BOM-F recommended parameter settings cover with the VUKAR starter panel and auto-off timer headline.

Recommended BOM-F Settings: Overload, Dry-Run Protection and RUN Timer

Mohit Vekaria
BOM-F recommended parameter settings cover with the VUKAR starter panel and auto-off timer headline.

BOM-F recommended parameter settings are a first-installation checklist for your exact starter panel and pump. Ask the installer to set the overload and dry-run current limits and their delays, set the high and low voltage limits, and record RUN in minutes for the auto-off timer. Keep the remaining applicable settings at the defaults documented for your controller revision or at the values already approved for your installation.

BOM-F recommended parameter settings checklist for first installation and BOM-F default settings to keep as commissioned.
Have the installer set the first group. Keep the other applicable values at their documented or commissioned settings.

Which BOM-F settings belong on the first-installation checklist?

Start with the BOM-F model and HP variant on the panel label. Note the controller revision from its label or matching manual, and keep the pump nameplate or pump paperwork beside it. The panel model identifies the features. The motor data, supply and site conditions guide the values the installer chooses. A pump with the same HP can still need different settings.

Use the table as a record of what your installer needs to set or confirm. If a menu label on your unit differs, ask VUKAR to identify it from the panel label and a photo of the display. The general controller reference explains the codes, while the manual for your installed revision gives the matching menu and save procedure. VUKAR manuals and parameter reference

Setting What it does What to record
SET · OL and OLT OL sets the overload current limit. OLT sets the delay before the panel trips on high current. Installer-approved OL in amps (A) and OLT in seconds (s).
SET · DR and DRT DR sets the low-current threshold for dry-run detection. DRT sets the delay before a dry-run trip. Installer-approved DR in amps and DRT in seconds.
SET · HIU and LOU HIU and LOU set the upper and lower supply-voltage limits. Both approved limits in volts (V), with the exact menu labels.
CYC · RUN RUN sets the duration of a timed pump run in the applicable auto-off mode. The saved duration in minutes (min), the mode shown on your unit and the observed stop time.

BOM-F overload and dry-run thresholds work with their delays

Read each current limit with its matching delay. OL and DR are current values. OLT and DRT are time values. With overload protection, the panel looks for current above the overload limit for the configured delay. With dry-run protection, it looks for current below the dry-run threshold for its own delay. Changing a current limit changes what condition the panel detects. Changing its delay changes how long that condition must persist before the panel trips.

BOM-F overload and dry-run thresholds paired with their trip delays, with amps and seconds shown.
A threshold sets the current level. The matching delay sets how long the condition must persist before a trip.

If the motor is replaced or the pump begins tripping during a run, give the installer the saved pair, the displayed fault code and the time from motor start to the trip. The installer can compare that record with the replacement motor and operating conditions. A dry-run indication describes what the panel detected. Water supply, pump operation and the installed settings still need to be considered together. Use the VUKAR technical support page if the panel label or fault display needs identification.

BOM-F voltage protection limits belong in the same record

Record HIU and LOU in volts with the pump’s rated voltage and the approved supply conditions. The two limits tell the controller where its high and low voltage protection should act. A reading on the front display shows a supply value at that moment. Keep it in a separate field from the limits the installer approved. If high- or low-voltage trips recur, note the indication and time and have the installer investigate the supply and installation.

VUKAR BOM-F starter panel with RUN auto-off timer controls

VUKAR product

BOM-F Single-Phase Starter Panel

For compatible 0.5–3 HP borewell and openwell pumps that need motor protection and a timed stop. See the product gallery and select the variant that matches the motor.

View BOM-F

Use the BOM-F RUN auto-off timer for a watched stop

RUN is measured in minutes. Select the duration for a supervised run with water available at the source and enough room in the receiving tank. Have the installer confirm the auto-off mode and the save sequence for your controller revision. Reopen the menu after saving and read back the value. Use the normal controls from a dry, safe place and keep the enclosure closed during the test.

BOM-F RUN auto-off timer timeline from reading the saved duration to observing the pump stop.
Read the saved minutes and compare them with the observed stop during a supervised run.

Write down the motor start time and the actual stop time. Note the tank’s starting water level and whether the pump delivered water throughout. The timer uses elapsed run time. A different starting level or flow can change how much water the tank receives in the same number of minutes. If the pump runs beyond the expected stop, use the normal stop control from a safe place and have the installer review the saved setting and selected mode. VUKAR’s guide to auto-off, cyclic and clock timers

Which BOM-F default settings should stay as commissioned?

Use the documented defaults for the controller revision as the starting point for settings outside the checklist. For an installed system, preserve the values your installer commissioned. If TRQ is visible, keep the documented or commissioned value for starting torque time. Keep CTS, current-sensor selection, and current or voltage calibration as commissioned. A qualified installer should handle any change to protection, calibration or restart behavior using the matching instructions.

If the revision shows ATC, ask the installer to document the applicable fault restart delay and what the pump may do after a fault or power return. If registration is required, WRT is the one-time registration entry and uses the code VUKAR issues for the unit. The timed-stop checklist for this BOM-F setup covers RUN. Clock and weekday schedules, float-based tank control, repeating-cycle rest and run/rest memory fall outside that setup. SDT is reserved in the controller reference.

Keep a one-page BOM-F settings record

BOM-F recommended parameter settings record for the panel, saved settings and watched test.
Keep one dated record with the pump paperwork for the next service visit.

Put the panel model, HP variant and controller revision at the top. Add the pump nameplate details, saved mode, the seven setting labels in the table and their units. Under those values, record when the watched test ran, when the motor stopped and any fault indication. Leave space for the installer to note what the pump can do after a power cut or a fault. Keep the record with the pump paperwork so it is easy to find when a motor, panel or water source changes.

What if the settings record is missing?

Ask the installer to read and record the current settings using the matching instructions. Mark each value as “found on panel” until the installer has confirmed it for the pump. This keeps the old values visible while the installer works out what belongs in the new record. Where a reading differs from the earlier paperwork, keep both dated records and ask the installer to explain the change.

What if the pump stops before the saved RUN time?

Write down when it stopped and what the display showed. A stop before the expected time can have a different cause from a normal timer stop. If a protection indication is present, keep the code with the saved limit and delay. When the pump stopped during an outage, record that separately. This gives the installer a useful starting point before another test run or any parameter change.

Electrical installation and wiring are work for a licensed electrical contractor. Arrange isolation and verification of a dead supply before any work inside the enclosure. For the initial installation sequence and product controls, see the BOM-F installation and auto-off timer guide and BOM-F product videos. Central Electricity Authority safety regulations