Recommended OPM-C Settings: Openwell Run/Rest and Motor Protection
Record the two cyclic timer values for the selected mode, using the labels shown on your installed revision, and record the commissioned overload, dry-run and voltage protection settings.
Recommended OPM-C Settings: Openwell Run/Rest and Motor Protection
Record the two cyclic timer values for the selected mode, using the labels shown on your installed revision, and record the commissioned overload, dry-run and voltage protection settings.
Recommended OPA-T Settings: Openwell Tank Levels and Clock Scheduling
Confirm the low and full tank switching points, set the clock and enabled weekdays for the approved schedule, and keep the RUN/RST and protection values in the commissioning record.
Recommended OPA-T Settings: Openwell Tank Levels and Clock Scheduling
Confirm the low and full tank switching points, set the clock and enabled weekdays for the approved schedule, and keep the RUN/RST and protection values in the commissioning record.
Recommended OPA-H Settings: Tank Levels, Cyclic Timer and Start Delay
Confirm the openwell installation’s low and full tank responses, record RUN and RST for its approved cyclic mode, and document the AST delay if automatic starting after power returns was...
Recommended OPA-H Settings: Tank Levels, Cyclic Timer and Start Delay
Confirm the openwell installation’s low and full tank responses, record RUN and RST for its approved cyclic mode, and document the AST delay if automatic starting after power returns was...
Recommended OPA-B Settings: Openwell Tank-Level Control and Run/Rest
Record the receiving tank’s low and full switching points and the selected filling mode. Where the openwell installation uses a repeating cycle, record the approved run and rest minutes and...
Recommended OPA-B Settings: Openwell Tank-Level Control and Run/Rest
Record the receiving tank’s low and full switching points and the selected filling mode. Where the openwell installation uses a repeating cycle, record the approved run and rest minutes and...
Recommended BOM-W Settings: Level Indication, Timed Stop and Protection Defaults
Check the indicated tank level against the actual tank, record the approved RUN duration, and keep the commissioned current and voltage protection limits. Keep a separate note of breaker state...
Recommended BOM-W Settings: Level Indication, Timed Stop and Protection Defaults
Check the indicated tank level against the actual tank, record the approved RUN duration, and keep the commissioned current and voltage protection limits. Keep a separate note of breaker state...
Recommended BOM-V Settings: Tank-Level Display and RUN Timed Stop
Record what the tank level display shows at known water levels and save the RUN duration in minutes for the approved timed-stop mode. Keep the motor protection limits and delays...
Recommended BOM-V Settings: Tank-Level Display and RUN Timed Stop
Record what the tank level display shows at known water levels and save the RUN duration in minutes for the approved timed-stop mode. Keep the motor protection limits and delays...