Three-Phase Pump Not Filling the Tank? TPB-H Float Signal and Fault Checks
Mohit VekariaShare
If the TPB-H tank is not filling, record the actual tank level, the single float request and the starter’s visible state. TPB-H also has a built-in miniature circuit breaker, or MCB. A visible trip belongs in its own line because a cyclic pause can leave the pump off without moving the breaker.
Start with what the display shows
| Visible state | What it can mean and what to do |
|---|---|
| Tank is low, with no visible fill request | Compare the actual water level and the approved switching point in the installed mode. If the display disagrees, record when the mismatch began and have the installer inspect the level input. |
| The display suggests operation, but water is absent | The command and water delivery are separate observations. Note whether the motor actually ran and whether water reached the usual outlet. Report the first missing response. In a supervised return to service, confirm both the motor response and steady delivery. |
| An unfamiliar indication, an unexpected stop or a visible trip | Record the exact characters or lights, the time and the motor state from outside the closed enclosure. Leave protection values as commissioned. If the stop repeats or a breaker has tripped, leave further operation to a qualified electrician. |
Start with the installed unit
Record the model and revision from the label, the motor nameplate and the active mode. Similar panels can have different menus. Use the installed revision’s guide for any setting, its units and the behavior of the selected mode.

Use the first mismatch to choose what to report
Trace a no-fill event from the physical tank to the water outlet. If the tank is low but the controller shows no fill request, the installer can start by reviewing the level indication, float input and selected mode. If a request is visible while the motor is off, record timing, protection and any available source indication. If the motor is running and there is no water at the destination, record when you last saw delivery and whether it returned.
Use the level and the flow you can see without climbing, opening a panel or reaching into moving equipment. Some installations use a separate source-level input. Record that input if present, along with the real source condition you can safely observe. Ask the installer to demonstrate how your revision treats it. Keep the record of a normal fill as well. The first start, first water arrival and normal full stop make a useful reference for later service.
A worked example · TPB-H
Suppose the borewell was delivering water and the tank is still low when the pump stops. If the breaker is visibly tripped, stop the observation there and record the position and time from outside. If the breaker stays in its normal position and the pump starts after its approved rest, record that sequence. Either record is more useful than saying the starter failed. In both cases the installer needs the actual tank level when the pump stopped.
Read the real water level and the controller state
Mark the observed low and full switching points with the installer while the sensor is in its normal installed position. Write down the physical water level, the state shown on the controller and when the motor actually starts or stops. If those three observations disagree, keep the evidence and ask the installer to review the level input and the selected mode.
A level sensor can report that the receiving tank needs water. The start can still depend on source conditions, timing and protection. During a supervised test, observe a valid request and the documented full-level stop. If there is a source input, ask the installer to demonstrate its low-water response using the prescribed method while keeping the pump protected.
Measure how much water a run actually delivers
If the flow is steady, multiply litres per minute at the delivery point by the number of minutes the pump runs. At 25 litres per minute, 10 minutes gives about 250 litres. The example assumes steady flow throughout. If the source weakens during the run, measure the volume received across the whole run before relying on that estimate.

Keep supply events separate from the timer
On this three-phase model, a supply or phase-protection indication is a separate event from the end of a scheduled run. Record the indication as it appeared, its time and whether the pump was already running. A missing or unstable phase can require qualified diagnosis even when other equipment nearby has power. The electrician can compare the incoming supply, phase sequence and the installed protection settings against the approved record.
A changed indication can help the electrician decide where to measure. It cannot identify which wire or connection needs work. Keep the panel closed and leave tests of phase voltage, sequence and current to a qualified person. If the pump stops repeatedly or the breaker trips, leave further operation to the electrician. Give them the model, the motor nameplate and the exact time of the event.
Separate an MCB trip from a controller stop
An MCB is a miniature circuit breaker. A visibly tripped breaker and a motor stopped by the timer are different observations. If an MCB is fitted and its state can be seen without opening a cover, record whether it changed and what the controller display showed at the same moment. If the breaker trips, leave diagnosis to an electrician.
A controller can stop the motor while the circuit breaker stays in its normal position. A timer can also end a normal run with the breaker in that position. Use the elapsed time, the active mode and any visible indication together. When the breaker or a protection indication returns, save the observations for service before another attempt to run the pump.
Follow the command to the pump
A controller can show a request while the motor is still off. A starter switches motor power when the control circuit permits it. Observe the display, the starter’s visible response and water delivery as separate facts. These observations give the electrician a place to start without asking you to open the enclosure or touch conductors.
If the display shows that the pump should be running but there is no water, write down whether you could see or hear the motor run from a safe location. If the motor runs but delivery is absent or weak, record how long it ran and when the flow changed. Keep the display photo and the times together so the installer can compare them with the actual settings.
Choose RUN and RST from the water supply
RUN is the elapsed pump-on time. RST is the planned pause between cyclic runs in the selected mode. Choose RUN based on how long the source can deliver a steady flow, the space available where the water goes, and the motor maker’s permitted operating conditions. For RST, consider how long the source needs to recover and any minimum time between starts for the motor.
To estimate starts per hour during an uninterrupted cycle, add RUN and RST in minutes and divide 60 by the total. For example, 10 minutes on and 20 minutes off gives about two planned starts per hour. These are example values. Include any separate starts from other controls, power recovery or fault recovery when the installer reviews the motor’s actual start frequency.
Read the protection indication with the operating record
For overload, note the moment the motor stopped and whether it had reached normal running speed. The configured current response can flag a motor, supply or setup problem. For dry run, record whether water reached the outlet and when delivery weakened. An electrician can compare those events with the installed protection setup and water source.
For a voltage indication, record the time and any interruption you observed. Copy the exact characters on the display. Ask the electrician to use the instructions for the installed revision to identify the indication and decide on recovery. If the fault repeats, leave further operation to the electrician.

Send the installer one usable event record
Use the exact model and revision at the top of your note. Add the symptom and the active operating mode. On the next line, put the actual clock time, elapsed motor time if known, the visible indication and the water condition. State what you expected in the same note. If a detail could not be observed safely, leave it blank and tell the electrician.
Avoid resetting first and trying to reconstruct the event later. The display, tank condition or rest period can change once the equipment is stopped or power returns. If the electrician authorizes another watched test, agree on the expected start and stop in advance and keep the same model record. If a breaker trips, a protection indication returns or the panel appears damaged, leave further operation to the electrician.