MOA-H Single Phase Monoblock Pump Starter with Controller & MCB
MOA-H Single Phase Monoblock Pump Starter with Controller & MCB
Couldn't load pickup availability
MOA-H Single Phase Monoblock Pump Starter with Controller & MCB is designed for 0.5–3 HP single phase monoblock (Tullu) pump variants. It combines pump operation controls with dry-run, overload and voltage protection.
VUKAR MOA-H comes from pump control manufacturer Vukar Automation in Rajkot. Use the MOA-H code when requesting product support.
Which application is this model for?
Choose this model when you need automatic overhead-tank filling from a single phase monoblock (Tullu) pump. MOA-H adds an MCB to the automatic Water Level Controller and Cyclic Timer package.
What makes MOA-H different?
MOA-H adds an inbuilt MCB to the automatic tank-filling package. It combines Water Level Controller, cable-float sensing, Cyclic Timer and motor protection. Clock Timer scheduling is not included. Choose it when the pump must follow tank levels and panel-circuit MCB protection is also required.
MOA-H HP variants and SKUs
| Motor rating | SKU |
|---|---|
| 0.5 HP | MOA-H0 |
| 0.75 HP | MOA-H1 |
| 1 HP | MOA-H2 |
| 1.5 HP | MOA-H3 |
| 2 HP | MOA-H4 |
| 3 HP | MOA-H5 |
Key functions
- Motor monitoring: dual digital display for voltage and current, plus motor-on and fault indications for troubleshooting.
- Motor records: fault counter and total run-time counter to support maintenance tracking.
- Water Level Controller: uses the supplied cable float switch to start at the configured low level and stop at the full level.
- Water Level Indicator: shows tank status from the supplied cable float switch. This model also includes a Water Level Controller for automatic tank filling.
- MCB: adds short-circuit protection for the panel circuit and wiring; have an electrician verify the correct rating.
- Motor protection: overvoltage, undervoltage, overload and dry-run protection; check settings and the water source after a trip.
- Timer control: Cyclic Timer for repeating on/off cycles and Auto-Off Stop Timer for limiting a selected run duration.
- Restart control: Power-On Auto-Start delay and programmable dry-run retry to manage restart timing after supply or water-source recovery.
- Construction: powder-coated metal enclosure, FRLS internal wiring and a serviceable terminal layout.
Choose the correct HP variant
Options are available for 0.5, 0.75, 1, 1.5, 2 and 3 HP pumps. Match the selected variant to the pump nameplate. Before ordering, confirm the power supply, full-load current, cable size and starter settings with a qualified electrician.
Installation and operating notes
- Install the panel in a dry, ventilated location and provide proper earthing.
- Set voltage, current, dry-run and timer parameters for the connected pump; factory/default values may not suit every installation.
- Water-level functions depend on correct float-switch placement and wiring.
- After a protection trip, identify and correct the cause before restarting the pump.
Warranty, dispatch and support
- 1-year product warranty when purchased from this website.
- Orders are dispatched within 0–1 working day; expected delivery is 1–5 working days from the order date across India.
- Free shipping across India.
- Technical support by WhatsApp or call: +91 63588 96254.
Compare related starter panels
- Compare all single phase monoblock (Tullu) starter panel models
- Compare single phase openwell starter panel models
- View the VUKAR starter-panel comparison and price list
Product images and feature guides
Display and everyday operation

Digital display
View supply voltage and motor current.

Fault display
View fault indications when troubleshooting the pump.

Motor fault counter
Keep track of motor faults.

Motor run-time counter
Track total motor operating time.

Motor ON indication
See when the pump is running.

Automatic tank-level control
Start and stop the pump according to tank level.
Protection and control features

Water Level Indicator
View the connected tank’s water-level status.

Voltage protection
Overvoltage and undervoltage protection for the connected pump.

Dry-run protection
Dry-run protection for the connected pump.

Overload protection guide
Check protection settings after a trip.
Timing and automatic control

Auto-off stop timer
Stop the pump after the selected running duration.

Power-on start delay
Configure restart timing after supply recovery.

Pump operation settings
Configure pump operation for the installation.

Cyclic Timer
Run the pump in repeated ON and OFF cycles.

Dry-run restart delay
Use programmable dry-run retry to manage restart timing.

Timer settings guide
Set timer parameters for the connected pump.
Installation and ownership

Product-registration guide

Serviceable internal wiring
FRLS wiring and terminals support inspection and servicing.

Inbuilt MCB
Short-circuit protection for the panel circuit.

Internal components

Powder-coated metal enclosure
Metal cabinet with a powder-coated finish.

