TDS Meter Reading Guide: Compare Borewell, Tank and Tap Water
Mohit VekariaShare
Use a TDS meter to compare dissolved solids at the borewell outlet, tank outlet and tap. Take the samples close together, use the same meter setting and wait for each reading to stabilise. The readings can show a change along the water route. To assess drinking-water safety, ask a laboratory for the relevant microbiological and chemical tests.
Take readings you can actually compare
A typical handheld TDS meter estimates total dissolved solids from electrical conductivity. The conversion factor, temperature compensation and instrument condition can affect the result. Compare samples using the same meter, mode and units, with calibration checked according to the manual.
- Label three clean cups. Write source, tank and tap. Collect samples close together and record the time, any source change and the treatment at each point.
- Rinse and measure. Rinse the probe as the manual directs between samples. Use separate cups, wait for a stable reading and record the unit shown. Keep EC readings in µS/cm separate from TDS readings in ppm.
- Repeat an unexpected result. Rinse again and take a fresh sample. If the result still differs, verify the water route and source history before interpreting it.
Hanna meter manual and calibration guidance · WHO fact sheet on total dissolved solids

Worked example with three sampling points
Swipe sideways on smaller screens to see more columns.
| Sampling point | First / repeat | What to investigate |
|---|---|---|
| Borewell outlet before storage | 620 / 618 ppm | Use it as the source reading for that sampling session. |
| Tank outlet before treatment | 480 / 482 ppm | Check whether the tank held water from an earlier fill or a second supply. |
| Kitchen tap before treatment | 475 / 477 ppm | Check whether the tap is supplied by this tank. Compare the size of the difference with meter repeatability and the manual. |
These example numbers suggest a difference between the source and tank at the time of sampling. They do not identify the cause. Repeat when you know which water entered the tank. For purifier performance, take a separate pair immediately before and after treatment and compare it with the manufacturer’s service criteria.
Choose the test that answers your question
Swipe sideways on smaller screens to see more columns.
| Your question | What to request |
|---|---|
| Is the water suitable to drink? | Ask a water-testing laboratory which microbiological and chemical parameters apply to your source. Ask about E. coli, nitrate and fluoride where relevant. |
| What could be causing scale? | Ask for a hardness test. Compare the reported calcium and magnesium-related hardness with the application requirements. |
| Did my treatment change the dissolved solids reading? | Compare paired readings taken before and after treatment under the same conditions. Use the treatment supplier’s guidance for interpreting the change. |
For a laboratory sample, ask the lab for its container, collection and transport instructions before collecting it. Microbiological samples need the lab’s specified sampling process.
Jal Jeevan Mission water-quality testing framework · Find a water-testing laboratory through JJM
Copy this three-sample worksheet
Swipe sideways on smaller screens to see more columns.
| Point | Time and unit | First / repeat | Source or treatment notes |
|---|---|---|---|
| Borewell outlet | ________ | ________ | ________ |
| Tank outlet | ________ | ________ | ________ |
| Tap | ________ | ________ | ________ |
Write the meter model, calibration date and selected mode above the table. Save the readings alongside any laboratory report and note when the tank was filled.
Check the tank’s usable capacity and fill time
Quick answers
Can I compare one reading from a TDS meter and another from an EC meter?
Compare readings in the same mode and units. An EC reading in µS/cm and a TDS estimate in ppm represent different quantities.
Does a low TDS reading establish that water is safe to drink?
Drinking-water safety requires appropriate microbiological and chemical checks. A handheld TDS reading alone cannot establish it.