Tank Reading Wrong or Pump Stops Early? BOM-W Level Display and RUN Timer Checks
Mohit VekariaShare
If a BOM-W tank level display reading looks wrong or the pump stops early, log the actual tank level, the reading and the run duration separately. Record the visible MCB state as a fourth observation when it can be seen without opening a cover.
Start with the installed unit
Record the model and revision from the label, the motor nameplate and the active mode. Similar panels can have different menus. Use the installed revision’s guide for any setting, its units and the behavior of the selected mode.

Use a separate record for the level indicator
Record the displayed tank state and the real water level from a safe location. Use two observations at different levels when that is practical and safe. Write down the time of each reading, whether the pump was running and what the display showed. If the real level changes while the indicator stays the same, give the readings to the installer. Keep the sensor connections and panel cover undisturbed during this observation.
This model’s level display is an indicator. The controller does not use that reading as its automatic fill command. Keep the evidence for the indicator separate from the evidence for a motor stop. For a timer-related stop, use the approved duration and elapsed motor time. For a visible protection or breaker event, record exactly what changed. A display that says full by itself does not explain a stop on an indicator-only starter.
A worked example for this model (BOM-W)
The BOM-W pairs a level indicator with a timed stop and an MCB. A display mismatch can exist during a normal stop at the saved RUN. A visible MCB trip is a separate event. For example, if the tank still needs water, the display is unchanged and the breaker has visibly tripped, record all three and leave diagnosis to the electrician. Keep the timer unchanged while the cause is assessed.
What an auto-off timer can tell you
In the timed-stop mode, RUN is the planned time from an accepted start to the automatic stop. Use the unit’s manual and the approved settings record to confirm which mode is active. If the pump finishes a normal timed run, the display and the actual elapsed time should agree with what the installer recorded for that mode. Keep that example as the normal reference.
If the stop occurs at different points on different runs, make a short log for each event. Include the saved RUN, actual elapsed time, any displayed indication and whether water had reached the outlet. A repeated protection stop needs diagnosis. The timer reading helps the electrician identify the expected stop time while they review the event that interrupted it.
Follow the command to the pump
A controller can show a request while the motor is still off. A starter switches motor power when the control circuit permits it. Observe the display, the starter’s visible response and water delivery as separate facts. These observations give the electrician a place to start without asking you to open the enclosure or touch conductors.
If the display shows that the pump should be running but there is no water, write down whether you could see or hear the motor run from a safe location. If the motor runs but delivery is absent or weak, record how long it ran and when the flow changed. Keep the display photo and the times together so the installer can compare them with the actual settings.

Use the motor and supply limits
Have the electrician match the motor’s nameplate and the controller’s sensing arrangement before setting overload, dry-run or voltage protection. A setting copied from a different pump can be unsuitable even when the pumps have the same horsepower. Ask the electrician to record the approved values, their units and which manual or measurement they used. Keep the previous approved values in the record if a setting needs to be changed.
Observe normal operation from a dry and safe place with the enclosure closed. Changes to wiring, live measurements, current sensing, protection and automatic restart belong with the installer. If a fault reappears, record the indication and stop using automatic operation until the cause has been assessed. Use the product instructions and the applicable electrical safety rules for installation and service.
Separate an MCB trip from a controller stop
An MCB is a miniature circuit breaker. A visibly tripped breaker and a motor stopped by the timer are different observations. If an MCB is fitted and its state can be seen without opening a cover, record whether it changed and what the controller display showed at the same moment. If the breaker trips, leave diagnosis to an electrician.
A controller can stop the motor while the circuit breaker stays in its normal position. A timer can also end a normal run with the breaker in that position. Use the elapsed time, the active mode and any visible indication together. When the breaker or a protection indication returns, save the observations for service before another attempt to run the pump.
Prepare the installation for a watched test
Choose a time when the source has water, the receiving point has room for delivery and the operator can observe from a safe place. Agree with the installer on what counts as a successful start and stop. Use the normal operating controls. Have the installer handle any changes to the electrical circuit or protection settings.
Tell everyone working near the pump when an automatic start could occur. Keep the enclosure closed while observing the display. If the observed behavior differs from the manual or the approved record, stop the test in the normal safe way and write down what happened before any values are changed.
Read the protection indication with the operating record
For overload, note the moment the motor stopped and whether it had reached normal running speed. The configured current response can flag a motor, supply or setup problem. For dry run, record whether water reached the outlet and when delivery weakened. An electrician can compare those events with the installed protection setup and water source.
For a voltage indication, record the time and any interruption you observed. Copy the exact characters on the display. Ask the electrician to use the instructions for the installed revision to identify the indication and decide on recovery. If the fault repeats, leave further operation to the electrician.
What to record for service
| Actual condition | Water level or delivery and the visible operating state. |
|---|---|
| Expected behavior | The active mode, approved timer value or documented switch point. |
| Evidence to send | Timestamp, visible display and what the motor actually did. |

Change one condition between watched tests
Begin a test with the mode and relevant settings written down. Change one approved timing or operating condition at a time with the installer. Then observe the pump from the start permission through the actual stop. If two settings change together, a normal or unexpected result is harder to explain later.
Keep the physical tank level and indicated level in one record. Put elapsed motor time and the observed stop in a second line. If a difference repeats, compare both records with the approved timed-stop value before requesting a setting change.
Send the installer one usable event record
Use the exact model and revision at the top of your note. Add the symptom and the active operating mode. On the next line, put the actual clock time, elapsed motor time if known, the visible indication and the water condition. State what you expected in the same note. If a detail could not be observed safely, leave it blank and tell the electrician.
Avoid resetting first and trying to reconstruct the event later. The display, tank condition or rest period can change once the equipment is stopped or power returns. If the electrician authorizes another watched test, agree on the expected start and stop in advance and keep the same model record. If a breaker trips, a protection indication returns or the panel appears damaged, leave further operation to the electrician.
Can I use an older service note for comparison?
An earlier note helps when it names the same installed revision, mode and source conditions. Keep it next to the new record and mark any changes, such as a repaired pipe or a different water source. Give the electrician both dates and identify which details you observed directly.