Single Phase Openwell Starter with Level Indicator & MCB, 0.5–3 HP (OPM-W)

Single Phase Openwell Starter with Level Indicator & MCB, 0.5–3 HP (OPM-W)

Regular price Rs. 3,949.00
Regular price Rs. 5,860.00 Sale price Rs. 3,949.00
Sale Sold out
Taxes included. Free shipping across India. View shipping policy.
Quantity
HP Rating
Included Cyclic Timer + Auto Switch

Selected Google reviews of Vukar Automation

VUKAR OPM-W is a single phase openwell starter for 0.5–3 HP pumps. It combines a Water Level Indicator, included cable float switch, MCB, Cyclic Timer, Auto Switch and motor protection. The indicator shows full or empty tank status; for automatic tank-level switching, choose an OPA model.

VUKAR OPM-W comes from pump control manufacturer Vukar Automation in Rajkot. Compare the listed OPM-W controls with your pump task.

Display and everyday operation

High brightness dual digital display on a single phase panel

High-brightness dual display

Shows supply voltage, motor current, timer values and fault information for routine monitoring.

Fault display indication showing motor error codes on the panel

Fault display

Shows fault indications to help identify common pump and supply problems.

Motor fault counter logging and displaying the number of trips

Motor fault counter

Records the number of motor trips so recurring faults can be reviewed.

Motor run time counter logging cumulative pump operating hours

Total run-time counter

Tracks cumulative motor operating hours for maintenance records.

Motor on indication confirming the pump is currently running

Motor ON and fault indication

Shows whether the pump is running and provides a visible fault indication.

Protection and control features

Water level indicator giving visual confirmation of tank status

Water Level Indicator

Shows the connected tank's full or empty status.

Overvoltage and undervoltage protection keeping the motor in safe limits

Overvoltage and undervoltage protection

Stops the motor when supply voltage moves outside the user-set limits.

Dry run protection cutting power when the water source runs dry

Overload and dry-run protection

Stops the pump when motor current indicates overload or dry-run conditions, using user-set thresholds.

Overload safety lockout halting operation after repeated overload trips

Overload safety lockout

Requires a manual reset after the configured overload lockout condition.

Timing and automatic control

Auto off stop timer switching the motor off after a set duration

Auto-off stop timer

Stops the motor after the user-set run duration.

Power on auto start timer delaying restart after supply returns

Power-on start delay

Delays motor restart after the electricity supply returns.

Inbuilt auto switch managing automatic pump start and stop

Inbuilt Auto Switch

Can start the pump automatically after healthy power returns, according to the configured settings.

Cyclic timer scheduler running the pump in timed on off cycles

Cyclic Timer

Runs repeated ON and OFF cycles using user-set durations.

Programmable auto restart timer retrying the pump after dry run cutoff

Dry-run auto-restart timer

After a dry-run trip, waits for the user-set interval before attempting a restart.

Timer with power failure recovery keeping schedules after outages

Power-failure recovery

Retains the configured timer operation after a power interruption.

Installation and ownership

Digital product registration keeping warranty records secure and accessible

Digital product registration

Lets the buyer register the product and keep the purchase record linked to support and warranty service.

Panel internals with ISI marked copper wiring on heavy duty lugs

Serviceable internal wiring

Uses lug-based FRLS internal wiring on terminals so internal parts can be serviced or replaced.

Built in 440 V motor run capacitor for stable starting

440 V motor run capacitor

Includes a 440 V run capacitor selected for the corresponding motor rating.

Inbuilt MCB giving short circuit protection in the panel

Inbuilt MCB

Provides short-circuit protection for the starter panel's incoming circuit.

Easy availability of spare parts and control panel accessories

Spare-parts support

Replacement control-panel parts can be sourced for service; confirm the exact compatible part before purchase.

Protective metal enclosure information badge

Protective enclosure

The metal enclosure shields the internal control components. Installation and earthing must be completed by a qualified electrician.

Powder coated metal enclosure protecting the panel internals

Powder-coated metal enclosure

The powder-coated metal cabinet protects the internal components during normal installed use.

Technical support assistance badge

Technical support

For installation, fault codes and warranty support, call or WhatsApp +91 63588 96254.

Cable float switch included for automatic tank level sensing

Cable float switch included

A cable float switch is supplied for tank-status sensing used by the Water Level Indicator.

Who should choose OPM-W?

  • 0.5–3 HP single phase openwell pumps
  • Visual tank-level status, MCB and time-based Cyclic Timer operation
  • Automatic power-return start with motor protection

Warranty, shipping and support

A one-year parts replacement warranty applies to manufacturing defects. Requests for a defective, damaged, wrong or not-as-described product must be raised within seven days of delivery; change-of-mind returns are not offered. Shipping is free across India. Orders dispatch in 0–1 working day and delivery is normally expected 1–5 working days from the order date, subject to courier or postal service. An optional paid three-year extended warranty is available.

Frequently asked questions

Does OPM-W automatically start or stop the pump by tank level?
No. Its Water Level Indicator displays tank status. Choose an OPA model for automatic level control.

Are the MCB and cable float switch included?
Yes. The panel includes an MCB, and a cable float switch is supplied for tank-status sensing.

How should it be installed?
Have a qualified electrician verify the motor rating, MCB, float switch, capacitor, protection settings, earthing and power wiring before operation.

Who handles order and delivery support?
Call or WhatsApp +91 95121 72271, or email online@vukar.com. For technical support, contact +91 63588 96254.

Product videos and selection guidance: Water-level indicator videos.

View full details
1 of 4
  • 3 Phase Digital Auto Switch - VUKAR

    3 Phase Digital Auto Switch: Features for India...

    Use this guide to check the documented functions of an exact three-phase auto switch. Match the device to the motor and existing starter; protection depends on the supported functions, settings...

    3 Phase Digital Auto Switch: Features for India...

    Use this guide to check the documented functions of an exact three-phase auto switch. Match the device to the motor and existing starter; protection depends on the supported functions, settings...

  • The Importance of Motor Protection in Borewell Submersible Starter Panels with Water Level Controller - VUKAR

    Borewell Starter Panels: Water Level Control an...

    Water level control and motor protection A borewell pump starter with water level control can automate tank filling, but level control and electrical protection are different functions. Choose the panel...

    Borewell Starter Panels: Water Level Control an...

    Water level control and motor protection A borewell pump starter with water level control can automate tank filling, but level control and electrical protection are different functions. Choose the panel...

1 of 4