Illustration of one roof tank feeding two building wings

Automatic Water Level Controller Supplier in Vadodara

Mohit Vekaria

If you need an Automatic Water Level Controller Supplier in Vadodara, SubmersibleShop.com offers the VUKAR DEV-G4 for a compatible three-phase openwell or monoblock transfer pump. It can help when a low roof tank needs a refill during agreed building hours. If the roof tank already has water and only one wing has weak flow, ask the plumber to check that wing's pipe before buying a control.

Start with a building water flow check

A CEPT water audit of Vadodara's Karelibaug supply area maps nine groups with different supply periods. The team also checked valves, looked for pipe leaks and measured water reaching homes. A building committee can use the same simple idea on its own side of the meter. Record the tank level and the weak outlet at the same time. An old ward schedule gives context, but it cannot tell you the level in your tank today.

Ask two residents on the same floor to compare one cold-water outlet at about the same time, using the same size container. Note whether both outlets are fed by the same roof tank. The readings will not measure pressure directly. They can still help a plumber see whether to start with one tap or a shared pipe. If only one wing is slow while the tank is full, trace that wing's path first. If both wings lose water when the tank is low, check why the transfer pump has missed its refill.

Diagram comparing flow in two branches supplied by one full roof tank
In this example, the same full tank feeds both wings. A difference in outlet flow calls for a check along the weaker branch.

When a three-phase tank level controller fits

The DEV-G4 product page lists water-level control, two cable float switches, a clock timer and a cyclic timer. A float is a switch that moves with the water. On a typical two-tank transfer, one float reports when the ground tank has too little water and the other reports when the roof tank is full. Confirm the proposed functions with the electrician on the exact pump and starter. The controller cannot increase the pressure of the water leaving a full roof tank.

Worked example · One full tank, two outlets

Assume the roof tank is full. A 10-litre bucket fills in 40 seconds in the east wing but takes 100 seconds in the west wing. That is about 15 litres a minute versus 6. The readings flag a difference for the plumber to trace. If both wings lose flow on another day and the tank is low, investigate the fill system separately.

Observation First check
One wing slow and roof tank full Follow the branch pipe with a plumber
Both wings short and roof tank low Check the source tank and missed pump runs
Pump must run only in agreed hours Compare clock timing with both level stops

Send a clear photo of the motor label and existing starter before choosing the unit. Ask the electrician to identify the motor phase and how the new control will work with the old starter. A floor count or a pump size alone will not settle that choice. If a wing still has low flow after the roof tank fills, record the fault on a separate plumbing job.

Use a clock timer with floats for the building's own hours

The city inlet and the pump that moves stored water to the roof can operate at different times. Agree on when the building permits transfer. Use that period for the clock and the actual tank states for the stop tests. For example, the pump should stop if the source runs low before the allowed time is over. Ask who can change the hours and how the pump will respond when power comes back after the period has ended.

What to send for a Vadodara water controller quote

Send a small sketch showing both tanks and the wings they serve. Include the motor label, the weak outlets, the tank readings and the allowed hours. Ask for the controller and floats, extra cable, fitting and tests to be listed separately. In the handover, test a low source, a full roof tank and a normal fill with the person who looks after the pump. Leave the final settings and readings with the building log.

Use the three-phase level controller comparison to check whether clock timing is needed. Then send the tank sketch and motor label to VUKAR and ask for the matching model and installation scope.