Cable float switch included
Tank-level sensing through the supplied cable float switch.
Frequently asked questions
Which pump should I select MOA-H for?
Choose the matching 0.5–3 HP variant for a single phase monoblock (Tullu) pump. Verify the pump nameplate, current, wiring and settings before installation.
Is professional installation required?
Yes. A qualified electrician should complete wiring, earthing, protection settings and commissioning.
Does this model automatically control tank filling?
Yes, when the supplied level sensor is installed and the Water Level Controller is wired and configured correctly.
Product videos and selection guidance: MOA-H product videos.
VUKAR MOA-H Monoblock Starter Panel: Installation and Water-Level Settings
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) કલેક્શન
અહીં Single Phase Borewell Level Control Panels (BOA)ના options compare કરો. પસંદ...
-
Three Phase Digital Auto Switch for Water Pumps કલેક્શન
અહીં Three Phase Digital Auto Switch for Water Pumpsના options compare કરો....
-
VUKARના બધા Products
એક listingમાં સંપૂર્ણ VUKAR catalogue જુઓ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) કલેક્શન
અહીં Three Phase Borewell DOL Panels with Timer (TPM)ના options compare કરો....
Blog posts
View all-
TPO-H ટાંકી ભરાતી નથી? Float signal, મોટર અને પ...
Mohit VekariaTPO-Hની ટાંકી ન ભરાય તો પહેલાં બે level લખો.
TPO-H ટાંકી ભરાતી નથી? Float signal, મોટર અને પ...
Mohit VekariaTPO-Hની ટાંકી ન ભરાય તો પહેલાં બે level લખો.
-
TPM-W ટાંકીનું level display ખોટું? Float indic...
Mohit VekariaTPM-Wનું tank level display ખોટું લાગે તો ખરેખરનું level, float indicator અને pumpનો RUN કે rest લખો.
TPM-W ટાંકીનું level display ખોટું? Float indic...
Mohit VekariaTPM-Wનું tank level display ખોટું લાગે તો ખરેખરનું level, float indicator અને pumpનો RUN કે rest લખો.
-
TPM-V ટાંકીનું level display ખોટું? Float indic...
Mohit VekariaTPM-V પર tank level display ખોટું લાગે તો ખરેખરનું પાણીનું level અને indicator એક જ સમયે લખો.
TPM-V ટાંકીનું level display ખોટું? Float indic...
Mohit VekariaTPM-V પર tank level display ખોટું લાગે તો ખરેખરનું પાણીનું level અને indicator એક જ સમયે લખો.
-
TPM-T daily run time વહેલો અટકે છે? વીજળી ગયા પ...
Mohit VekariaTPM-Tમાં daily run time વહેલો અટકતો લાગે તો મોટર ખરેખર ચાલી એ મિનિટ અને વીજળી પાછી આવી એ સમય લખો.
TPM-T daily run time વહેલો અટકે છે? વીજળી ગયા પ...
Mohit VekariaTPM-Tમાં daily run time વહેલો અટકતો લાગે તો મોટર ખરેખર ચાલી એ મિનિટ અને વીજળી પાછી આવી એ સમય લખો.
Blog posts
View all-
WhatsApp દ્વારા VUKAR વોરંટી રજિસ્ટ્રેશન
ડિજિટલ મીટરમાં WRT સુધી જાઓ. 3 અંકનો કોડ અથવા ફોટો WhatsApp પર મોકલો. પાસવર્ડ નાખીને ડિવાઇસ ફરી ચાલુ કરો.
WhatsApp દ્વારા VUKAR વોરંટી રજિસ્ટ્રેશન
ડિજિટલ મીટરમાં WRT સુધી જાઓ. 3 અંકનો કોડ અથવા ફોટો WhatsApp પર મોકલો. પાસવર્ડ નાખીને ડિવાઇસ ફરી ચાલુ કરો.
-
Relay કેવી રીતે કામ કરે છે: Interactive Pump St...
Interactive relay walkthroughમાં pump start requestનો માર્ગ જુઓ અને ચાર સામાન્ય faults control sequence ક્યાં અટકાવે તે સમજો.
Relay કેવી રીતે કામ કરે છે: Interactive Pump St...
Interactive relay walkthroughમાં pump start requestનો માર્ગ જુઓ અને ચાર સામાન્ય faults control sequence ક્યાં અટકાવે તે સમજો.
-
Megger Test: હેતુ, પ્રક્રિયા અને Insulation Res...
Motor insulation resistance સમજો, ઘટતી megohm reading શું બતાવી શકે અને test reportમાં કઈ માહિતી માગવી તે જાણો.
Megger Test: હેતુ, પ્રક્રિયા અને Insulation Res...
Motor insulation resistance સમજો, ઘટતી megohm reading શું બતાવી શકે અને test reportમાં કઈ માહિતી માગવી તે જાણો.
-
RCBO Full Form: કામ કરવાની રીત અને RCCBથી તફાવત
RCBO શું સુરક્ષિત કરે છે, તેના markings કેવી રીતે વાંચવા અને RCCB તથા અલગ MCBs સાથે તેની તુલના જુઓ.
RCBO Full Form: કામ કરવાની રીત અને RCCBથી તફાવત
RCBO શું સુરક્ષિત કરે છે, તેના markings કેવી રીતે વાંચવા અને RCCB તથા અલગ MCBs સાથે તેની તુલના જુઓ.