DM-TP-LLC-96 tank not filling

Tank Not Filling? DM-TP-LLC-96 Float Signal and Fault Checks

Mohit Vekaria

If the DM-TP-LLC-96 tank is not filling, record the actual water level, what the meter shows and whether the three-phase starter moves the motor. Keep the water at the tank inlet in a separate line. The first difference between the expected and actual sequence points to the next diagnosis.

Start with what the display shows

Visible state What it can mean and what to do
Tank is low, with no visible fill request Compare the actual water level and the approved switching point in the installed mode. If the display disagrees, record when the mismatch began and have the installer inspect the level input.
The display suggests operation, but water is absent The command and water delivery are separate observations. Note whether the motor actually ran and whether water reached the usual outlet. Report the first missing response. In a supervised return to service, confirm both the motor response and steady delivery.
An unfamiliar indication, an unexpected stop or a visible trip Record the exact characters or lights, the time and the motor state from outside the closed enclosure. Leave protection values as commissioned. If the stop repeats or a breaker has tripped, leave further operation to a qualified electrician.

Start with the installed unit

Record the model and revision from the label, the motor nameplate and the active mode. Similar panels can have different menus. Use the installed revision’s guide for any setting, its units and the behavior of the selected mode.

DM-TP-LLC-96 First observations · Receiving tank level · Meter indication · Three-phase starter
First observations · Receiving tank level · Meter indication · Three-phase starter

Use the first mismatch to choose what to report

Trace a no-fill event from the physical tank to the water outlet. If the tank is low but the controller shows no fill request, the installer can start by reviewing the level indication, float input and selected mode. If a request is visible while the motor is off, record timing, protection and any available source indication. If the motor is running and there is no water at the destination, record when you last saw delivery and whether it returned.

Use the level and the flow you can see without climbing, opening a panel or reaching into moving equipment. Some installations use a separate source-level input. Record that input if present, along with the real source condition you can safely observe. Ask the installer to demonstrate how your revision treats it. Keep the record of a normal fill as well. The first start, first water arrival and normal full stop make a useful reference for later service.

A worked example · DM-TP-LLC-96

Suppose a workshop tank is low, the DM-TP-LLC-96 shows the usual request, and the starter remains inactive. Record the time and any separate supply indication. In another example the motor runs but water is absent at the usual inlet. Give the technician that record separately, since it places the missing response after the motor started. The installed level inputs and the external starter need to be considered with the water source.

DM-TP-LLC-96 Model settings guide

Read the real water level and the controller state

Mark the observed low and full switching points with the installer while the sensor is in its normal installed position. Write down the physical water level, the state shown on the controller and when the motor actually starts or stops. If those three observations disagree, keep the evidence and ask the installer to review the level input and the selected mode.

A level sensor can report that the receiving tank needs water. The start can still depend on source conditions, timing and protection. During a supervised test, observe a valid request and the documented full-level stop. If there is a source input, ask the installer to demonstrate its low-water response using the prescribed method while keeping the pump protected.

Choose RUN and RST from the water supply

RUN is the elapsed pump-on time. RST is the planned pause between cyclic runs in the selected mode. Choose RUN based on how long the source can deliver a steady flow, the space available where the water goes, and the motor maker’s permitted operating conditions. For RST, consider how long the source needs to recover and any minimum time between starts for the motor.

To estimate starts per hour during an uninterrupted cycle, add RUN and RST in minutes and divide 60 by the total. For example, 10 minutes on and 20 minutes off gives about two planned starts per hour. These are example values. Include any separate starts from other controls, power recovery or fault recovery when the installer reviews the motor’s actual start frequency.

DM-TP-LLC-96 Compare the operating sequence · Receiving tank level · Meter indication · Three-phase starter
Compare the operating sequence · Receiving tank level · Meter indication · Three-phase starter

Record the meter and starter as separate devices

This motor-protection meter is part of the installed control circuit. A visible state on the meter tells you what that device is reporting. The actual response also depends on the connected starter, the motor and the water path. Write down the meter model and the starter model. Keep the motor nameplate with the service record.

If you can see an operating indication without opening the enclosure, record when it appeared and what the motor did. If the motor ran, write down when water reached the normal outlet. These times give the electrician a way to identify the first missing response. Leave terminal tests, relay or contactor checks and current-sensing work with qualified service. The meter model does not establish the correct motor settings by itself.

Read the real water level and the controller state

Mark the observed low and full switching points with the installer while the sensor is in its normal installed position. Write down the physical water level, the state shown on the controller and when the motor actually starts or stops. If those three observations disagree, keep the evidence and ask the installer to review the level input and the selected mode.

A level sensor can report that the receiving tank needs water. The start can still depend on source conditions, timing and protection. During a supervised test, observe a valid request and the documented full-level stop. If there is a source input, ask the installer to demonstrate its low-water response using the prescribed method while keeping the pump protected.

Keep supply events separate from the timer

On this three-phase model, a supply or phase-protection indication is a separate event from the end of a scheduled run. Record the indication as it appeared, its time and whether the pump was already running. A missing or unstable phase can require qualified diagnosis even when other equipment nearby has power. The electrician can compare the incoming supply, phase sequence and the installed protection settings against the approved record.

A changed indication can help the electrician decide where to measure. It cannot identify which wire or connection needs work. Keep the panel closed and leave tests of phase voltage, sequence and current to a qualified person. If the pump stops repeatedly or the breaker trips, leave further operation to the electrician. Give them the model, the motor nameplate and the exact time of the event.

Read the protection indication with the operating record

For overload, note the moment the motor stopped and whether it had reached normal running speed. The configured current response can flag a motor, supply or setup problem. For dry run, record whether water reached the outlet and when delivery weakened. An electrician can compare those events with the installed protection setup and water source.

For a voltage indication, record the time and any interruption you observed. Copy the exact characters on the display. Ask the electrician to use the instructions for the installed revision to identify the indication and decide on recovery. If the fault repeats, leave further operation to the electrician.

DM-TP-LLC-96 Display and response record
Display and response record

Keep two clean records for a repeat event

An older note helps if it lists the same model, revision and operating mode. Put it beside the new one. If a pipe was changed, the pump serviced or the water source was different, label that change with its date. State which times came from direct observation. A photograph of the closed panel and the model label helps the installer match the right documentation.

If a second watched test is safe and the installer authorizes it, agree in advance which single event to observe. Use the approved setup and keep people clear of the motor and pump. Capture the visible state and the actual response at the same moment. A shorter note with good timestamps is easier to use than a long note made from memory after a reset.

DM-TP-LLC-96 Observations for a supervised test
Observations for a supervised test

Model instructions and service