Single Phase Digital Openwell / Borewell Starter Panel with Motor Safety, Motor Auto Off / Stop Timer, Water Level Indicator & MCB (BOM-W)
Single Phase Digital Openwell / Borewell Starter Panel with Motor Safety, Motor Auto Off / Stop Timer, Water Level Indicator & MCB (BOM-W)
Couldn't load pickup availability
BOM-W is a single phase borewell/openwell motor starter panel for 0.5–3 HP pumps. Its defining function is water level indicator, auto-off stop timer and inbuilt MCB. Select the exact HP variant only after matching the pump rating and operating current.
VUKAR BOM-W comes from pump control manufacturer Vukar Automation in Rajkot. Compare the listed BOM-W controls with your pump task.
Who should choose BOM-W?
Choose BOM-W when tank-level indication, timed stopping and an inbuilt MCB are all required in one starter panel.
Model-specific functions
- Water Level Indicator gives visible tank-status information from the connected float switch.
- Auto-Off Stop Timer stops the pump after the duration set on the panel.
- Inbuilt MCB provides short-circuit protection for the panel circuit; cable float switch is included.
Motor protection and monitoring
- Overvoltage and undervoltage protection disconnects the motor when supply voltage moves outside the configured limits.
- Overload and dry-run protection stops the pump when the configured current conditions indicate excess load or loss of water.
- Overload Safety Lockout, Power-On Auto-Start Timer and Programmable Dry-Run Auto-Restart Timer support controlled recovery after a fault or power interruption.
- Motor ON indication, fault display, fault counter and run-time counter provide operating information on the panel.
Product feature reference
Protection and control features

BOM-W: High brightness dual digital display on a single phase panel

BOM-W: Fault display indication showing motor error codes on the panel
BOM-W: Fault display indication showing motor error codes on the panel
BOM-W: Motor fault counter logging and displaying the number of trips
BOM-W: Motor fault counter logging and displaying the number of tripsTiming and automatic control

BOM-W: Motor run time counter logging cumulative pump operating hours
BOM-W: Motor run time counter logging cumulative pump operating hours
BOM-W: Motor on indication confirming the pump is currently running
BOM-W: Motor on indication confirming the pump is currently running
BOM-W: Water level indicator giving visual confirmation of tank status
BOM-W: Water level indicator giving visual confirmation of tank status
BOM-W: Overvoltage and undervoltage protection keeping the motor in safe limits
BOM-W: Overvoltage and undervoltage protection keeping the motor in safe limits
BOM-W: Dry run protection cutting power when the water source runs dry
BOM-W: Dry run protection cutting power when the water source runs dry
BOM-W: Auto off stop timer switching the motor off after a set duration
BOM-W: Auto off stop timer switching the motor off after a set durationInstallation and ownership

