Single Phase Openwell / Monoblock Automatic Water Level Controller, Motor Safety, Cyclic Timer & Double Float Switch (DEV-H2) VUKAR

Automatic Water Level Controller Supplier for Surat

Mohit Vekaria

Picture this. The watchman starts the pump at the usual hour, but the ground tank is still low. By evening, residents in the top flats are asking for water. If your Surat society uses a compatible single-phase openwell or monoblock pump to lift water from a ground tank to a roof tank, VUKAR supplies the DEV-H2 two-float automatic water level controller from Rajkot. First find out which tank is low when the problem starts.

Dindoli shows why the clock can be wrong

Surat Municipal Corporation describes area-based supply windows in its water FAQ. In August 2026, Loktej reported that the Dindoli distribution station in Limbayat split its supply into four time blocks for different areas. That is a reason to review an old timer setting after a supply change. In a society with a ground tank, the levels in its own tanks tell the caretaker when water is available and when the roof tank needs a refill.

SMC water supply FAQ · Loktej’s Dindoli report

Ask the caretaker what happened before you buy

Have them record two readings when residents report a shortage. Is there water in the ground tank? Is there water in the roof tank? A float switch senses the water level in one tank. A two-float setup uses a separate signal for each tank.

What the caretaker sees What to do next
Both tanks are low Ask whether water is reaching the ground tank. Buying a controller will leave the incoming supply unchanged.
Ground tank has water, roof tank stays low Have the electrician check whether the pump starts and moves water. If the pump works and the missed starts are manual, ask about two-float control.
Roof tank overflows while the pump runs Ask the electrician to test the existing stop control and float before replacing the unit.

A 15-minute refill example

Suppose a roof tank needs another 450 L and the pump delivers 30 L/min at the roof. That is about 15 minutes at that flow. If the ground tank has only 300 L of usable water, a 15-minute timer still asks for more water than the source can provide. The ground-tank float can call for a stop at its set low level. Measure the actual flow at the outlet or ask the installer for it. The two numbers here are illustrative.

Compare the device and the installed quote

DEV-H2 is listed for a compatible single-phase openwell or monoblock pump with two float switches and a repeating cycle timer. If the society also requires starts at fixed times of day, compare DEV-H4. It adds a clock scheduler. For a three-phase pump, check the DEV-G range with your electrician. Send a nameplate photo before choosing a model.

Compare the VUKAR controller range

VUKAR DEV-H2 water level controller and cyclic timer features
VUKAR DEV-H2 water level controller and cyclic timer features

Ask for the exact model, both floats and their cable lengths, any extra cable and panel parts, fitting charges, applicable warranty and dispatch to the building’s PIN code. Split the hardware and fitting costs so both quotes cover the same job. Keep one photo of the final model label with the society’s purchase record.

Before signing off, ask the electrician to demonstrate two stops during handover. One when the roof tank reaches its full level and one when the ground tank reaches the low limit. Ask the caretaker to watch so they know what the display means on the next shift.

Copy this message for a Surat quote

Surat, PIN [____]. One ground tank and one roof tank. Pump nameplate and existing starter photos attached. Please confirm DEV-H2 fit and quote both floats, cable lengths, any extra parts, fitting and dispatch separately.

Send the Surat quote request