VUKAR DEV-N Digital Auto Switch: Installation and Cyclic Timer Settings
Mohit VekariaShare
For a DEV-N 3 phase digital auto switch setup, identify the compatible three-phase starter circuit and use the DEV-N diagram before setting the cyclic timer. Have a licensed electrical contractor install the equipment and check the protection settings using the instructions for the installed revision.
DEV-N installation and equipment match
Read the motor nameplate and identify the existing starter. Record phase, rated voltage, motor HP and operating current. Give the installer the starter make, model and available control-circuit documentation. These details help establish whether the auto switch and the existing motor-switching equipment can be used together.
VUKAR lists DEV-N for compatible three-phase starter circuits with motors from 2 to 100 HP. Confirm the starter circuit and sensing arrangement before purchase or installation. DEV-N specifications and options
Confirm which equipment switches the motor power and which circuit carries the run command. A contactor is the electrically operated motor switch. The electrician should check the device’s current-sensing arrangement, control voltage and connection diagram for the particular starter before energizing.
Have the installer verify protective earthing, isolation and circuit protection. The supply must be isolated and verified off before anyone opens an enclosure or handles conductors. The electrician should check the phase conditions and verify normal motor operation before handing over automatic control. Central Electricity Authority safety regulations

DEV-N cyclic timer settings
The model documentation describes RUN and RST in minutes. It also distinguishes the normal cycle from the recharge wait after a dry-run event. Match the device and current-sensing revision to the supplied manual before applying the button sequence or entering numerical settings.
Choose an initial run period from the water source and the pump maker’s operating limits. Observe whether water delivery remains steady toward the end of a normal run. Ask the installer how much rest the source and motor need, including any limit on starts per hour. Use those observations to agree on the first watched test.
The DEV-N reference identifies RUN for the operating period and RST for the rest period in minutes. The wiring guide covers DEV-N starter connections. Have the installer match the current-sensing arrangement and controller version to the supplied instructions before using any button sequence or entering a value.
Read back the saved run and rest durations with their units. The cycle begins and ends according to the installed operating mode. Watch the pump stop, time the rest from the actual stop, and stay for the next permitted start. That gives you evidence for both intervals. VUKAR timer types guide
If the motor stops before the intended time, note the display and the condition of the source. A protection stop, a stop from another control and a normal timer stop require different checks. Leave the running values in place while the installer investigates the reason for an unexpected stop.

How to use DEV-N after installation
At handover, compare what the device shows with what the starter and motor actually do. If a control signal changes and the contactor does not respond as expected, record both observations. The electrician can check the control path before any timer setting is changed.
Before the watched test, confirm that water is available and the receiving point can accept it. Keep the enclosure closed and make sure the normal stop control is safely accessible. Agree on what counts as a successful run before you enable automatic operation.
- Confirm the saved settings. Read the active mode and relevant values with the installer. Record what should permit a start and what should end the run.
- Observe the motor response. Confirm a permitted automatic start, the timed stop and the next permitted restart. Record the display and the contactor response at each transition.
- Verify recovery behavior. Ask the installer to document what happens after power returns or a protection condition clears. A permitted automatic restart can occur without a new button press.
- Keep a handover record. Record the DEV-N label, supply, motor rating, wiring reference and actual test results together.
What to record during commissioning
- Start of run
- Record the active mode, actual start time and whether water reaches the delivery point.
- End of run
- Compare the stop time with the saved interval and record whether delivery remained steady.
- Rest period
- Measure from the actual stop. Record the display and the source condition if it can be checked safely.
- Next permitted start
- Confirm the observed restart matches the saved rest duration and the operating rules for the site.
Observe each transition from a dry and safe location. If the actual response differs, record what the display, starter and pump each did. The installer can then trace whether a setting, an input, a protective condition or the motor circuit determined the outcome. DEV-N model connection diagram
Trace the start request through the existing starter
Ask the electrician to record where the auto switch enters the starter control circuit and which local controls can stop the motor. With the enclosure closed, observe a normal start and stop. Read the controller state and then verify the motor response. If they disagree, the installer can use the circuit documentation to locate the point that needs checking.
Record the current range and sensing arrangement
Write down the installed device code, the motor nameplate current and the normal running value observed during the test. Have the electrician confirm the current-sensing hardware for that revision and check that the display is consistent with the actual installation. If the motor or starter is changed later, recheck the combination before reusing the earlier settings.
Agree on recovery after an interruption
During handover, ask which states allow another run after a stop or power loss. Keep the approved mode and any waiting period in the record. The operator should know whether to expect a restart when a timer becomes eligible and which control must be used when the equipment needs to stay stopped for service.
Revisit the cycle when delivery changes
A pump can still run for the programmed interval while delivering less water than expected. During each inspection, note how delivery behaves near the end of the run and whether the source is ready at the next start. Review those observations with the installer before extending an interval or increasing the number of starts.
DEV-N troubleshooting after an unexpected stop
Read the display and note the elapsed run time, water delivery and the condition that preceded the stop. On applicable VUKAR controllers, FOL indicates overload, FDR indicates dry run, and HIU or LOU indicates high or low voltage. If a fault returns, have the cause diagnosed before another run. VUKAR fault-code guide
Record any phase-related indication as displayed. The electrician should investigate the supply and phase conditions before changing timing or protection. Use the installed model’s reset procedure after the fault has been addressed.

How do I decide whether the rest duration is still suitable?
Watch whether water delivery stays steady through the run and whether the source has recovered before the next start. Review the values with the installer when the source conditions or pump change.
When a pump, starter, float or water source changes, give the installer the previous commissioning record. Have them recheck the expected sequence and verify the changed installation before relying on automatic operation again.
Before the system is left on automatic
Review the normal start, normal stop and recovery behavior with the person who uses the pump. Keep the approved settings near the controller or in the site records. Where another control also affects the pump, identify its role and record who should be contacted if the motor responds differently from the documented sequence.
Record an unexpected event while it is fresh
If there is an unexpected stop or a delayed start, write down the time, the visible display and what the pump was doing. Also note any recent power interruption or change to the water source. Keep those details with the equipment model so the installer can check the relevant setting and conditions.
Recommended DEV-N Settings: Cyclic RUN/RST and Motor Protection