VUKAR OPA-H is a single phase automatic openwell starter for 0.5–3 HP pumps. It combines a Water Level Controller, included cable float switch, Water Level Indicator, Cyclic Timer, inbuilt MCB and motor protection. The pump starts and stops automatically according to the connected tank-level sensor.
VUKAR OPA-H comes from pump control manufacturer Vukar Automation in Rajkot. Use the OPA-H code when requesting product support.

Shows supply voltage, motor current, timer values and fault information for routine monitoring.

Shows fault indications to help identify common pump and supply problems.

Records the number of motor trips so recurring faults can be reviewed.

Tracks cumulative motor operating hours for maintenance records.

Shows whether the pump is running and provides a visible fault indication.

Automatically starts and stops the pump according to the connected tank-level sensor.

Shows the connected tank's full or empty status.

Stops the motor when supply voltage moves outside the user-set limits.

Stops the pump when motor current indicates overload or dry-run conditions, using user-set thresholds.

Requires a manual reset after the configured overload lockout condition.

Stops the motor after the user-set run duration.

Delays motor restart after the electricity supply returns.

Can start the pump automatically after healthy power returns, according to the configured settings.

Runs repeated ON and OFF cycles using user-set durations.

After a dry-run trip, waits for the user-set interval before attempting a restart.

Retains the configured timer operation after a power interruption.

Lets the buyer register the product and keep the purchase record linked to support and warranty service.

Uses lug-based FRLS internal wiring on terminals so internal parts can be serviced or replaced.

Includes a 440 V run capacitor selected for the corresponding motor rating.

Provides short-circuit protection for the starter panel's incoming circuit.

Replacement control-panel parts can be sourced for service; confirm the exact compatible part before purchase.

The metal enclosure shields the internal control components. Installation and earthing must be completed by a qualified electrician.

The powder-coated metal cabinet protects the internal components during normal installed use.

For installation, fault codes and warranty support, call or WhatsApp +91 63588 96254.

A cable float switch is supplied for automatic tank-level sensing.
A one-year parts replacement warranty applies to manufacturing defects. Requests for a defective, damaged, wrong or not-as-described product must be raised within seven days of delivery; change-of-mind returns are not offered. Shipping is free across India. Orders dispatch in 0–1 working day and delivery is normally expected 1–5 working days from the order date, subject to courier or postal service. An optional paid three-year extended warranty is available.
Does OPA-H automatically start and stop the pump by tank level?
Yes. The connected cable float switch senses tank level, and the Water Level Controller operates the pump according to its configured logic.
Is the cable float switch included?
Yes. A cable float switch is supplied for automatic tank-level sensing.
Is an MCB included?
Yes. OPA-H includes an inbuilt MCB for short-circuit protection of the starter panel's incoming circuit.
How should it be installed?
Have a qualified electrician verify the motor rating, float switch, capacitor, protection settings, earthing and power wiring before operation.
Who handles order and delivery support?
Call or WhatsApp +91 95121 72271, or email online@vukar.com. For technical support, contact +91 63588 96254.
Product videos and selection guidance: OPA-H product videos.
VUKAR OPA-H Openwell Starter Panel: Installation and Water-Level Settings

Compare Single Phase Borewell Level Control Panels (BOA). Match the pump application,...
Compare three phase digital auto switches for pump-starter control. Check compatibility with...
Compare VUKAR models before you buy VUKAR pricelist and full model comparison...
Compare Three Phase Borewell DOL Panels with Timer (TPM) for your pump...
Start with the exact motor manual. Count real starts across an hour and check minimum off time, minimum run time, start spacing and daily restrictions before changing a timer.
Start with the exact motor manual. Count real starts across an hour and check minimum off time, minimum run time, start spacing and daily restrictions before changing a timer.
Use measured delivery and the pond’s level record to plan the pumping window. Keep an independent high-level stop and decide what an interrupted run should do.
Use measured delivery and the pond’s level record to plan the pumping window. Keep an independent high-level stop and decide what an interrupted run should do.
A timed example shows how a daily window and repeating runs interact, plus what to test on your installed controller.
A timed example shows how a daily window and repeating runs interact, plus what to test on your installed controller.
A three-run example explains daily pump limits, the difference between counters and caps, and what to have your installer test.
A three-run example explains daily pump limits, the difference between counters and caps, and what to have your installer test.
Read a 100/5 A current transformer label and compare CT ratios using motor data, the meter manual and a simple display error example.
Read a 100/5 A current transformer label and compare CT ratios using motor data, the meter manual and a simple display error example.
Choose a motor protection relay by what can fail, what the relay can measure, and what the starter should do when a fault clears.
Choose a motor protection relay by what can fail, what the relay can measure, and what the starter should do when a fault clears.
Use the code, time and operating state to help an electrician trace a high- or low-voltage pump fault.
Use the code, time and operating state to help an electrician trace a high- or low-voltage pump fault.
Before choosing a pump panel, identify the complete leakage-protection chain. Compare sensing, switching, overcurrent protection and documented tests.
Before choosing a pump panel, identify the complete leakage-protection chain. Compare sensing, switching, overcurrent protection and documented tests.