Digital Auto Switch Supplier in Kakinada
Mohit VekariaShare

If you are looking for a digital auto switch supplier in Kakinada, consider VUKAR DEV-K1 when a compatible single-phase transfer pump already has a sound starter and you want repeated run and rest periods. Get the electrician to confirm the condition of the existing starter before ordering. Where the pump has to stop as soon as the roof tank fills or the sump drops low, include suitable level controls in the job. The DEV-K1 timer works by elapsed time.
Start at the building sump
An April 2025 report on Kakinada’s water project identifies two city storage sources, the summer tank at Aratlakatta and the Maharshi Sambamurthy tank in Samalkot. A separate municipal water-loss action plan proposed using floats in household reservoirs to curb overflow. The two documents describe different points in the route. At a property that stores municipal water in a sump before pumping it to the roof, work out which inlet control fills the sump and which control runs the transfer pump.
If the roof tank is slow to refill, note whether the sump itself had water when the pump was called. A pause in the transfer can come from an empty sump, a failed starter or a fault elsewhere on the property. The time on the wall clock cannot identify the cause. Give the electrician the observed water level and what the starter was doing at that moment.

Use the volume still needed to buy the right control
For a worked example, assume the pump delivers 25 litres per minute and nobody draws water during the test. When the roof tank needs 300 litres, it reaches the chosen mark in 12 minutes. If it starts closer to full and only needs 150 litres, it reaches the same mark in 6 minutes. A fixed 12-minute run would still have 6 minutes left when the second fill reaches the mark. A roof-level switch can give a separate stop signal at that mark. The real fill rate and level need to come from your installation.
For the next run, the useful note is the space in the roof tank before the start, alongside the water available in the sump. The timer may ask for another run after the rest period. The job sheet should say what has to be true for that next run to be allowed.
Keep the starter or price a replacement
| What the electrician finds | What to put in the quote |
|---|---|
| Starter and protection pass inspection | Price the DEV-K1 retrofit and a witnessed run and rest test |
| Starter trips or shows damage | Price fault diagnosis first and compare a suitable replacement if needed |
| The tank levels must decide when the pump can run | Include separate, compatible sump-low and roof-full controls |
VUKAR lists DEV-K1 as a single-phase digital auto switch with a 1–35 A range, motor monitoring and protection, and a cyclic timer. The range is one input to the installer’s choice. Ask them to compare the motor rating and the existing starter with the device documentation. For a time-of-day schedule, use the single-phase auto switch comparison to discuss a clock-timer model.

Ask for a witnessed handover
Send the supplier a photo of the motor plate and the outside of the starter. Write down the run and rest pattern you want and what the pump should do if the sump is low or the roof tank is already full. Ask the electrician to show the result with the enclosure closed, record what happens after power returns, and explain which normal stop control the caretaker can reach. The DEV-K1 setup guide lists the checks to record.
Keep that record beside the starter. On the next service visit, it gives the electrician both the expected behaviour and the actual symptom. A reliable manual stop, the intended response to loss of supply and the expected level controls belong on that page.