MOM-T Single Phase Monoblock (Tullu) Pump Starter with Clock Timer is designed for 0.5–3 HP single phase monoblock (Tullu) pump variants. It combines pump operation controls with dry-run, overload and voltage protection.
VUKAR MOM-T comes from pump control manufacturer Vukar Automation in Rajkot. For MOM-T bulk orders, send the quantity you need.
Which application is this model for?
Choose this model for motor protection and timed operation where automatic tank-level control is not required. MOM-T adds Clock Timer scheduling to the Cyclic Timer and motor-safety package.
What makes MOM-T different?
MOM-T is the scheduling model in the manual tank-control group. Its Clock Timer runs pump schedules at selected times, while the Cyclic Timer handles repeating on/off intervals. It does not include an MCB, Water Level Indicator or automatic Water Level Controller, so tank condition must be managed independently.
MOM-T HP variants and SKUs
| Motor rating | SKU |
|---|---|
| 0.5 HP | MOM-T0 |
| 0.75 HP | MOM-T1 |
| 1 HP | MOM-T2 |
| 1.5 HP | MOM-T3 |
| 2 HP | MOM-T4 |
| 3 HP | MOM-T5 |
Key functions
- Motor monitoring: dual digital display for voltage and current, plus motor-on and fault indications for troubleshooting.
- Motor records: fault counter and total run-time counter to support maintenance tracking.
- Motor protection: overvoltage, undervoltage, overload and dry-run protection; check settings and the water source after a trip.
- Timer control: Cyclic Timer for repeating on/off cycles and Auto-Off Stop Timer for limiting a selected run duration.
- Clock Timer: for time-of-day schedules; this is separate from the repeating Cyclic Timer.
- Auto Switch: manages pump operation according to the configured settings when healthy supply returns.
- Restart control: Power-On Auto-Start delay and programmable dry-run retry to manage restart timing after supply or water-source recovery.
- Construction: powder-coated metal enclosure, FRLS internal wiring and a serviceable terminal layout.
Choose the correct HP variant
Options are available for 0.5, 0.75, 1, 1.5, 2 and 3 HP pumps. Match the selected variant to the pump nameplate. Before ordering, confirm the power supply, full-load current, cable size and starter settings with a qualified electrician.
Installation and operating notes
- Install the panel in a dry, ventilated location and provide proper earthing.
- Set voltage, current, dry-run and timer parameters for the connected pump; factory/default values may not suit every installation.
- Use the timer settings for the required pump run and pause periods. This model uses timer-based operation rather than tank-level sensing.
- After a protection trip, identify and correct the cause before restarting the pump.
Warranty, dispatch and support
- 1-year product warranty when purchased from this website.
- Orders are dispatched within 0–1 working day; expected delivery is 1–5 working days from the order date across India.
- Free shipping across India.
- Technical support by WhatsApp or call: +91 63588 96254.
Compare related starter panels
- Compare all single phase monoblock (Tullu) starter panel models
- Compare single phase openwell starter panel models
- View the VUKAR starter-panel comparison and price list
Product images and feature guides
Display and everyday operation

Digital display
View supply voltage and motor current.

Fault display
View fault indications when troubleshooting the pump.

Motor fault counter
Keep track of motor faults.

Motor run-time counter
Track total motor operating time.

Motor ON indication
See when the pump is running.

Digital clock display
View the clock used for scheduled pump operation.
Protection and control features

Voltage protection
Overvoltage and undervoltage protection for the connected pump.

Dry-run protection
Dry-run protection for the connected pump.

Overload protection guide
Check protection settings after a trip.
Timing and automatic control

Auto-off stop timer
Stop the pump after the selected running duration.

Power-on start delay
Configure restart timing after supply recovery.

Cyclic Timer
Run the pump in repeated ON and OFF cycles.

Clock Timer
Schedule pump operation at selected times.

Dry-run restart delay
Use programmable dry-run retry to manage restart timing.

Timer settings guide
Set timer parameters for the connected pump.
Installation and ownership

Product-registration guide

Daily timing guide

Cyclic Timer guide

Clock scheduling guide

Serviceable internal wiring
FRLS wiring and terminals support inspection and servicing.

