Illustration of a ceramic workshop with a pump and a separate cleaning-water tank

Water Pump Timer Switch Supplier in Morbi

Mohit Vekaria

Need a Water Pump Timer Switch Supplier in Morbi? If your ceramic workshop can move a cleaning-water tank refill to a different time, compare VUKAR DEV-P2 for a compatible three-phase starter. Check whether your electricity bill charges extra for running at certain hours. Then check that the tank can hold enough water until the new refill time. Compare the small monthly charge you could avoid with the cost to fit the timer.

Identify the Morbi ceramic workshop water pump

The Morbi district administration’s industry history describes Morbi as a ceramics hub. At a tile workshop, list which lines need water when their machines run and which tank refills can move to another time. A separate tank that holds water for routine floor cleaning may have a flexible refill. A pump that serves a machine when it asks for water should follow the machine’s approved controls.

Draw the pipe from the pump to the tank and mark each outlet. Ask the person who runs the shop to check that no other job relies on that refill. Record the tank level before the old run and again before the proposed new run. Use a busy workday for the check. If the tank would reach its low mark before the pump can start, keep the present schedule until the shop has a workable refill plan.

The same 30-minute pump run at 17:15 and 18:30 shown beside an 18:00 peak boundary
Both runs use the same time. Their start times place them on different sides of the evening peak.

Estimate the PGVCL peak-hour pump cost

In the Gujarat regulator’s PGVCL order for FY 2026–27, section 11.3 lists peak hours of 07:00–11:00 and 18:00–22:00 for HTP-1. HTP-1 is a type of high-voltage electricity account. The order lists 45 paise per unit at a billing demand up to 500 kVA. Billing demand is the power demand used for that part of the bill. Ask your bill team to match the account type and rate before using this figure.

Worked example · Count the extra charge on units you can move

Assume the pump draws 6 kW for 30 minutes a day on 20 days. That is 60 kWh. Moving all those units from 18:30 to 17:15 at an extra peak rate of ₹0.45 per unit avoids ₹27 in peak charges for that month. Check your own rate and run.

What the shop finds What to do
The bill has a peak charge and the refill can move Compare the charge you avoid with the fitted cost
The tank would run low before the new time Keep the old refill plan and check tank use
A machine calls for water as it runs Keep the machine’s approved controls

A meter unit is one kilowatt-hour, or 1 kWh. Ask the electrician for the energy used during a usual pump run. A meter reading for that run gives you a better estimate than the HP printed on the motor. Count only the units you can move out of peak hours and multiply by the extra price per unit. Check the result against the installed cost. Other parts of the bill can also change. After you try the new time, compare the old and new run lengths. Note any extra run needed to keep the tank ready. Add its units to the new plan before you compare the actual charges.

When a three-phase clock timer switch fits

The VUKAR DEV-P2 product page lists a clock timer for a compatible three-phase starter. A clock timer can start or stop a pump at set times. Ask the electrician to verify the starter and check whether the tank can still stop the pump when it is full. Have the team show what happens if a power cut causes a missed run. Keep a way to restore the required water supply under the shop’s approved plan.

What to send for a Morbi pump timer quote

Send the motor and starter labels, the usual run time, the new time you want and the tank’s low and full controls. Ask for the switch and fitting prices separately. Give your delivery PIN code. If the monthly charge you can avoid is small, check whether the same purchase also solves a real staff scheduling problem.

Read the guide to pump timer types, then send VUKAR your motor and refill plan for a compatibility check.

Back to blog