Kochi home illustration with a public line feeding a sump and a separate pump lifting water to the roof tank

Control Panel Supplier in Kochi

Mohit Vekaria

Tell your control panel supplier in Kochi which tank overflows and whether the pump is running at the time. If the ground tank overflows while the pump is off and water keeps entering through the inlet, ask a licensed plumber to check that inlet valve first. If the pump keeps filling a full roof tank, have an electrician check its stop signal. Compare the VUKAR MOA-B when that pump needs a new starter and matches the model.

What to check for sump overflow in Kochi

A Kerala State Planning Board study of Kochi Municipal Corporation described homes that first store water in a sump and then pump it to a roof tank. A sump is a tank at or below ground level. In a home with this two-step layout, an overflow from the sump may come from the inlet even with the pump off. Start by looking at which tank is spilling and which pipe is still delivering water, from a dry place you can reach safely. Read the Kochi case study, section 5.5.2.

Tell the plumber if the water comes out of the sump overflow pipe while the inlet is still flowing. Ask them to check the inlet valve and whether the overflow pipe can carry water away. The Kerala Water Authority says alterations to an existing installation require the approval of its Assistant Executive Engineer and must be arranged through a licensed plumber. Ask the plumber whether the job is a valve repair or an alteration. See the Kerala Water Authority alteration process.

Separate mechanical sump inlet valve and electrical roof tank float switch shown on two water tanks
Illustration. The sump inlet valve and the roof tank float switch control different things.

What the roof tank float switch does

A mechanical float valve can close the pipe that fills a sump when the tank is full. Its float rises with the water and moves the valve. A roof tank float switch works with electricity. It sends a signal to the pump panel when the water reaches a set level. Think of the inlet valve as a tap that controls water entering the sump and the switch as a signal for the pump.

Worked example with two spill reports

Say a home has a 1 HP pump and a 500 L roof tank. In the first report, the pump is off and water still enters the sump until it spills. Ask the plumber to check the inlet. In the second report, the sump is fine and the pump keeps running as the roof tank spills. Ask the electrician to check the upper float and panel. The ratings describe an example.

What you observe First person to call
Sump overflows with pump off and inlet flowing Licensed plumber to check the inlet valve
Roof tank overflows while pump runs Electrician to check the full-tank stop
Roof tank keeps receiving water with pump off Plumber to trace the water path

If the roof tank spills while the pump runs, ask the electrician to check whether the float moves freely and whether the panel receives the full-tank signal. If water keeps entering the roof tank when the pump is off, have the plumber trace that flow before you order a starter. Ask the electrician to show that a full tank now stops the pump after any repair.

When a single-phase monoblock starter fits

A monoblock, also called a Tullu pump, has its motor and pump in one unit. The VUKAR MOA-B listing gives options from 0.5 HP to 3 HP for compatible single-phase monoblock pumps. It describes a supplied cable float switch for automatic filling, plus dry-run protection. Dry run means the pump runs with too little water. Have your electrician match the motor plate and demonstrate the start and stop settings. If the current panel works and the switch alone has failed, ask whether a compatible switch is enough.

What to send for a pump control panel quote

Send a photo of the motor plate, the existing panel label and a sketch showing the tank that spills. Write down whether the pump was running and whether you could see water entering. Ask the electrician to quote the float, starter and installation as separate items. That makes it easier to see when a small repair solves the fault. Ask the plumber to show the inlet closing and the electrician to show the pump stopping at the agreed level.

Start with the single-phase monoblock starter comparison. If you know the layout and pump rating, send them to VUKAR support to check the model.

Back to blog