Internal components

Powder-coated metal enclosure
Metal cabinet with a powder-coated finish.
Frequently asked questions
Which pump should I select MOM-T for?
Choose the matching 0.5–3 HP variant for a single phase monoblock (Tullu) pump. Verify the pump nameplate, current, wiring and settings before installation.
Is professional installation required?
Yes. A qualified electrician should complete wiring, earthing, protection settings and commissioning.
Does this model automatically control tank filling?
No. This model does not include automatic Water Level Controller operation.
Product videos and selection guidance: MOM-T product videos.
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) કલેક્શન
અહીં Single Phase Borewell Level Control Panels (BOA)ના options compare કરો. પસંદ...
-
Three Phase Digital Auto Switch for Water Pumps કલેક્શન
અહીં Three Phase Digital Auto Switch for Water Pumpsના options compare કરો....
-
VUKARના બધા Products
એક listingમાં સંપૂર્ણ VUKAR catalogue જુઓ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) કલેક્શન
અહીં Three Phase Borewell DOL Panels with Timer (TPM)ના options compare કરો....
Blog posts
View all-
Star Delta Starter: કામ કરવાની રીત, Motorની જરૂ...
VUKAR AutomationStar-Delta Starting, છ Terminal અને Voltageની જરૂરિયાતો, Transitionના તબક્કા અને Starter પસંદ કરતાં પહેલાં જરૂરી તપાસો સમજો.
Star Delta Starter: કામ કરવાની રીત, Motorની જરૂ...
VUKAR AutomationStar-Delta Starting, છ Terminal અને Voltageની જરૂરિયાતો, Transitionના તબક્કા અને Starter પસંદ કરતાં પહેલાં જરૂરી તપાસો સમજો.
-
MCBનું પૂરું નામ: અર્થ, કાર્ય અને RCCBથી તફાવત
VUKAR AutomationMCB એટલે Miniature Circuit Breaker. Overload અને short-circuit protection, ઉપકરણનાં markings અને MCB, RCCB અથવા RCBOથી કેવી રીતે અલગ છે તે સમજો.
MCBનું પૂરું નામ: અર્થ, કાર્ય અને RCCBથી તફાવત
VUKAR AutomationMCB એટલે Miniature Circuit Breaker. Overload અને short-circuit protection, ઉપકરણનાં markings અને MCB, RCCB અથવા RCBOથી કેવી રીતે અલગ છે તે સમજો.
-
PM Surya Ghar Yojana: સબસિડી, અરજીનાં પગલાં અને...
VUKAR AutomationPM Surya Ghar ની Rooftop Solar સહાય સમજો, Installation ના ભાવપત્રકોની સરખામણી કરો અને સત્તાવાર અરજી પ્રક્રિયા માટે તૈયારી કરો.
PM Surya Ghar Yojana: સબસિડી, અરજીનાં પગલાં અને...
VUKAR AutomationPM Surya Ghar ની Rooftop Solar સહાય સમજો, Installation ના ભાવપત્રકોની સરખામણી કરો અને સત્તાવાર અરજી પ્રક્રિયા માટે તૈયારી કરો.
-
Submersible Pump ની મરામતનો ખર્ચ: કયા Parts અને...
Mohit Vekariaફક્ત Workshop ની રકમ નહીં, Submersible ની મરામતના સંપૂર્ણ કામની સરખામણી કરો. કામને મંજૂરી આપતાં પહેલાં Servicing, મુખ્ય Parts, બહાર કાઢવું અને ફરી Commission કરવાનું અલગ કરો.
Submersible Pump ની મરામતનો ખર્ચ: કયા Parts અને...
Mohit Vekariaફક્ત Workshop ની રકમ નહીં, Submersible ની મરામતના સંપૂર્ણ કામની સરખામણી કરો. કામને મંજૂરી આપતાં પહેલાં Servicing, મુખ્ય Parts, બહાર કાઢવું અને ફરી Commission કરવાનું અલગ કરો.
Blog posts
-
Indian Agriculture માટે 3 Phase Digital Auto Sw...
આ guideથી exact Three Phase Auto Switchના documented functions check કરો. Deviceને motor અને existing starter સાથે match કરો; protection supported functions, settings અને installation પર આધાર રાખે છે. Three-Phase...
Indian Agriculture માટે 3 Phase Digital Auto Sw...
આ guideથી exact Three Phase Auto Switchના documented functions check કરો. Deviceને motor અને existing starter સાથે match કરો; protection supported functions, settings અને installation પર આધાર રાખે છે. Three-Phase...
-
Borewell Starter Panels: Water Level Control અન...
Water level control અને motor protection Borewell Pump Starter માં Water Level Control હોય તો તે ટાંકી ભરવાનું કામ આપમેળે કરી શકે છે, પરંતુ Water Level Control અને વિદ્યુત સુરક્ષા...
Borewell Starter Panels: Water Level Control અન...
Water level control અને motor protection Borewell Pump Starter માં Water Level Control હોય તો તે ટાંકી ભરવાનું કામ આપમેળે કરી શકે છે, પરંતુ Water Level Control અને વિદ્યુત સુરક્ષા...