MOM-V Single Phase Monoblock Pump Starter with Water Level Indicator is designed for 0.5–3 HP single phase monoblock (Tullu) pump variants. It combines pump operation controls with dry-run, overload and voltage protection.
VUKAR MOM-V comes from pump control manufacturer Vukar Automation in Rajkot. Ask our sales team about MOM-V supply for your project.
Choose this model when you need tank-level visibility without automatic tank-filling control. MOM-V shows tank status; it is not an automatic Water Level Controller.
MOM-V is the monitoring model: the Water Level Indicator shows tank status from the cable float switch, but it does not start and stop the pump by tank level. It includes Cyclic Timer and motor protection, without MCB or Clock Timer. Choose MOA-B instead if automatic tank filling is required.
| Motor rating | SKU |
|---|---|
| 0.5 HP | MOM-V0 |
| 0.75 HP | MOM-V1 |
| 1 HP | MOM-V2 |
| 1.5 HP | MOM-V3 |
| 2 HP | MOM-V4 |
| 3 HP | MOM-V5 |
Options are available for 0.5, 0.75, 1, 1.5, 2 and 3 HP pumps. Match the selected variant to the pump nameplate. Before ordering, confirm the power supply, full-load current, cable size and starter settings with a qualified electrician.

View supply voltage and motor current.

View fault indications when troubleshooting the pump.

Keep track of motor faults.

Track total motor operating time.

See when the pump is running.

View the connected tank’s water-level status.

Overvoltage and undervoltage protection for the connected pump.

Dry-run protection for the connected pump.

Check protection settings after a trip.

Stop the pump after the selected running duration.

Configure restart timing after supply recovery.

Use automatic operation with the configured pump settings.

Run the pump in repeated ON and OFF cycles.

Use programmable dry-run retry to manage restart timing.

Set timer parameters for the connected pump.


FRLS wiring and terminals support inspection and servicing.


Metal cabinet with a powder-coated finish.

Supplied cable float switch provides tank-status input.
Choose the matching 0.5–3 HP variant for a single phase monoblock (Tullu) pump. Verify the pump nameplate, current, wiring and settings before installation.
Yes. A qualified electrician should complete wiring, earthing, protection settings and commissioning.
No. This model does not include automatic Water Level Controller operation.
Product videos and selection guidance: Water-level indicator videos.

Compare Single Phase Borewell Level Control Panels (BOA). Match the pump application,...
Compare three phase digital auto switches for pump-starter control. Check compatibility with...
Compare VUKAR models before you buy VUKAR pricelist and full model comparison...
Compare Three Phase Borewell DOL Panels with Timer (TPM) for your pump...
Start with the exact motor manual. Count real starts across an hour and check minimum off time, minimum run time, start spacing and daily restrictions before changing a timer.
Start with the exact motor manual. Count real starts across an hour and check minimum off time, minimum run time, start spacing and daily restrictions before changing a timer.
Use measured delivery and the pond’s level record to plan the pumping window. Keep an independent high-level stop and decide what an interrupted run should do.
Use measured delivery and the pond’s level record to plan the pumping window. Keep an independent high-level stop and decide what an interrupted run should do.
A timed example shows how a daily window and repeating runs interact, plus what to test on your installed controller.
A timed example shows how a daily window and repeating runs interact, plus what to test on your installed controller.
A three-run example explains daily pump limits, the difference between counters and caps, and what to have your installer test.
A three-run example explains daily pump limits, the difference between counters and caps, and what to have your installer test.
Read a 100/5 A current transformer label and compare CT ratios using motor data, the meter manual and a simple display error example.
Read a 100/5 A current transformer label and compare CT ratios using motor data, the meter manual and a simple display error example.
Choose a motor protection relay by what can fail, what the relay can measure, and what the starter should do when a fault clears.
Choose a motor protection relay by what can fail, what the relay can measure, and what the starter should do when a fault clears.
Use the code, time and operating state to help an electrician trace a high- or low-voltage pump fault.
Use the code, time and operating state to help an electrician trace a high- or low-voltage pump fault.
Before choosing a pump panel, identify the complete leakage-protection chain. Compare sensing, switching, overcurrent protection and documented tests.
Before choosing a pump panel, identify the complete leakage-protection chain. Compare sensing, switching, overcurrent protection and documented tests.