Automatic Water Level Controller Supplier in Nashik
Mohit VekariaShare
If you’re searching for an Automatic Water Level Controller Supplier in Nashik, SubmersibleShop.com offers VUKAR DEV-G2 for compatible three-phase openwell or monoblock pump circuits. After power returns, a building's transfer pump should still wait if its lower tank is low. Ask for a separate test of the tank-level stop, the start delay after power comes back, and the overload lockout.
Nashik water and power recovery can take different paths
Nashik Municipal Corporation's water supply report describes how water from Gangapur Dam is pumped toward treatment plants for several parts of the city. On 3 June 2026, The Times of India reported a power failure at the Gangapur pumping station that disrupted city water. The building's electrical supply and the city pump's electrical supply serve different equipment. So note when power returns at your building and when water reaches your lower tank. Nashik Municipal Corporation water supply report June 2026 Gangapur outage report
Keep three readings in the building log. Note when the pump panel lights up, when the lower tank reaches its safe pump level, and whether the roof tank needs water. Read the panel from outside and use the tank indicator or safe gauge. If power is back but the lower tank stays low, find out whether the tank is filling before you change the controller's delay.

Pump restart after a power cut and the start delay
A start delay is a wait after power returns. DEV-G2 lists an adjustable delay for that event. It also has two float inputs. A float is a switch that moves when water rises or falls. With a suitable setup, one float tracks the lower tank and the other tracks the upper tank. Ask the electrician to demonstrate that the pump stays stopped while the lower tank is below its safe level, even after the delay has passed.
Worked example: the delay ends before the tank fills
Assume power returns at 7:00 and the one-minute start delay ends at 7:01. The lower tank reaches the safe pump level at 7:20. That leaves 19 minutes when the time check has passed but the water check has not. The installer should show that the pump stays off in those 19 minutes. The times are for this example.
| What the panel sees | Expected result to verify |
|---|---|
| Power returns, source tank still low | Pump stays off after the start delay. |
| Source ready, upper tank full | Pump stays off. |
| Overload lockout active | Check fault and follow the manual reset procedure. |
Then have the electrician show a permitted start with normal power, enough water in the lower tank and room in the upper tank. Ask what will happen if the lower tank refills after the delay has already ended. The exact response depends on the installed mode and wiring. If the upper tank is already full, it should also keep the transfer stopped. DEV-G2 timer, float and protection features
Low tank and overload stops mean different things
A low lower tank is a water-level stop. An overload means the motor draws more current than its set limit. DEV-G2 lists a lockout after overload that requires a manual reset. It also lists a separate retry delay for a detected dry run, when a motor is running without adequate water. Have the electrician explain the display and reset procedure. Use the maker's approved checks. Avoid deliberately running the pump dry or causing a fault to test it.
Nashik controller installation quote and handover
Send the motor plate photo, current starter details, and a sketch of the lower and upper tanks. Include the proposed float locations and describe whether the pump may restart while nobody is in the pump room. Ask the electrician to record the chosen mode, the start delay, both float stop tests and the action after an overload. Keep the handover note near the panel where the building team can find it.
Compare VUKAR three-phase water level controller models. Then send your pump details and restart needs and ask for a quote that includes those handover checks.