VUKAR DEV-G1 is a three phase borewell water level controller with a single float switch, cyclic timer, motor monitoring and protection.
VUKAR DEV-G1 comes from pump control manufacturer Vukar Automation in Rajkot. Compare the listed DEV-G1 controls with your pump task.
Choose DEV-G1 for a three phase borewell pump that needs tank-level automation through one cable float switch and cyclic-timer control.

Shows three phase voltage, current and other pump parameters during operation.

Shows common motor-fault indications to support troubleshooting.

Records the number of detected motor faults so recurring conditions can be reviewed.

Records cumulative motor running time for maintenance planning.

Provides visual indication of motor-running and fault status.

Uses the connected float-switch input to start and stop the pump according to tank level.

Shows the tank-level status used by the controller.

Stops the pump when supply voltage moves outside the configured range.

Stops the motor during detected overload or dry-run conditions to reduce damage risk.

Checks phase availability and sequence before three phase pump operation.

Keeps the controller stopped after an overload until a manual reset is completed.

Stops the pump after the configured running duration.

Adds a configurable delay before pump start after power returns.

Supports automatic pump start when the required supply conditions are available.

Runs repeated ON/OFF cycles according to the configured schedule.

Stops the pump on dry run and retries after the configured recovery delay.

Restores the programmed timer cycle after a power interruption.

Supports digital registration for product and service records.


Technical support is available by WhatsApp and call at +91 63588 96254.

Includes a single cable float switch for borewell tank-level control.
Use with a compatible three phase borewell pump starter circuit. Have a qualified electrician verify phase sequence and connect the single float switch and motor wiring according to the supplied wiring guide.
Verify motor rating, wiring and sensor configuration. Review the current Shipping Policy, Refund Policy and Contact page.
Choose DEV-G1 for a three phase borewell pump that needs tank-level automation through one cable float switch and cyclic-timer control.
DEV-G1 uses cyclic timing for repeating ON/OFF operation and has no time-of-day clock timer. For clock scheduling in the same application, compare DEV-G3.
Follow the supplied wiring guide and use a qualified electrician.

Compare Single Phase Borewell Level Control Panels (BOA). Match the pump application,...
Compare three phase digital auto switches for pump-starter control. Check compatibility with...
Compare VUKAR models before you buy VUKAR pricelist and full model comparison...
Compare Three Phase Borewell DOL Panels with Timer (TPM) for your pump...
A motor running without delivery does not identify the cause. Check source availability safely and distinguish recurring prime loss from automatic control.
A motor running without delivery does not identify the cause. Check source availability safely and distinguish recurring prime loss from automatic control.
Choose continuous measurement when intermediate levels support a real decision. Compare it with point switches and plan the whole reading and control system.
Choose continuous measurement when intermediate levels support a real decision. Compare it with point switches and plan the whole reading and control system.
Identify the probe and its approved cleaning method before removing scale. Inspect insulation and wiring, then check the real water-level response.
Identify the probe and its approved cleaning method before removing scale. Inspect insulation and wiring, then check the real water-level response.
Read the configured current endpoints, apply the tank geometry and keep retained water separate. A worked example converts 12 mA into usable litres.
Read the configured current endpoints, apply the tank geometry and keep retained water separate. A worked example converts 12 mA into usable litres.
Read a 100/5 A current transformer label and compare CT ratios using motor data, the meter manual and a simple display error example.
Read a 100/5 A current transformer label and compare CT ratios using motor data, the meter manual and a simple display error example.
Choose a motor protection relay by what can fail, what the relay can measure, and what the starter should do when a fault clears.
Choose a motor protection relay by what can fail, what the relay can measure, and what the starter should do when a fault clears.
Use the code, time and operating state to help an electrician trace a high- or low-voltage pump fault.
Use the code, time and operating state to help an electrician trace a high- or low-voltage pump fault.
Before choosing a pump panel, identify the complete leakage-protection chain. Compare sensing, switching, overcurrent protection and documented tests.
Before choosing a pump panel, identify the complete leakage-protection chain. Compare sensing, switching, overcurrent protection and documented tests.