MOA-B Single Phase Monoblock Pump Starter with Water Level Controller
MOA-B Single Phase Monoblock Pump Starter with Water Level Controller
Couldn't load pickup availability
MOA-B Single Phase Monoblock Pump Starter with Water Level Controller is designed for 0.5–3 HP single phase monoblock (Tullu) pump variants. It combines pump operation controls with dry-run, overload and voltage protection.
Which application is this model for?
Choose this model when you need automatic overhead-tank filling from a single phase monoblock (Tullu) pump. MOA-B is the base automatic Water Level Controller model in this monoblock range.
What makes MOA-B different?
MOA-B is the base automatic tank-filling model. Its Water Level Controller uses the supplied cable float switch to start and stop the pump at configured tank levels. Cyclic Timer and motor protection are included; MCB and Clock Timer are not. Choose this model when level-based automation is needed without those two additions.
MOA-B HP variants and SKUs
| Motor rating | SKU |
|---|---|
| 0.5 HP | MOA-B0 |
| 0.75 HP | MOA-B1 |
| 1 HP | MOA-B2 |
| 1.5 HP | MOA-B3 |
| 2 HP | MOA-B4 |
| 3 HP | MOA-B5 |
Key functions
- Motor monitoring: dual digital display for voltage and current, plus motor-on and fault indications for troubleshooting.
- Motor records: fault counter and total run-time counter to support maintenance tracking.
- Water Level Controller: uses the supplied cable float switch to start at the configured low level and stop at the full level.
- Water Level Indicator: shows tank status from the supplied cable float switch. An indicator model does not automatically control tank filling unless a Water Level Controller is also included.
- Motor protection: overvoltage, undervoltage, overload and dry-run protection; check settings and the water source after a trip.
- Timer control: Cyclic Timer for repeating on/off cycles and Auto-Off Stop Timer for limiting a selected run duration.
- Restart control: Power-On Auto-Start delay and programmable dry-run retry to manage restart timing after supply or water-source recovery.
- Construction: powder-coated metal enclosure, FRLS internal wiring and a serviceable terminal layout.
Choose the correct HP variant
Options are available for 0.5, 0.75, 1, 1.5, 2 and 3 HP pumps. Match the selected variant to the pump nameplate. Before ordering, confirm the power supply, full-load current, cable size and starter settings with a qualified electrician.
Installation and operating notes
- Install the panel in a dry, ventilated location and provide proper earthing.
- Set voltage, current, dry-run and timer parameters for the connected pump; factory/default values may not suit every installation.
- Water-level functions depend on correct float-switch placement and wiring.
- After a protection trip, identify and correct the cause before restarting the pump.
Warranty, dispatch and support
- 1-year product warranty when purchased from this website.
- Orders are dispatched within 0–1 working day; expected delivery is 1–5 working days from the order date across India.
- Free shipping across India.
- Technical support by WhatsApp or call: +91 63588 96254.
Compare related starter panels
- Compare all single phase monoblock (Tullu) starter panel models
- Compare single phase openwell starter panel models
- View the VUKAR starter-panel comparison and price list
Product images and feature guides





















Frequently asked questions
Does this panel suit every 0.5–3 HP pump?
Select the matching HP variant and verify the pump nameplate, current, wiring and settings before installation.
Is professional installation required?
Yes. A qualified electrician should complete wiring, earthing, protection settings and commissioning.
Does this model automatically control tank filling?
Yes, when the supplied level sensor is installed and the Water Level Controller is wired and configured correctly.
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) કલેક્શન
અહીં Single Phase Borewell Level Control Panels (BOA)ના options compare કરો. પસંદ...
-
Three Phase Digital Auto Switch for Water Pumps કલેક્શન
અહીં Three Phase Digital Auto Switch for Water Pumpsના options compare કરો....
-
VUKARના બધા Products
એક listingમાં સંપૂર્ણ VUKAR catalogue જુઓ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) કલેક્શન
અહીં Three Phase Borewell DOL Panels with Timer (TPM)ના options compare કરો....
Blog posts
View all-
VUKAR Motor Starter Fault Codes: FOL, FDR, HIU,...
Mohit VekariaVUKAR FOL, FDR, HIU, LOU અને SPP: કયા products માટે લાગુ છે, common manual reset, DEV-Nની SET → RST exception, auto-clear conditions અને સુરક્ષિત મદદ.
VUKAR Motor Starter Fault Codes: FOL, FDR, HIU,...
Mohit VekariaVUKAR FOL, FDR, HIU, LOU અને SPP: કયા products માટે લાગુ છે, common manual reset, DEV-Nની SET → RST exception, auto-clear conditions અને સુરક્ષિત મદદ.
-
Submersible Pump Starter Panel: Functions અને S...
Mohit VekariaPanel પસંદ કરતાં કે automation ઉમેરતાં પહેલાં pump starter controls, protection limits અને model-selection checks સમજો.
Submersible Pump Starter Panel: Functions અને S...
Mohit VekariaPanel પસંદ કરતાં કે automation ઉમેરતાં પહેલાં pump starter controls, protection limits અને model-selection checks સમજો.
-
Three Phase Digital Motor Starter Panel કેવી રી...
Mohit VekariaMotor rating, documented protection, restart behaviour અને installation requirements જોઈને three-phase starter panel compare કરો.
Three Phase Digital Motor Starter Panel કેવી રી...
Mohit VekariaMotor rating, documented protection, restart behaviour અને installation requirements જોઈને three-phase starter panel compare કરો.
-
Motor Protection Device: Functions, Limits અને ...
Mohit Vekariaયોગ્ય starter panel જે faults detect કરવા માટે બનાવેલો અને set કરેલો હોય તે વખતે pump બંધ કરી શકે છે. સતત water supply, દરેક motor failureથી બચાવ કે maintenanceની જરૂર...
Motor Protection Device: Functions, Limits અને ...
Mohit Vekariaયોગ્ય starter panel જે faults detect કરવા માટે બનાવેલો અને set કરેલો હોય તે વખતે pump બંધ કરી શકે છે. સતત water supply, દરેક motor failureથી બચાવ કે maintenanceની જરૂર...
Blog posts
-
Indian Agriculture માટે 3 Phase Digital Auto Sw...
આ guideથી exact Three Phase Auto Switchના documented functions check કરો. Deviceને motor અને existing starter સાથે match કરો; protection supported functions, settings અને installation પર આધાર રાખે છે. 3...
Indian Agriculture માટે 3 Phase Digital Auto Sw...
આ guideથી exact Three Phase Auto Switchના documented functions check કરો. Deviceને motor અને existing starter સાથે match કરો; protection supported functions, settings અને installation પર આધાર રાખે છે. 3...
-
Borewell Panelમાં Motor Protection અને Water Le...
Water level control અને motor protection Water level control ધરાવતું borewell pump starter tank ભરવાનું કામ automatic કરી શકે છે, પરંતુ level control અને electrical protection અલગ functions છે. Panelને...
Borewell Panelમાં Motor Protection અને Water Le...
Water level control અને motor protection Water level control ધરાવતું borewell pump starter tank ભરવાનું કામ automatic કરી શકે છે, પરંતુ level control અને electrical protection અલગ functions છે. Panelને...