Water Pump Timer Switch Supplier in Solapur
Mohit VekariaShare
If you need a Water Pump Timer Switch Supplier in Solapur, compare VUKAR DEV-P2 for an existing compatible three-phase farm pump starter. Start by putting the feeder hours and the planned pump hours side by side. A timer can ask a pump to run, but the pump needs power at the same time. If the two windows only partly overlap, the farm tank can receive less water than the clock setting suggests.
Why Solapur farm feeder hours matter
MSEDCL’s agricultural feeder circular identifies Hannur and Manegaon substations in Solapur district and gives daytime schedules for listed outgoing feeders. A feeder is the power line that serves a group of connections. The circular covers those named lines at the time of the notice. Check the current schedule for your own connection. A nearby farm may be on a different line, so its clock setting may give your pump a shorter run.
Write down the start and end of available power for the days you need the tank filled. Then write the time by which you want water ready. If your tank feeds drip lines, the example here deals with filling the tank. Work out drip watering time separately. If the farm uses a standalone solar controller or a variable-speed drive, show it to the electrician before asking for a switch for an existing starter.

When a three-phase pump clock timer fits
A clock timer sets a time of day to run. A cyclic timer repeats an on period and an off period. The VUKAR DEV-P2 product page lists both modes for compatible three-phase pump applications. Choose clock timing if you need one refill period within the confirmed supply window. Choose repeat timing if the job needs several runs and rests. Ask which mode should take charge if both are available on the same switch.
Worked example · A 30-minute setting with 20 minutes of power
Assume supply ends at 16:00. A timer requests 15:40 to 16:10. At 30 litres per minute, a 30-minute run would move 900 litres. The 20 available minutes could move up to 600 litres at the same rate. Actual delivery depends on the pump and stop settings.
| Time to check | Sample values |
|---|---|
| Power still available | Until 16:00 |
| Timer requests a run | 15:40 to 16:10 |
| Both conditions overlap | 20 minutes, up to 600 L at 30 L/min |
Also decide what happens if power returns after a scheduled start. Ask the installer to test the exact settings on your panel. It may matter whether the return falls inside or outside the allowed run window. Tell the installer if someone must check the pump before it starts again. Keep the tank-level and low-source stop rules in the job request because timing alone does not measure water.
How to work out pump runtime overlap
The overlap is the part of the timer window that falls inside available power hours. In the example, you have 20 minutes of overlap. Measure the actual flow at the tank inlet. At a steady rate, multiply litres per minute by available minutes to see how much could arrive. A level stop, lower flow or a restart setting can reduce that amount. Compare it with the usable water already in the tank before changing the time. On the first few runs, record the clock setting, the actual start and stop and the tank level at the end. If the tank is still low, that record shows whether the cause was less power time or lower flow.
What to send for a Solapur timer quote
Send the pump nameplate, starter label, current feeder schedule, planned pump hours and approximate litres needed per refill. Note how the tank stops a run when full and who checks a low water source. Ask the installer to demonstrate a normal start, a loss of power mid-run and a power return after the planned end. Ask the supplier to list the switch, any parts for level stops, fitting and tests separately. Include the delivery PIN code for a dispatch estimate.
Open the three-phase digital auto switch comparison, then send the pump plate and the two time windows to VUKAR. Ask for the exact model and a test plan for your starter.