump stops when the required tanks are full. Tank, valve, sensor and pump quantities depend on the site design.

Two pumps serving a process are a different control problem. Independent operation, alternation, standby takeover and simultaneous operation need separate definitions and suitable individual motor control.

Commission more than the normal fill

Check low source water, full destinations, the specified retry and power-return conditions, and each tank/valve mapping. A command to open a valve is not proof of actual water delivery. Use the exact supplied guide for wiring and sensor compatibility.

Questions before choosing

Which single-phase water-level controller should I compare for my pump?

For a single-phase borewell pump, compare DEV-H1 and DEV-H3; for a single-phase openwell or monoblock pump, compare DEV-H2 and DEV-H4. This narrows the choice to the correct pump application before you select the timer functions. Use the product details to match the model’s sensor arrangement to the starter and tanks.

Which models suit a three-phase pumping installation?

DEV-G1 and DEV-G3 are the three-phase borewell options, while DEV-G2 and DEV-G4 are the three-phase openwell options. Each family combines the stated pump application with level control and its listed timing functions. Choose the pump family first and use the selected model’s diagram for the starter connections.

Which models add clock scheduling to water-level control?

DEV-H3, DEV-H4, DEV-G3 and DEV-G4 add Clock Timer functions alongside cyclic timing. H1, H2, G1 and G2 provide cyclic timing for a repeating run/rest pattern. Choose the clock-equipped option when your filling plan also needs chosen times of day.

Timer types explained

How do the float-input options match the pumping application?

The H1/H3 and G1/G3 borewell models list a single cable float switch. H2/H4 and G2/G4 list double float-switch inputs for their stated openwell or monoblock applications. Use the exact model diagram to plan the tank/source inputs and sensor positions for the chosen arrangement.

What does automatic level control add to a tank-status display?

A level controller uses the connected float-switch input to start and stop the pump according to tank level. The indicator shows the detected status so you can see the input condition. Choose the control function for automatic filling, then have the sensor position and wiring checked during commissioning.

How can cyclic timing work with tank-level control?

Level control responds to tank demand, while cyclic timing provides a repeated run/rest pattern. Together they let the selected operating mode address both the receiving tank and the pumping schedule. Describe the tank and source conditions during setup so the installer can choose suitable timing and level-input settings.

How do the connection examples help me prepare an installation?

The examples help identify the G1/G3, H1/H3 and H2/H4 controller and starter arrangements shown. Once you have selected the matching family, the exact model diagram provides the connection reference for your installation. Have a qualified electrician use that diagram to check the motor circuit, inputs and settings.

How should I choose between cable and magnetic float arrangements?

Start with the sensor type and input arrangement specified for the selected controller. The cable and magnetic float examples help illustrate how sensor movement can correspond to changing indications. Use those examples to understand the function, then confirm the actual sensor and wiring with the exact model guide.

What information helps VUKAR guidance or service discussions?

Keep the controller model, displayed fault and tank/source conditions available when describing a stop. Those details help separate a level-input question from a motor or supply condition. Use the fault guide for the indicated state and have recurring faults assessed with the installation details.

Fault-code guide

What should I prepare before selecting a water-level controller?

Prepare the supply phase, pump type, motor nameplate, existing starter details and tank/source arrangement. Add the desired schedule so the H/G family, float inputs and need for a clock can be chosen together. Have the installer test level-input response and motor operation as part of the completed setup.