Single Phase Openwell Starter with MCB, 0.5–3 HP (OPM-H)
Single Phase Openwell Starter with MCB, 0.5–3 HP (OPM-H)
Couldn't load pickup availability
VUKAR OPM-H is a single phase openwell starter for 0.5–3 HP pumps. A built-in MCB adds short-circuit protection, while the Cyclic Timer and Auto Switch automate operation. Dry-run, overload and voltage protection help protect the pump motor.
High Brightness Dual Digital Display
The dual display shows the pump supply voltage and running current for quick operating checks.

Fault Display Indication
Fault indications help identify configured motor-protection trips during troubleshooting.

Motor Fault Counter
The counter records the number of motor faults so repeated trips can be reviewed.

Motor Total Run Time Counter
The run-time counter records cumulative motor operating hours for maintenance planning.

Motor On and Fault Indication
Separate indications show when the pump is running and when a protection fault is active.

Overvoltage and Undervoltage Protection
The controller disconnects the pump when supply voltage moves outside the configured limits.

Overload and Dry-Run Protection
Current-based protection stops the pump during overload or dry-run conditions, according to the configured settings.

Overload Safety Lockout
After the configured overload condition, lockout requires manual reset before operation resumes.

Auto-Off Stop Timer
The timer stops the motor after the selected running duration.

Power-On Auto-Start Timer
A configurable delay prevents immediate pump start when power returns.

Inbuilt Auto Switch
The Auto Switch restarts the pump when healthy power returns, subject to the configured protection settings.

Cyclic Timer Scheduler
The Cyclic Timer runs the pump in user-set ON and OFF cycles.

Programmable Auto-Restart Dry-Run Timer
After a dry-run trip, the controller waits for the selected interval before attempting restart.

Timer with Power-Failure Recovery
Timer settings resume after a power interruption according to the controller configuration.

Digital Product Registration
Product registration records the model and purchase details used for support and warranty service.

Serviceable Internal Wiring
Lug terminals and internal FRLS wiring support inspection and replacement by a qualified electrician.

440 V Motor Run Capacitor
The built-in 440 V run capacitor supports the selected single phase motor configuration.

MCB for Short-Circuit Protection
The built-in MCB disconnects the circuit during a short-circuit fault.

Spare Parts Availability
Compatible replacement parts and panel accessories can be requested from VUKAR support.

Protective Enclosure
The enclosure is designed to protect the internal control components during normal installed use.

Powder-Coated Metal Enclosure
The powder-coated metal enclosure provides a durable housing for the panel components.

Technical Support
For installation, fault codes, timer settings or warranty help, call or WhatsApp +91 63588 96254.