BOM-W: Panel internals with ISI marked copper wiring on heavy duty lugs
BOM-W: Panel internals with ISI marked copper wiring on heavy duty lugs
BOM-W: Built in 440 V motor run capacitor for stable starting
BOM-W: Built in 440 V motor run capacitor for stable starting
BOM-W: Inbuilt MCB giving short circuit protection in the panel
BOM-W: Inbuilt MCB giving short circuit protection in the panel
BOM-W: Powder coated metal enclosure protecting the panel internals
BOM-W: Powder coated metal enclosure protecting the panel internals
BOM-W: Cable float switch included for automatic tank level sensing
BOM-W: Cable float switch included for automatic tank level sensingInstallation and selection
- Use only with a compatible single phase borewell or openwell pump within the selected 0.5–3 HP variant range.
- Match the variant to the pump nameplate HP and current; protection settings must be configured for the actual motor.
- Installation, earthing, capacitor connections and sensor wiring should be completed by a qualified electrician.
- Tank sensor or float-switch positioning must be tested before automatic operation.
Warranty, delivery and support
- Warranty: 1 year when purchased from this website.
- Dispatch: 0–1 working day. Expected delivery: 1–5 working days from the order date across India.
- Shipping: free across India.
- Technical support: WhatsApp or call +91 63588 96254.
- To order by phone, send your name, address, contact number, PIN code and model to +91 95121 72271.
Frequently asked questions
Which pumps does BOM-W suit?
Select the matching 0.5–3 HP variant for a single phase borewell or openwell pump. Match the pump nameplate HP and current, and have a qualified electrician verify the wiring and capacitor requirements before installation.
Does BOM-W include automatic tank-level control?
No automatic tank-level control is claimed for this model. It includes tank-level indication through the supplied cable float switch.
Product videos and selection guidance: Water-level indicator videos.
VUKAR BOM-W Borewell Starter Panel: Installation and Auto-Off Timer Settings
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) કલેક્શન
અહીં Single Phase Borewell Level Control Panels (BOA)ના options compare કરો. પસંદ...
-
Three Phase Digital Auto Switch for Water Pumps કલેક્શન
અહીં Three Phase Digital Auto Switch for Water Pumpsના options compare કરો....
-
VUKARના બધા Products
એક listingમાં સંપૂર્ણ VUKAR catalogue જુઓ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) કલેક્શન
અહીં Three Phase Borewell DOL Panels with Timer (TPM)ના options compare કરો....
Blog posts
View all-
TPO-H ટાંકી ભરાતી નથી? Float signal, મોટર અને પ...
Mohit VekariaTPO-Hની ટાંકી ન ભરાય તો પહેલાં બે level લખો.
TPO-H ટાંકી ભરાતી નથી? Float signal, મોટર અને પ...
Mohit VekariaTPO-Hની ટાંકી ન ભરાય તો પહેલાં બે level લખો.
-
TPM-W ટાંકીનું level display ખોટું? Float indic...
Mohit VekariaTPM-Wનું tank level display ખોટું લાગે તો ખરેખરનું level, float indicator અને pumpનો RUN કે rest લખો.
TPM-W ટાંકીનું level display ખોટું? Float indic...
Mohit VekariaTPM-Wનું tank level display ખોટું લાગે તો ખરેખરનું level, float indicator અને pumpનો RUN કે rest લખો.
-
TPM-V ટાંકીનું level display ખોટું? Float indic...
Mohit VekariaTPM-V પર tank level display ખોટું લાગે તો ખરેખરનું પાણીનું level અને indicator એક જ સમયે લખો.
TPM-V ટાંકીનું level display ખોટું? Float indic...
Mohit VekariaTPM-V પર tank level display ખોટું લાગે તો ખરેખરનું પાણીનું level અને indicator એક જ સમયે લખો.
-
TPM-T daily run time વહેલો અટકે છે? વીજળી ગયા પ...
Mohit VekariaTPM-Tમાં daily run time વહેલો અટકતો લાગે તો મોટર ખરેખર ચાલી એ મિનિટ અને વીજળી પાછી આવી એ સમય લખો.
TPM-T daily run time વહેલો અટકે છે? વીજળી ગયા પ...
Mohit VekariaTPM-Tમાં daily run time વહેલો અટકતો લાગે તો મોટર ખરેખર ચાલી એ મિનિટ અને વીજળી પાછી આવી એ સમય લખો.
Blog posts
View all-
WhatsApp દ્વારા VUKAR વોરંટી રજિસ્ટ્રેશન
ડિજિટલ મીટરમાં WRT સુધી જાઓ. 3 અંકનો કોડ અથવા ફોટો WhatsApp પર મોકલો. પાસવર્ડ નાખીને ડિવાઇસ ફરી ચાલુ કરો.
WhatsApp દ્વારા VUKAR વોરંટી રજિસ્ટ્રેશન
ડિજિટલ મીટરમાં WRT સુધી જાઓ. 3 અંકનો કોડ અથવા ફોટો WhatsApp પર મોકલો. પાસવર્ડ નાખીને ડિવાઇસ ફરી ચાલુ કરો.
-
Relay કેવી રીતે કામ કરે છે: Interactive Pump St...
Interactive relay walkthroughમાં pump start requestનો માર્ગ જુઓ અને ચાર સામાન્ય faults control sequence ક્યાં અટકાવે તે સમજો.
Relay કેવી રીતે કામ કરે છે: Interactive Pump St...
Interactive relay walkthroughમાં pump start requestનો માર્ગ જુઓ અને ચાર સામાન્ય faults control sequence ક્યાં અટકાવે તે સમજો.
-
Megger Test: હેતુ, પ્રક્રિયા અને Insulation Res...
Motor insulation resistance સમજો, ઘટતી megohm reading શું બતાવી શકે અને test reportમાં કઈ માહિતી માગવી તે જાણો.
Megger Test: હેતુ, પ્રક્રિયા અને Insulation Res...
Motor insulation resistance સમજો, ઘટતી megohm reading શું બતાવી શકે અને test reportમાં કઈ માહિતી માગવી તે જાણો.
-
RCBO Full Form: કામ કરવાની રીત અને RCCBથી તફાવત
RCBO શું સુરક્ષિત કરે છે, તેના markings કેવી રીતે વાંચવા અને RCCB તથા અલગ MCBs સાથે તેની તુલના જુઓ.
RCBO Full Form: કામ કરવાની રીત અને RCCBથી તફાવત
RCBO શું સુરક્ષિત કરે છે, તેના markings કેવી રીતે વાંચવા અને RCCB તથા અલગ MCBs સાથે તેની તુલના જુઓ.