Automatic Water Level Controller Supplier in Jalore

Mohit Vekaria

If you’re searching for an Automatic Water Level Controller Supplier in Jalore, SubmersibleShop.com offers VUKAR DEV-H2 for a compatible single-phase openwell or monoblock pump that moves water from a lower tank to an upper tank. First measure the litres your lower tank gains when water comes. If the total you catch falls below what you use between fills, start with the supply or storage checks below before spending on pump controls.

Jalore water supply window and your own inlet

Rajasthan's Public Health Engineering Department recorded a 90-minute supply duration for Jalore city in its 16 April 2024 monitoring sheet. The entry covered areas such as Shastri Nagar, the inner city and market, and Railway Station. The row also shows a broad time range of 6 am to 10 pm. Read the duration separately from that range. Treat both as a dated record and check your area's current timing. Jalore city monitoring sheet

A supply window is the time water reaches your inlet. Watch yours from the first steady flow until it stops. On the next supply day, compare your notes. If your start time moves but you still catch enough water, a level switch can run the transfer when the lower tank has water. A clock alone would follow the set time whether your tank has filled or stayed low. Rajasthan PHED water supply schedules

Illustrative volume bars showing 480 litres captured and 720 litres used between fills
In this example the inlet fill falls 240 L short of the amount used before the next fill.

Litres captured per fill compared with use

Use the tank gauge or the tank maker's marks. Record the level just before the supply starts and again after it stops. Pick a period when water is coming in and nobody draws from that tank, including the pump. Read from a safe place. If you cannot pause normal use or read the tank safely, ask the plumber to log the inlet meter or measure the incoming volume another way.

Worked example: a 240 L shortfall

Assume your lower tank has room and gains 480 L during the window. You use 720 L before the next fill. The difference is 240 L. If that repeats, focus first on why less water reaches the tank. If the same tank instead became full while the inlet was still running, check how much more water could actually be captured before choosing extra capacity.

What you see What to check next
Tank fills before the inlet stops Measure remaining inlet time and likely extra litres.
Tank has space when inlet stops Check actual inlet flow and supply timing.
Lower tank has water, upper tank stays low Check pump, float movement and controller fit.

Did the tank reach full before the inlet stopped? Extra space may help you catch more water in that case. If the tank still had room when supply stopped, check the inlet flow and timing first. Write down how many litres the building uses before the next fill. Include the time between fills. Comparing one fill with one day's use only makes sense when the tank gets a fill each day.

Single-phase tank transfer with two floats

DEV-H2 is designed for compatible single-phase openwell or monoblock pumps. A float is a switch that moves as the water rises or falls. Two float inputs let the electrician use lower-tank and upper-tank levels to control the transfer. Ask the installer to test that a low source tank stops the pump and that a full upper tank also stops it. DEV-H2 has a cyclic timer for repeated on and off periods. Check the model guide if you need a clock timer. DEV-H2 functions and wiring guidance

Controller quote for Jalore after the fill check

Send the supplier a photo of the motor plate, which shows the pump rating, plus a sketch of both tanks. Include each tank's capacity, the litres actually captured, the hours between fills, and the approximate float cable route. Ask the electrician to check that each float can move freely and that the existing starter, if present, fits the proposed setup. Put any change to the inlet, tank or controller on its own line in the quote.

Compare the VUKAR single-phase water level controller models. Then send your tank readings and pump photo so the supplier can check the right model for your measured fill and pump.