DEV-P2 3 Phase Auto Switch with Clock & Cyclic Timers
DEV-P2 3 Phase Auto Switch with Clock & Cyclic Timers
Couldn't load pickup availability
VUKAR DEV-P2 is a three phase digital auto switch with clock and cyclic timers for pump automation, monitoring and motor protection.
Who Should Choose This Model
Choose DEV-P2 when a three phase pump needs both time-of-day scheduling and repeated ON/OFF cycles.
Product and Installation Videos
Monitoring and Control
High-Brightness Dual Digital Display
Shows three phase voltage, current and other pump parameters during operation.

Fault Display Indication
Shows common motor-fault indications to support troubleshooting.

Motor Fault Counter
Records the number of detected motor faults so recurring conditions can be reviewed.

Motor Run-Time Counter
Records cumulative motor running time for maintenance planning.

Motor-On and Fault Indication
Provides visual indication of motor-running and fault status.

Digital Clock Display
Shows the clock and schedule information used for timed operation.

Overvoltage and Undervoltage Protection
Stops the pump when supply voltage moves outside the configured range.

Overload and Dry-Run Protection
Stops the motor during detected overload or dry-run conditions to reduce damage risk.

Phase-Loss and Phase-Sequence Protection
Checks phase availability and sequence before three phase pump operation.

Overload Safety Lockout
Keeps the controller stopped after an overload until a manual reset is completed.

Auto-Off Stop Timer
Stops the pump after the configured running duration.

Power-On Auto-Start Timer
Adds a configurable delay before pump start after power returns.

Protection and Automation
Built-In Auto Switch
Supports automatic pump start when the required supply conditions are available.

Cyclic Timer
Runs repeated ON/OFF cycles according to the configured schedule.

Clock Timer
Supports time-of-day pump scheduling through the clock timer.

Programmable Dry-Run Restart Timer
Stops the pump on dry run and retries after the configured recovery delay.

Timer Power-Failure Recovery
Restores the programmed timer cycle after a power interruption.

Digital Product Registration
Supports digital registration for product and service records.

Total Daily Run-Time Control
Controls the pump's total daily operating time according to the programmed setting.

Cyclic-Timer Operating Hours
Allows the cyclic timer's daily operating window to be configured.

Multi-Event Real-Time Scheduler
Supports up to 20 programmed start and stop events.

Hierarchical Timer
Supports individually configured cycles within a broader operating schedule.
Protective Enclosure
Uses a protective enclosure intended to support stable controller operation.

Technical Support
Technical support is available by WhatsApp and call at +91 63588 96254.

Selection and Installation
Use with a compatible three phase pump starter circuit. Verify motor rating, phase sequence, clock settings and wiring before commissioning.
Before Ordering
Verify motor rating, wiring and sensor configuration. Review the current Shipping Policy, Refund Policy and Contact page.
FAQ
Which application is DEV-P2 for?
Choose DEV-P2 when a three phase pump needs both time-of-day scheduling and repeated ON/OFF cycles.
Does it include a clock timer?
Yes. This model includes both clock and cyclic timers.
Compare Related Models
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Fully Automatic with Water Level Controller Starter Panel
Compare Single Phase Borewell Level Control Panels (BOA) for your pump installation....
-
Three Phase Auto Switch
Compare three phase digital auto switches for pump-starter control. Check compatibility with...
-
Best Selling Products
Compare VUKAR models before you buy VUKAR pricelist and full model comparison...
-
Three Phase Borewell Fully Automatic with Timer Starter Panel
Compare Three Phase Borewell DOL Panels with Timer (TPM) for your pump...
Blog posts
View all-
VUKAR Motor Starter Fault Codes: FOL, FDR, HIU,...
Mohit VekariaVUKAR FOL, FDR, HIU, LOU and SPP: fault applicability, common manual reset, the DEV-N SET → RST exception, automatic clearing and safe escalation.
VUKAR Motor Starter Fault Codes: FOL, FDR, HIU,...
Mohit VekariaVUKAR FOL, FDR, HIU, LOU and SPP: fault applicability, common manual reset, the DEV-N SET → RST exception, automatic clearing and safe escalation.
-
Submersible Pump Starter Panel: Functions and S...
Mohit VekariaUnderstand pump starter controls, protection limits and model-selection checks before choosing a panel or adding automation.
Submersible Pump Starter Panel: Functions and S...
Mohit VekariaUnderstand pump starter controls, protection limits and model-selection checks before choosing a panel or adding automation.
-
Three Phase Digital Motor Starter Panel: Select...
Mohit VekariaCompare three-phase starter panels using motor ratings, documented protection, restart behaviour and installation requirements.
Three Phase Digital Motor Starter Panel: Select...
Mohit VekariaCompare three-phase starter panels using motor ratings, documented protection, restart behaviour and installation requirements.
-
Motor Protection Device: Functions, Limits and ...
Mohit VekariaA correctly selected starter panel can disconnect a pump for the faults it is designed and configured to detect. It cannot guarantee uninterrupted water supply, prevent every motor failure or...
Motor Protection Device: Functions, Limits and ...
Mohit VekariaA correctly selected starter panel can disconnect a pump for the faults it is designed and configured to detect. It cannot guarantee uninterrupted water supply, prevent every motor failure or...
Blog posts
-
Features of 3 Phase Digital Auto Switch for Ind...
Use this guide to check the documented functions of an exact three-phase auto switch. Match the device to the motor and existing starter; protection depends on the supported functions, settings...
Features of 3 Phase Digital Auto Switch for Ind...
Use this guide to check the documented functions of an exact three-phase auto switch. Match the device to the motor and existing starter; protection depends on the supported functions, settings...
-
The Importance of Motor Protection in Borewell ...
Water level control and motor protection A borewell pump starter with water level control can automate tank filling, but level control and electrical protection are different functions. Choose the panel...
The Importance of Motor Protection in Borewell ...
Water level control and motor protection A borewell pump starter with water level control can automate tank filling, but level control and electrical protection are different functions. Choose the panel...