Tank Pump Misses Its Schedule? TPB-T Clock and Tank-Level Checks
Mohit VekariaShare
If the TPB-T tank pump is not starting on schedule, record the saved clock event, the single float’s tank request and the borewell motor state at the same time. A clock event and a tank request are two different observations. The active mode and any protection state explain how they apply together.
Start with what the display shows
| Visible state | What it can mean and what to do |
|---|---|
| Scheduled time passes while the tank needs water | Record the panel time, day, mode and visible tank request together. Compare them with the approved schedule. If the installer authorizes a watched test, record when both the documented timing and level conditions are met. |
| The display suggests operation, but water is absent | The command and water delivery are separate observations. Note whether the motor actually ran and whether water reached the usual outlet. Report the first missing response. In a supervised return to service, confirm both the motor response and steady delivery. |
| An unfamiliar indication, an unexpected stop or a visible trip | Record the exact characters or lights, the time and the motor state from outside the closed enclosure. Leave protection values as commissioned. If the stop repeats or a breaker has tripped, leave further operation to a qualified electrician. |
Start with the installed unit
Record the model and revision from the label, the motor nameplate and the active mode. Similar panels can have different menus. Use the installed revision’s guide for any setting, its units and the behavior of the selected mode.

Catch the missed event while it is happening
Take one observation at the intended clock time and another when the pump eventually starts, if it does. In each observation record the displayed time, actual time, enabled day, selected mode and what the controller showed. A report that the motor was off at breakfast leaves out whether the clock was wrong, the event was disabled, a rest was still running or protection was active. The two observations give the installer something to compare.
Keep the previous stop in the same log. If the motor ran before the missed event, the elapsed pause and the event time describe two different clocks. Ask the installer whether the selected mode accepts that event while a rest is active. If the setup also uses tank control, add the real tank level and request. Record only conditions that the installed model supports. Use one controlled test event and leave overlapping events and approved protection values alone during the test.
A worked example · TPB-T
At 06:00 the overhead tank is low. Suppose the visible indication and the installer’s record agree that the float is requesting water, yet the motor remains off. Write down the displayed clock time and active day, the selected mode and the motor state. If the tank first calls at 06:20 instead, put that on another line. The electrician can use both timestamps to determine which rule governed that start.
Set the clock before using a schedule
A clock event uses a time of day, such as 06:00. RUN and RST are elapsed durations, such as 10 minutes. Read the displayed time, weekday and enabled days together. A saved event can show the correct time yet remain inactive because the wrong day or mode is selected. Begin with one event the operator can safely observe.
Watch the opening and closing of the first window and record the actual behavior. If a pump is already running near closing time, use the installed revision’s instructions to determine how that mode handles the boundary. Write down whether it stopped, completed the current run or waited for a later permission. Test the specific sequence before adding overlapping events or leaving it unattended.
Separate a request from permission to start
A low tank can create a request before a clock window opens. Depending on the selected mode, a start can also depend on the state of the water source, any cyclic rest period and protection. Write each condition in a separate line of the event log. That makes it easier to find the actual reason for a delayed start.
Where the controller offers separate operating windows for water-level and cyclic modes, label each saved window by its purpose. Test inside and outside the relevant window with the installer. Ask them to record how your revision treats a low tank at closing time and what it will do when another window opens.

Keep supply events separate from the timer
On this three-phase model, a supply or phase-protection indication is a separate event from the end of a scheduled run. Record the indication as it appeared, its time and whether the pump was already running. A missing or unstable phase can require qualified diagnosis even when other equipment nearby has power. The electrician can compare the incoming supply, phase sequence and the installed protection settings against the approved record.
A changed indication can help the electrician decide where to measure. It cannot identify which wire or connection needs work. Keep the panel closed and leave tests of phase voltage, sequence and current to a qualified person. If the pump stops repeatedly or the breaker trips, leave further operation to the electrician. Give them the model, the motor nameplate and the exact time of the event.
Read the real water level and the controller state
Mark the observed low and full switching points with the installer while the sensor is in its normal installed position. Write down the physical water level, the state shown on the controller and when the motor actually starts or stops. If those three observations disagree, keep the evidence and ask the installer to review the level input and the selected mode.
A level sensor can report that the receiving tank needs water. The start can still depend on source conditions, timing and protection. During a supervised test, observe a valid request and the documented full-level stop. If there is a source input, ask the installer to demonstrate its low-water response using the prescribed method while keeping the pump protected.
Use the motor and supply limits
Have the electrician match the motor’s nameplate and the controller’s sensing arrangement before setting overload, dry-run or voltage protection. A setting copied from a different pump can be unsuitable even when the pumps have the same horsepower. Ask the electrician to record the approved values, their units and which manual or measurement they used. Keep the previous approved values in the record if a setting needs to be changed.
Observe normal operation from a dry and safe place with the enclosure closed. Changes to wiring, live measurements, current sensing, protection and automatic restart belong with the installer. If a fault reappears, record the indication and stop using automatic operation until the cause has been assessed. Use the product instructions and the applicable electrical safety rules for installation and service.
Read the protection indication with the operating record
For overload, note the moment the motor stopped and whether it had reached normal running speed. The configured current response can flag a motor, supply or setup problem. For dry run, record whether water reached the outlet and when delivery weakened. An electrician can compare those events with the installed protection setup and water source.
For a voltage indication, record the time and any interruption you observed. Copy the exact characters on the display. Ask the electrician to use the instructions for the installed revision to identify the indication and decide on recovery. If the fault repeats, leave further operation to the electrician.

Send the installer one usable event record
Use the exact model and revision at the top of your note. Add the symptom and the active operating mode. On the next line, put the actual clock time, elapsed motor time if known, the visible indication and the water condition. State what you expected in the same note. If a detail could not be observed safely, leave it blank and tell the electrician.
Avoid resetting first and trying to reconstruct the event later. The display, tank condition or rest period can change once the equipment is stopped or power returns. If the electrician authorizes another watched test, agree on the expected start and stop in advance and keep the same model record. If a breaker trips, a protection indication returns or the panel appears damaged, leave further operation to the electrician.

Compare like-for-like observations
Use the normal operating record from this installation as your baseline. An older record is useful when it lists the same model revision, selected mode and operating conditions. Put that record beside the new one and mark changes such as a repaired pipe, a different outlet or recent starter service. Note who observed each event and whether the time was measured or recalled.