Dual tank water level controller illustration connecting a sump, transfer pump and overhead tank

Water Level Controller for Sump and Overhead Tank

Mohit Vekaria

A dual tank water level controller starts the transfer pump when the overhead tank needs water and the sump has enough to supply it. It stops the pump if the roof tank reaches its full point or the sump reaches its low limit. A roof-tank float and a sump float can give those two signals to a compatible controller. The lower tank can refill while the pump is off. What the pump does next depends on the controller’s restart settings and whether the roof tank still needs water.

Follow the water from the ground tank to the roof. This setup is common when a house stores water at ground level first, then lifts it to the tank that feeds the taps. This article covers one transfer pump, one source sump and one receiving tank. For a single roof tank fed by a borewell or a separate supply, start with the overhead tank controller guide.

Dual tank water level controller diagram showing the roof request and the sump permission
The sump gives permission to run. The roof tank requests water.

Two tank signals and two reasons to stop

The roof tank asks for water at its low mark. Its full mark ends the fill. The sump input tells the controller if there is enough water to let the pump run. If the sump falls to its low limit before the roof tank is full, the pump stops. The roof tank can still need water after that stop. The controller should keep the pump off until the source is ready again and its restart conditions allow another run.

What the tanks are doing Expected pump response in Auto
Roof low, sump ready Start once the controller allows it, after any configured delay.
Roof reaches full Stop even if there is plenty of water in the sump.
Sump reaches low limit while the roof needs water Stop or block a start, according to the configured source input.
Sump recovers and the roof still needs water Follow the model’s restart rules. The pump may wait or need a reset.
Sump recovers and the roof is already full Remain off in the intended tank-filling mode.

With a two-tank water level controller, the roof tank can sit halfway between low and full while the pump fills it, or while the pump is off and someone uses water. Both are normal when the controller uses separate start and stop points.

Record what happened just before the pump stopped. A full-tank stop and a source-low stop can look the same from the kitchen. The panel may show different indications, depending on the model.

Leave enough water above the pump inlet

The sump float needs to stop the pump while there is still enough water for that pump to operate as specified. The right point depends on the inlet position, the pump and how the water moves inside the sump. A surface pump’s suction pickup and a submerged pump can have different requirements. Have the installer use the pump maker’s minimum water or submergence requirements. Groundwater, stored supply and rainwater can also bring debris that affects a float’s movement. Keep it where it can move freely and where the installer can reach it later.

Water level controller for sump and overhead tank diagram showing a source stop and pump inlet
The low-sump mark leaves the reserve specified for the installed pump.

Watch what happens if the ground tank refills slowly. If the pump starts again as soon as a little water enters, it may soon empty that small reserve and stop again. The way to avoid repeated short runs depends on the model. Ask the installer what margin the sump sensor provides between stop and recovery, and which restart settings are available. Keep the stop level, recovery behaviour and any delay in the handover notes.

A roof-tank request can outlast the water in the sump. A successful full-tank test tells you the roof sensor works. Have the installer also demonstrate a low-source stop while the roof tank still needs water.

Choosing a water level controller with two float switches

Ask for a water level controller for sump and overhead tank that can act on both level inputs. VUKAR lists the DEV-H2 for single-phase openwell or monoblock use and the DEV-G2 for three-phase openwell or monoblock use. The model pages list two cable float switches. The electrician still needs the pump nameplate and existing starter details to confirm that the controller, starter and supply suit each other. If the job also needs a new starter, compare the complete starter panels with water level control for the actual pump type.

A cable float, a probe and a continuous level sensor use different ways to report water level. Match the input type listed for the exact controller. A supplier should be able to tell you what arrives in the box and which extra cable or mounting parts are required. Ask for the route from the sump to the control panel and from the panel to the roof tank as two separate cable lengths. This makes the quote easier to read and can help identify which cable an electrician needs to trace later. Omron’s level switch guide explains how a conductive sensor differs from a switch.

Will the sump last through one roof-tank fill?

Suppose the roof tank needs 300 litres to reach its stop point and the pump delivers about 25 litres per minute. With the taps closed, the fill takes about 12 minutes. If the sump has only 200 usable litres above its cutoff and no water is entering it, the pump can run for about 8 minutes before the sump reaches that cutoff. The roof tank would still need about 100 litres. A stop at that point can be the expected result of the lower sensor doing its job.

Dual tank water level controller example comparing 300 litres needed with 200 usable litres
Illustrative volumes. Inflow, demand and pump delivery change the actual result.

Usable sump water is the volume between the current level and the pump’s permitted stop level. A tank sold as a 1,000-litre sump can have much less usable water on a given morning. Try the tank volume and fill-time calculator with your measurements. Note when water is still entering the sump or being drawn from the roof tank. Either can change the time you see.

For a practical record, note the two levels before the first morning run and again when the pump stops. If the sump still has water below the cutoff, that is the reserve the installer left for the inlet. The shape of the sump can make level marks a poor guide to litres unless you know its dimensions. A tape mark or a sketch of the two levels can be enough for a useful discussion about why filling paused.

Record a full-tank stop and a low-sump stop

Have a qualified electrician use the exact manual for the connections and any live tests. Start with a safe fill. Record the water levels, the panel indication and whether the pump starts. Have the installer demonstrate each stop condition separately, using an approved method that protects the pump from running dry. Then observe what the controller does when its source input returns to a ready state. Write down whether it waits, restarts or asks for a reset.

Dual tank water level controller test diagram for full roof, low sump and source recovery
Test the full roof and low sump separately, then record the model’s response to recovery.

If a tanker or rainwater pipe fills the sump, the same transfer logic applies once there is enough usable water. The inlet that fills the sump still needs its own suitable control. The transfer controller is responsible for the pump feeding the roof. Ask the plumber how each inlet stops and the electrician how the pump is allowed to run. Keep the VUKAR model manual with the record. If you later find water coming out of the roof overflow, the overflow troubleshooting guide helps you describe what to report.

What if the sump is full and the pump is still off?

First note whether the roof tank is below its start point. A full sump only gives the system permission to run. A roof tank above the low mark may have no active request. If the roof tank is low, read the closed panel’s display and note whether Auto is selected, a wait is shown or a fault appears. Some models use a delay after power returns or after a protective stop. Record the message before calling the installer. They can compare it with the model’s documented sequence.

A recent tank cleaning is worth mentioning. The float may have been moved when the tank was emptied or its cable may sit differently around the inlet. Keep hands clear of the pump and the float when the system can start. If the pump starts at odd times, share a time and the readings from both tanks. The two readings give the installer more to work with than the sound of the motor alone.

For the handover, keep one small card by the panel with the model, the low sump stop, the full roof stop and what should happen after the source refills. Ask the electrician to show you those events while the equipment is easy to observe. The person who calls for service next year can use that card even if they weren’t there when the pump was fitted.