Borewell Handover Guide: What to Check Before You Pay or Buy a Pump
Mohit VekariaShare
Before you pay for a borewell or order a pump, ask for a written drilling record and a measured pumping test. Get the actual depth, casing details, water level before and during pumping, flow and test duration. These readings help you compare what you paid for and give your pump supplier the information needed to size the system.
Compare the total quote on the same scope
Ask both contractors to quote the same bore diameter, drilling depth, casing material and grade, casing length and test scope. Check whether the drilling rate changes with depth. Ask them to write down what you owe if the bore is dry, if drilling stops early or if you approve additional depth.
Swipe sideways on smaller screens to see more columns.
| Charge | Quote A | Quote B |
|---|---|---|
| Drilling | 250 ft × ₹90 = ₹22,500 | 250 ft × ₹105 = ₹26,250 |
| Casing | 60 ft × ₹340 = ₹20,400 | 60 ft × ₹290 = ₹17,400 |
| Mobilisation | ₹3,500 | Included |
| Same agreed pumping test | ₹4,500 | ₹2,500 |
| Comparable total before tax | ₹50,900 | ₹46,150 |
In this illustration, Quote B costs ₹4,750 less despite the higher drilling rate per foot. The figures are examples. Ask each contractor to confirm GST, bore development, test equipment, transport and dry-bore charges in writing.
Read the pumping test before you buy the motor
Have the driller or tester record all depths from the same reference point. Ask for the flow and water level together, along with test duration and water-level recovery after stopping. A qualified tester can interpret whether the readings support your planned use.
Swipe sideways on smaller screens to see more columns.
| Reading | Example | What you learn |
|---|---|---|
| Total drilled depth | 250 ft, about 76.2 m | The depth of the hole. |
| Static water level | 16 m below ground reference | Where the water stood before pumping. |
| Pumping water level | 26 m below the same point at 60 minutes | The level while pumping at the recorded test flow. |
| Test discharge | 18 L/min | The flow achieved during the test. |
| Recovery | 18 m below reference, 20 minutes after stopping | How the water level moved back after this test. |
Here, drawdown at 60 minutes is 26 − 16 = 10 m. This example shows how to read a record. Ask your tester whether longer or seasonal testing is needed for your expected daily use.
Central Ground Water Board pumping test overview

Turn the test into a pump brief
Example for a 1,000 L overhead tank
At a steady delivered 18 L/min, fill time is about 56 minutes
If the pumping water level is 26 m below the reference and the tank inlet is 6 m above it, the vertical lift is 32 m. Add an illustrative 4 m of pipe and fitting loss at the target flow and the duty point is 18 L/min at about 36 m of head, assuming free discharge. Ask the supplier to show this point on the pump curve.
Confirm the final pump setting, bore diameter and clearance, operating water level, required flow, cable length and available electrical supply with the installer. Use the supplier’s pump curve and motor nameplate when selecting the starter.
Calculate total pump head · Check tank capacity and fill time
Printable borewell handover record
Print this section or copy it into your work order. Ask the driller and tester to complete and sign it. Keep the readings with the final invoice and pump quotation.
Swipe sideways on smaller screens to see more columns.
| Record | Fill in at site |
|---|---|
| Site, date and contractor | ________________________________ |
| Drilled depth, diameter and reference point | ________________________________ |
| Casing material, diameter and installed length | ________________________________ |
| Static water level and time | ________________________________ |
| Test flow, duration and pumping level at timed intervals | ________________________________ |
| Recovery readings and times after stopping | ________________________________ |
| Agreed charges, exclusions and variations | ________________________________ |
| Tester and customer sign-off | ________________________________ |
See the separate pump, cable and pipe installation costs
Quick answers
Does a deeper bore automatically need a higher-HP pump?
Select using the required flow and total head at the operating water level. Total drilled depth is one part of the installation record.
Does 18 L/min on the test guarantee that flow all year?
Use it as the measured flow under the recorded conditions. Ask the tester how season, run time and recovery affect the expected operating flow.