DM-SP-CYC-96 Single Phase Motor Protection with Cyclic Timer

DM-SP-CYC-96 Single Phase Motor Protection with Cyclic Timer

Regular price Rs. 1,549.00
Regular price Rs. 2,250.00 Sale price Rs. 1,549.00
Sale Sold out
Taxes included. Free shipping across India. View shipping policy.
Quantity
Included Motor Protection + Cyclic Timer

Selected Google reviews of Vukar Automation

DM-SP-CYC-96 single phase motor protection device is designed for pump control circuits that need motor protection with cyclic pump scheduling. It monitors voltage/current and stops the motor-control output when configured electrical faults are detected.

VUKAR DM-SP-CYC-96 comes from pump control manufacturer Vukar Automation in Rajkot. For DM-SP-CYC-96 bulk orders, send the quantity you need.

When should you choose this model?

Choose DM-SP-CYC-96 when you need motor protection without tank-level automation plus repeated ON/OFF cyclic scheduling. Confirm the phase, wiring, control circuit and motor rating before installation.

Core functions

  • Voltage/current monitoring and fault indication
  • Overvoltage, undervoltage, overload and dry-run protection
  • Cyclic Timer, Auto-Off Stop Timer and power-on start delay
  • Fault counter, total run-time counter and automatic/manual modes

Installation and setup

  • Install with a compatible pump starter or contactor control circuit.
  • Use a qualified electrician to verify wiring, earthing and the motor rating.
  • Set voltage, current, dry-run and timer parameters for the connected pump.
  • After a trip, identify and correct the fault before restart.

Warranty, dispatch and support

  • 1-year product warranty when purchased from this website.
  • Orders are dispatched within 0–1 working day; expected delivery is 1–5 working days from the order date across India.
  • Free shipping across India.
  • Technical support by WhatsApp or call: +91 63588 96254.

Compare before buying

Product feature guide

Display and everyday operation

Dual digital display – DM-SP-CYC-96

Dual digital display

Shows single phase voltage and current during operation.

Fault indication – DM-SP-CYC-96

Fault indication

Displays detected motor faults to support troubleshooting.

Motor fault counter – DM-SP-CYC-96

Motor fault counter

Records the number of motor-fault events.

Motor run-time counter – DM-SP-CYC-96

Motor run-time counter

Records cumulative motor running time for maintenance reference.

Motor status indication – DM-SP-CYC-96

Motor status indication

Shows motor ON and fault status.

Protection and control features

Voltage protection – DM-SP-CYC-96

Voltage protection

Stops the control output when voltage moves outside configured limits.

Overload and dry-run protection – DM-SP-CYC-96

Overload and dry-run protection

Stops the motor-control output during configured overload or dry-run conditions.

Overload safety lockout – DM-SP-CYC-96

Overload safety lockout

Keeps the control output stopped after an overload until reset.

Timing and automatic control

Auto-off stop timer – DM-SP-CYC-96

Auto-off stop timer

Stops the pump after the configured running duration.

Power-on start delay – DM-SP-CYC-96

Power-on start delay

Adds a configured delay before restart after power returns.

Built-in auto switch – DM-SP-CYC-96

Built-in auto switch

Provides automatic control when the configured supply conditions are healthy.

Cyclic timer – DM-SP-CYC-96

Cyclic timer

Runs repeated ON/OFF cycles according to configured timings.

Starting-torque timing – DM-SP-CYC-96

Starting-torque timing

Controls the configured starting sequence on supported single phase installations.

Dry-run restart timer – DM-SP-CYC-96

Dry-run restart timer

Retries after the configured recovery delay following a dry-run stop.

Timer power-failure recovery – DM-SP-CYC-96

Timer power-failure recovery

Restores the configured timer cycle after a power interruption.

Installation and ownership

Digital registration and operating modes – DM-SP-CYC-96

Digital registration and operating modes

Supports digital product registration and automatic/manual operation modes.

Technical support – DM-SP-CYC-96

Technical support

WhatsApp and call support is available at +91 63588 96254.

Frequently asked questions

Where does this protection device fit?

Use it with a compatible motor starter or contactor control circuit. The starter power circuit remains required for the installation.

How should the device be set up for my pump?

A qualified electrician should set the parameters to match the motor nameplate, supply and installation.

Product videos and selection guidance: Digital meter selection: display examples.

View full details
1 of 4
  • 3 Phase Digital Auto Switch - VUKAR

    3 Phase Digital Auto Switch: Features for India...

    Use this guide to check the documented functions of an exact three-phase auto switch. Match the device to the motor and existing starter; protection depends on the supported functions, settings...

    3 Phase Digital Auto Switch: Features for India...

    Use this guide to check the documented functions of an exact three-phase auto switch. Match the device to the motor and existing starter; protection depends on the supported functions, settings...

  • The Importance of Motor Protection in Borewell Submersible Starter Panels with Water Level Controller - VUKAR

    Borewell Starter Panels: Water Level Control an...

    Water level control and motor protection A borewell pump starter with water level control can automate tank filling, but level control and electrical protection are different functions. Choose the panel...

    Borewell Starter Panels: Water Level Control an...

    Water level control and motor protection A borewell pump starter with water level control can automate tank filling, but level control and electrical protection are different functions. Choose the panel...

1 of 4