Water Pump Timer Switch Supplier in Nashik
Mohit VekariaShare
If you need a Water Pump Timer Switch Supplier in Nashik, SubmersibleShop.com offers the VUKAR DEV-P2 for a compatible existing three-phase pump starter. It is useful to compare when a vineyard needs to move stored water at a set time. Start with the amount of water to move and the measured pump flow. The time for that transfer and the time for drip watering are two separate jobs.
Vineyard water transfer from a farm pond
A Nashik grape orchard study indexed by FAO AGRIS compared applying canal water to a field with storing canal water in a farm pond for later irrigation. It explains why the canal turn and the crop's water demand can fall at different times. If your farm uses a pond, name the pump and the job before asking for a timer. In this guide, the pump moves water from the pond to a smaller storage tank before the drip system takes water.
Write down how much water is already in the small tank and how much more it needs. Also note whether the drip line takes water during the transfer. If the drip system is running at the same time, the receiving tank may fill more slowly. You need the net fill rate, which means the water entering the tank minus water leaving it. A separate transfer window makes the two jobs easier to measure and compare.

Three-phase pump clock timer or repeat cycle?
A clock timer starts a run at a set time of day. A cyclic timer repeats a chosen run and rest period. The DEV-P2 product page lists both modes for a compatible three-phase starter. Use the clock mode for a known window. Compare repeat timing if the job really needs the same run and rest pattern. Ask the electrician to confirm what happens after a power cut. The restart choice matters if the next job starts before anyone gets back to the pump.
Worked example · A 30-minute transfer window
Suppose the tank needs 1,800 litres and the outlet delivers 60 litres per minute. At steady flow, that takes 30 minutes. If the flow falls to 45 litres per minute, it takes 40 minutes. A 30-minute window would then move only 1,350 litres.
| Situation | Choice to compare |
|---|---|
| One daily transfer window | Use a clock schedule on a compatible starter |
| Same run and rest each time | Compare cyclic timing |
| Level needs to stop the pump | Specify an independent level stop |
A timer measures time. It cannot tell when a pond runs low or a receiving tank fills. Where level must stop the pump, arrange a suitable stop signal as a separate part of the job. Ask the installer to check both ends of the water route. The pump must have enough source water, and the tank must have enough room before a run starts.
Calculate farm pond pump run time with real flow
Ask the installer to measure flow at the actual outlet used for the transfer. The flow at a different pipe or height can be different. Divide the litres needed by the litres delivered in one minute when flow is stable. Compare that time with the allowed window and leave the level stop in place. The worked example assumes the drip line is off and the receiving tank has enough space. Record which pipe and valve position you used during the test. If a filter is cleaned or the outlet changes, measure again before changing the clock. Note the date and the pond level beside the result. Two readings taken under similar conditions are more useful than two readings with an unknown setup.
What to send for a Nashik pump timer quote
Send the motor plate, current starter label and a sketch showing the pond and receiving tank. Include the measured flow, litres needed, allowed run window and what should stop the pump early. Tell the supplier if power often returns after the window has closed. Ask for the exact timer, any separate level control and the tests included in the quote. Give your delivery PIN code to check dispatch.
Open the three-phase auto switch comparison, then send the pump details and water route to VUKAR. Ask for a quote for this transfer job and agree who will verify the stop signals before the first unattended run.