Support, warranty and delivery
- Technical support: call or WhatsApp +91 63588 96254.
- Sales, product selection, orders and delivery status: call or WhatsApp +91 95121 72271.
- Email: online@vukar.com.
- Warranty: manufacturing defects are covered by a 1-year part-replacement warranty. A paid 3-year extended warranty is optional.
- Shipping: free across India. Orders are dispatched in 0–1 working day and normally delivered in 1–5 working days, subject to courier or postal conditions.
- Replacement: eligible defective, damaged, wrong or not-as-described products must be reported within 7 calendar days of delivery. Policy conditions apply.
Frequently asked questions
Which pumps does OPM-H support?
Select the variant that matches a 0.5–3 HP single phase openwell pump.
Does OPM-H include an MCB?
Yes. OPM-H includes a built-in MCB for short-circuit protection.
Does it include water-level control?
No. OPM-H is an openwell starter panel without automatic water-level control. Choose an OPA model when tank-level automation is required.
How do I get installation or fault-code help?
Call or WhatsApp Technical Support at +91 63588 96254. Installation and live-terminal work must be performed by a qualified electrician with the supply isolated and verified dead.
Compare VUKAR models before you buy
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) કલેક્શન
આ collection Single Phase Borewell Level Control Panels (BOA) options માટે છે....
-
Three Phase Digital Auto Switch for Water Pumps કલેક્શન
આ collection Three Phase Digital Auto Switch for Water Pumps options માટે...
-
VUKARના બધા Products
એક listingમાં સંપૂર્ણ VUKAR catalogue જુઓ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) કલેક્શન
આ collection Three Phase Borewell DOL Panels with Timer (TPM) options માટે...
Blog posts
View all-
VUKAR Motor Starter Fault Codes: FOL, FDR, HIU,...
Mohit VekariaA model-safe guide to VUKAR FOL, FDR, HIU, LOU and SPP fault meanings, reset behaviour, automatic recovery and escalation.
VUKAR Motor Starter Fault Codes: FOL, FDR, HIU,...
Mohit VekariaA model-safe guide to VUKAR FOL, FDR, HIU, LOU and SPP fault meanings, reset behaviour, automatic recovery and escalation.
-
Submersible Pump Starter Panel: Motor સુરક્ષા
Mohit Vekariasubmersible pump starter panel તમને કેવી રીતે બચાવે છે Water flow હંમેશા safe રાખવાના exact steps જાણો. automatic water pump controller Setupના 5 Steps Water એટલે life. Pump બંધ થાય...
Submersible Pump Starter Panel: Motor સુરક્ષા
Mohit Vekariasubmersible pump starter panel તમને કેવી રીતે બચાવે છે Water flow હંમેશા safe રાખવાના exact steps જાણો. automatic water pump controller Setupના 5 Steps Water એટલે life. Pump બંધ થાય...
-
Best Three Phase Digital Motor Starter Panel કે...
Mohit VekariaBest Three Phase Digital Motor Starter Panel પસંદ કરો Burnt motorના ડરથી ઊંઘ ઊડી જાય છે? તમે એકલા નથી. Deep-well pump અચાનક બંધ થાય ત્યારે ઘણા મહેનતુ લોકો પર મોટો...
Best Three Phase Digital Motor Starter Panel કે...
Mohit VekariaBest Three Phase Digital Motor Starter Panel પસંદ કરો Burnt motorના ડરથી ઊંઘ ઊડી જાય છે? તમે એકલા નથી. Deep-well pump અચાનક બંધ થાય ત્યારે ઘણા મહેનતુ લોકો પર મોટો...
-
Production Shutdown રોકતું Motor Protection Device
Mohit VekariaMotor systemsની protection જોખમમાં મૂકીને થાકી ગયા? Modern motor protection deviceની આ guide systemને એક જગ્યાએ જોડવાનું સમજાવે છે. Motorને સંપૂર્ણ protection આપો અને uptime નક્કી કરો. Motorની Smart Protection:...
Production Shutdown રોકતું Motor Protection Device
Mohit VekariaMotor systemsની protection જોખમમાં મૂકીને થાકી ગયા? Modern motor protection deviceની આ guide systemને એક જગ્યાએ જોડવાનું સમજાવે છે. Motorને સંપૂર્ણ protection આપો અને uptime નક્કી કરો. Motorની Smart Protection:...
Blog posts
-
Indian Agriculture માટે 3 Phase Digital Auto Sw...
Agricultural Water Pumpની લાંબી life અને efficient operation માટે યોગ્ય Protection Features જરૂરી છે. ચાલો સમજીએ કે 3 Phase Digital Auto Switchના મુખ્ય features તમારા Water Pumpને સુરક્ષિત રાખવામાં અને...
Indian Agriculture માટે 3 Phase Digital Auto Sw...
Agricultural Water Pumpની લાંબી life અને efficient operation માટે યોગ્ય Protection Features જરૂરી છે. ચાલો સમજીએ કે 3 Phase Digital Auto Switchના મુખ્ય features તમારા Water Pumpને સુરક્ષિત રાખવામાં અને...
-
Borewell Panelમાં Motor Protection અને Water Le...
પરિચય: India માં પાણીની અછત એ એક સામાન્ય સમસ્યા છે, અને બોરવેલ એ ભૂગર્ભજળને ઍક્સેસ કરવાનો લોકપ્રિય ઉપાય છે. અવિરત પાણી પુરવઠાની ખાતરી કરવા માટે, borewell submersible pumps નો ઉપયોગ...
Borewell Panelમાં Motor Protection અને Water Le...
પરિચય: India માં પાણીની અછત એ એક સામાન્ય સમસ્યા છે, અને બોરવેલ એ ભૂગર્ભજળને ઍક્સેસ કરવાનો લોકપ્રિય ઉપાય છે. અવિરત પાણી પુરવઠાની ખાતરી કરવા માટે, borewell submersible pumps નો ઉપયોગ...