Automatic Water Level Controller Supplier in Chennai buying guide featuring the VUKAR DEV-G2.

Automatic Water Level Controller Supplier in Chennai

Mohit Vekaria

When comparing an automatic water level controller supplier in Chennai for a tanker-fed building, consider VUKAR DEV-G2 after you check the free space in the sump and how the roof tank stops the pump.

Check the receiving sump before a tanker unloads

Chennai Metro Water’s charter describes its Dial for Water booking service. A state municipal report separately documents distribution by lorry and monitoring of tanker trips. Use the booking or delivery information to organise the receiving person, then check the actual sump capacity at arrival. Tanker arrival and your pump’s transfer to the roof are separate jobs. If the roof tank is already full, do not count on the transfer pump to make space while the tanker is unloading.

Chennai Metro Water citizen charter · Tamil Nadu municipal water report

One arrival, two separate capacity checks

Picture a tanker arriving when the sump has 2,000 L of free space. A roof tank that can accept another 500 L does not automatically add that space at the tanker inlet. Agree who checks the sump before unloading and what the pump does when the roof tank reaches full.

Condition What to agree
Tanker arrives Check free sump volume before accepting the load
Sump low Demonstrate how the transfer pump should respond
Roof tank full Demonstrate the upper tank stop

Before you order

Draw the water route before you label the signals. Mark the source, the pump, the receiving tank and any other inlet. On the drawing, put a mark where each level sensor is meant to act. Ask the installer to show what happens if water is low at the source while the receiving tank still needs water. Then ask to see what happens when the receiving tank is full. If another inlet can still fill the tank, give that inlet its own stop decision. This drawing also shows the supplier the cable route and which signals actually belong on the quotation.

Related guide · Automatic Water Level Controllers for Tank Filling

VUKAR DEV-G2 product detail
VUKAR DEV-G2 product detail

Product and quote

Send the two tank sizes, float positions and motor plate. Ask the electrician to show both the low-sump stop and the roof-full stop, and ask the supplier to price the two floats and any additional cable separately.

Compare the installed job, using the same scope for each seller. Ask for the exact model and variant, the included parts, the cost of field cable and any mounting work. Ask who supplies the sensors and who returns if a setting needs correction. A lower panel price can leave out the part of the job that brings the pump back into service. Write the test you expect alongside the price. That makes it clear whether one supplier has quoted equipment only and another has also included fitting, setting up the controls and demonstrating them to the person who operates the pump.

Put a short operating card beside the pump log. Give the pump a name that matches its label on the drawing. Write the usual start condition, the normal stop and the name of the person who can approve a change. Leave room to record the time, the tank state and any alarm before someone clears it. During handover, have the regular operator explain the sequence back to the installer in their own words. If the two descriptions disagree, resolve that difference while the installer is still there. Keep the model number and the accepted test result with the card.