Water Level Controller Price in India: What Will Your Setup Cost?
Mohit VekariaShare
The water level controller price for the VUKAR DEV-H and DEV-G range was ₹3,149 to ₹4,949 on 13 November 2026. That was the listed device price. Your installed cost also depends on the tank sensors, extra cable, the condition of your existing starter and the electrician’s work. A home with a borewell and one roof tank can have a simpler quote than a home that pumps from an underground sump to the roof.
Start with your water source and pump type. A lower-priced model can be a good fit when your starter already works and you need just one tank sensor. If the pump can run out of water in a lower tank, include the cost of sensing that tank before you compare quotes. Then put the equipment and installation on the same sheet so you can see what each seller is offering.
Automatic water level controller price by setup
These are four VUKAR models with a cyclic timer, which lets the pump run and rest in set periods. The exact model matters. Two devices from the same range can suit different pumps and use different numbers of float switches.
| Pump setup | Controller and listed price |
|---|---|
| Single-phase borewell, one float | DEV-H1 · ₹3,849 |
| Single-phase openwell or monoblock, two floats | DEV-H2 · ₹4,299 |
| Three-phase borewell, one float | DEV-G1 · ₹3,149 |
| Three-phase openwell or monoblock, two floats | DEV-G2 · ₹3,599 |
VUKAR also lists models with clock scheduling for fixed times of day. The listed single-phase models with that feature were ₹4,499 and ₹4,949. Their three-phase counterparts were ₹3,799 and ₹4,249. Within the listed phase and pump pairings, the clock-timer model was ₹650 more. If your tank only needs to refill as the level falls, a clock timer may add little value. If you need to limit filling to specific hours, the scheduling option can matter. See the single-phase DEV-H range and three-phase DEV-G range.
The cited product pages list the device prices with taxes included. Ask whether your electrician’s quote includes applicable taxes and who pays for any extra visit. Prices can change, and these devices serve different setups. The lower three-phase price only helps if your motor and starter are compatible. The pump label gives its phase, voltage and rated current. Your electrician can match the controller to that information and the starter already on the wall.

Water level controller installation cost examples
Here are three ways the bill can add up. The controller prices are the listed prices above. The extra amounts are sample figures for the arithmetic. Use your own quote for cable, parts, labour and testing.
| Example scope | Device + sample extras | Example total |
|---|---|---|
| Single-phase borewell. Reuse a compatible starter and cable route. | ₹3,849 + ₹900 | ₹4,749 |
| Single-phase sump to roof. Add cable for the lower float and allow for testing both tanks. | ₹4,299 + ₹1,400 | ₹5,699 |
| Three-phase openwell to roof. Allow for extra cable and starter control work. | ₹3,599 + ₹1,800 | ₹5,399 |
If you’re comparing two offers, write the installed totals on the same line. In the second example, a quote that says ₹4,299 for the device plus ₹1,400 for the work comes to ₹5,699. A second quote of ₹5,500 might look better. Ask whether it includes the lower-tank float, the cable to it and a test that shows the pump stops when the sump is low. If the second quote includes the same scope, compare who will return if the float needs an adjustment after the first week.
The two-float setup needs a route for each sensor. If the roof tank and sump sit on opposite sides of the house, the usable cable path can be much longer than the straight line between them. A higher quote may include new conduit or work around a wall or floor that the lower quote leaves to you. Ask the installer to write the cable length and labour as separate items.
An older starter may still be fine. Its model and condition determine whether the controller can work with it. If the installer proposes a new contactor, ask what part of the motor circuit it will switch and why the present starter needs work. A contactor is a switch designed to handle a motor circuit. Its price belongs under parts, with labour on a separate line.

A controller or a complete starter panel?
Ask for two prices if you’re replacing a worn starter. One quote can show the separate controller and all the starter work needed to fit it. The other can show a complete panel with water-level control. As one example, the VUKAR catalogue lists the 1 HP single-phase borewell BOA-C2 panel at ₹5,049. That is a price for the listed panel before site work. Compare the exact version and what comes in the box. See the BOA-C starter panel listing.

What belongs in an installed-price quote?
The controller and sensors. Ask for the exact model number and the included float switches. One float can control the roof tank in a suitable borewell setup. A sump-to-roof system can use a second float so the lower water supply can stop the pump even when the roof tank calls for water. If you already have sensors, include their model in the quote so the installer can account for compatible reuse or replacement. The sump-to-overhead-tank guide shows what each float does.
The cable and mounting work. Write the length from each tank to the controller box along the route the cable can actually take. Ask who supplies conduit, clips or mounting hardware. On a roof, a clean route along a wall may be easier to service later than a shorter run across the floor. If the installer wants to reuse cable, ask which part can stay and which part needs to change.
The starter parts. If the price includes a contactor, enclosure or a replacement starter, have those named on the quote. Matching the pump takes more than the HP number. Phase and rated current also matter. An existing compatible starter can keep costs down. A poor fit can mean paying for another visit and another set of parts.
The final test. Have a qualified electrician do the installation and supervised tests using the exact model manual. Include the start at low water, stop at full, response to a low water source where applicable and behaviour after power returns. Ask to see how Auto mode responds to each state. The VUKAR manual library has documentation by model.
Ask how the quote handles changes once work begins. A concealed cable route or a starter that needs a new part can change the bill after the first visit. Ask for the price of that extra work before it goes ahead. On the final invoice, keep the controller model, sensor count and cable route with the itemised amount. The next electrician can use that record if a float fails or the tank is moved. It also tells you which part of the original price paid for equipment and which part paid for fitting it.

Why some controller prices look much lower
Listings can use similar names for a level relay, a complete device kit or an app-controlled system. The relay reads a sensor and sends a switching signal. The quote can still need probes, an enclosure or a compatible starter. A kit may include its sensors, but what is in the box depends on the exact model. An app-controlled system may add a display or alerts. Those features can be worth paying for if you need remote monitoring.
Look at what the price buys for your own tank. Voltkart’s water level controller guide shows panel-mounted probe controllers, while FloSenso shows an app-controlled product with cable-length choices. Compare each system with the same scope for installation and testing.
There’s a useful question for a two-float quote. Ask what the system will do when the overhead tank is low but the sump is too low to pump. Have the supplier describe which sensor supplies the stop signal, when the pump can run again and how the electrician will show that during handover. If the quote only says “two sensors,” that answer will tell you more about the setup you’re paying for.
What to send before you ask for a price
Take a photo of the motor label and the existing starter label. Note whether the water comes from a borewell, openwell or sump. Write down the number of roof tanks and the rough cable distance from each tank to the controller. Send those details with a request for one installed total and an itemised split for equipment, cable, starter parts and labour.
If you already have two quotes, put them side by side and ask each installer to fill in any missing items. Start with the sensor count and the first supervised fill. Those two details tell you whether both prices cover the same work. For help picking the right type of controller, use the automatic water level controller buying guide.