TPM-W recommended parameter settings cover for level indication and mode-specific timers.

Recommended TPM-W Settings: Level Indication, RUN and Mode-Specific AST/RST

Mohit Vekaria
TPM-W recommended parameter settings cover for level indication and mode-specific timers.

TPM-W recommended parameter settings are a commissioning record for your exact three-phase dol pump starter. Record the indicated and actual tank level, and read RUN in minutes for the timed-stop test. Keep AST and RST at their documented or commissioned values unless the installed mode calls for a change. Record any visible breaker indication separately.

TPM-W recommended parameter settings checklist for installation and commissioned defaults.
Record installation settings separately from the values already commissioned.

What belongs on the first-installation checklist?

A three-phase pump starts with a partially filled tank. The panel gives a level indication and the installer observes the timed stop. During handover, keep the displayed level, stop time and visible breaker position on different lines so later observations can be compared.

Write the panel model and variant as they appear on the label. Add the controller revision and the motor’s rated current and voltage from the nameplate or pump paperwork. The model tells you which functions the panel offers. The actual motor, supply, water source and operating mode determine the settings that belong in the record. Use the revision-matched instructions for the menu labels and save procedure. VUKAR product manuals and parameter reference

Setting What it does What to record
OL / OLT Overload current threshold and delay before an overload trip. Approved amps (A) and seconds (s).
DR / DRT Low-current threshold for dry-run detection and its own trip delay. Approved amps and seconds.
HIU / LOU High and low supply-voltage limits. Both limits in volts (V).
Three-phase supply The installer confirms phase conditions and normal motor operation before automatic starts. Commissioned phase check and any observed indication.
Level indication Shows tank status from the installed level input. Actual water level and matching display indication.
RUN Elapsed run duration in the applicable auto-off mode. Saved minutes (min), start time and observed stop.

Read current limits and delays as pairs

OL and DR are current limits. OLT and DRT are delays. With overload protection, the controller looks for current above the approved overload limit for the associated time. With dry-run protection, it looks for current below its approved threshold for the corresponding time. A short change in the current reading and a continuing condition tell the controller different things. Record the limit and delay together so the next installer can see both parts of the decision.

TPM-W recommended parameter settings showing overload and dry-run current limits with their delays.
Use amps for OL and DR and seconds for OLT and DRT.

Keep the two voltage limits in the same record, with HIU for the upper limit and LOU for the lower limit. A voltage shown on the front display is the reading at that moment. Write a measured reading and a saved limit in different fields. If a protection trip repeats, note the displayed indication and the conditions around the stop so an installer can investigate the motor, supply or water source.

Have a qualified installer choose protection values using the actual motor and supply. Values from a different pump or controller revision can mislead even when the model name looks familiar. Ask the installer to record who approved the final limits and the date they were set. For wiring and work inside the enclosure, use a licensed electrical contractor and have the supply isolated and verified dead. Central Electricity Authority safety regulations

VUKAR TPM-W three-phase starter panel

VUKAR product

TPM-W Three-Phase Starter Panel

For compatible pump installations. See the product gallery and model features for level indication and mode-specific timers.

View TPM-W

Level indication and mode-specific timers

TPM-W includes a water level indicator and an MCB. In the timed-stop test use RUN. In a repeating cycle RST is the rest interval, and in the applicable automatic-start mode AST relates to power return. Record which mode was active when the pump stopped or waited.

Compare the display with the tank at known water levels that the installer can observe safely. Note the indication at each observed level and check it again during normal operation. In this setup the display shows tank status. Keep its reading in a separate field from any timer or protection setting that controls motor operation.

Set the RUN duration for a watched timed-stop test in the mode approved for the installed revision. Start with water available and enough receiving space. Read the saved value back in minutes before the run. Record the time the motor actually starts and the time it stops. If it runs beyond the planned stop, use the normal stop control from a dry, safe location and have the installer review the selected mode and saved duration.

Before enabling automatic starting, have the installer confirm the supply phases and normal motor operation using the matching equipment instructions. Write the observed phase indication next to the current operating mode. If the phase or voltage indication changes, record the event time and call the installer. Keep the enclosure closed while observing the display.

Use the timed-stop checklist for the RUN test. If the installer commissioned automatic starting after power returns, AST describes the applicable start delay. If the installer commissioned a repeating cycle, RST describes the rest interval. Leave either value as commissioned unless the selected mode and matching instructions call for a change.

TPM-W recommended parameter settings test checkpoints for level indication and mode-specific timers.
Use the actual mode to identify the applicable timer after a stop or delay.

Keep the other applicable values as commissioned

Keep the documented defaults for the exact controller revision or the values the installer already commissioned. If TRQ appears on your panel, leave its starting torque time at that approved value. Keep current-sensor selection, marked CTS where applicable, and current or voltage calibration as commissioned. Those values belong with the installed hardware and measurements. Have the installer review changes using the matching instructions.

Ask the installer which fault restart options apply to the installed revision. Record the approved restart behavior separately from the timed-stop mode. Use the code VUKAR issues for your unit if one-time WRT registration is required. Keep the recorded mode and labels with the values so they still make sense at the next service visit.

Write down what happened during the watched run

For an unexpected stop, collect the display code, tank level, elapsed run time and visible breaker state. If the supply returned shortly before the event, add that time so the installer can review the power-return setting in context.

TPM-W recommended parameter settings handover record with model, saved values and watched test.
Keep this information with the pump and panel paperwork.

Keep three things together for handover. First, identify the panel variant, revision, motor and water source. Second, copy the saved settings and units, including the mode that was tested. Third, write when the test started and stopped, what the display showed and any unexpected event. Date the record and add the installer’s name. This gives you a baseline if a motor, sensor or water source changes later.

If the values already in the panel and the settings on an old service sheet differ, keep both records until the installer has identified the current approved set. A note such as “read from panel” or “approved after test” tells you which numbers were observed and which ones were accepted for the installation. Leave a missing unit or value blank until it can be confirmed.

When reporting a problem, send the panel model and revision, motor rating, current mode, display code and the time of the event. Include the saved timer or protection setting that relates to the event and note any recent change in the installation. VUKAR technical support

Use the TPM-W installation and setup guide for the panel-specific setup sequence and the VUKAR guide to pump timer types for how the different timing modes behave. At the end of the visit, keep the approved settings sheet where the next owner or technician can find it.