DEV-P2 3 Phase Auto Switch with Clock & Cyclic Timers
DEV-P2 3 Phase Auto Switch with Clock & Cyclic Timers
Couldn't load pickup availability
VUKAR DEV-P2 is a three phase digital auto switch with clock and cyclic timers for pump automation, monitoring and motor protection.
Who Should Choose This Model
Choose DEV-P2 when a three phase pump needs both time-of-day scheduling and repeated ON/OFF cycles.
Product and Installation Videos
Monitoring and Control
High-Brightness Dual Digital Display
Shows three phase voltage, current and other pump parameters during operation.

Fault Display Indication
Shows common motor-fault indications to support troubleshooting.

Motor Fault Counter
Records the number of detected motor faults so recurring conditions can be reviewed.

Motor Run-Time Counter
Records cumulative motor running time for maintenance planning.

Motor-On and Fault Indication
Provides visual indication of motor-running and fault status.

Digital Clock Display
Shows the clock and schedule information used for timed operation.

Overvoltage and Undervoltage Protection
Stops the pump when supply voltage moves outside the configured range.

Overload and Dry-Run Protection
Stops the motor during detected overload or dry-run conditions to reduce damage risk.

Phase-Loss and Phase-Sequence Protection
Checks phase availability and sequence before three phase pump operation.

Overload Safety Lockout
Keeps the controller stopped after an overload until a manual reset is completed.

Auto-Off Stop Timer
Stops the pump after the configured running duration.

Power-On Auto-Start Timer
Adds a configurable delay before pump start after power returns.

Protection and Automation
Built-In Auto Switch
Supports automatic pump start when the required supply conditions are available.

Cyclic Timer
Runs repeated ON/OFF cycles according to the configured schedule.

Clock Timer
Supports time-of-day pump scheduling through the clock timer.

Programmable Dry-Run Restart Timer
Stops the pump on dry run and retries after the configured recovery delay.

Timer Power-Failure Recovery
Restores the programmed timer cycle after a power interruption.

Digital Product Registration
Supports digital registration for product and service records.

Total Daily Run-Time Control
Controls the pump's total daily operating time according to the programmed setting.

Cyclic-Timer Operating Hours
Allows the cyclic timer's daily operating window to be configured.

Multi-Event Real-Time Scheduler
Supports up to 20 programmed start and stop events.

Hierarchical Timer
Supports individually configured cycles within a broader operating schedule.
Protective Enclosure
Uses a protective enclosure intended to support stable controller operation.

Technical Support
Technical support is available by WhatsApp and call at +91 63588 96254.

Selection and Installation
Use with a compatible three phase pump starter circuit. Verify motor rating, phase sequence, clock settings and wiring before commissioning.
Before Ordering
Verify motor rating, wiring and sensor configuration. Review the current Shipping Policy, Refund Policy and Contact page.
FAQ
Which application is DEV-P2 for?
Choose DEV-P2 when a three phase pump needs both time-of-day scheduling and repeated ON/OFF cycles.
Does it include a clock timer?
Yes. This model includes both clock and cyclic timers.
Compare Related Models
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) કલેક્શન
અહીં Single Phase Borewell Level Control Panels (BOA)ના options compare કરો. પસંદ...
-
Three Phase Digital Auto Switch for Water Pumps કલેક્શન
અહીં Three Phase Digital Auto Switch for Water Pumpsના options compare કરો....
-
VUKARના બધા Products
એક listingમાં સંપૂર્ણ VUKAR catalogue જુઓ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) કલેક્શન
અહીં Three Phase Borewell DOL Panels with Timer (TPM)ના options compare કરો....
Blog posts
View all-
VUKAR Motor Starter Fault Codes: FOL, FDR, HIU,...
Mohit VekariaVUKAR FOL, FDR, HIU, LOU અને SPP: કયા products માટે લાગુ છે, common manual reset, DEV-Nની SET → RST exception, auto-clear conditions અને સુરક્ષિત મદદ.
VUKAR Motor Starter Fault Codes: FOL, FDR, HIU,...
Mohit VekariaVUKAR FOL, FDR, HIU, LOU અને SPP: કયા products માટે લાગુ છે, common manual reset, DEV-Nની SET → RST exception, auto-clear conditions અને સુરક્ષિત મદદ.
-
Submersible Pump Starter Panel: Functions અને S...
Mohit VekariaPanel પસંદ કરતાં કે automation ઉમેરતાં પહેલાં pump starter controls, protection limits અને model-selection checks સમજો.
Submersible Pump Starter Panel: Functions અને S...
Mohit VekariaPanel પસંદ કરતાં કે automation ઉમેરતાં પહેલાં pump starter controls, protection limits અને model-selection checks સમજો.
-
Three Phase Digital Motor Starter Panel કેવી રી...
Mohit VekariaMotor rating, documented protection, restart behaviour અને installation requirements જોઈને three-phase starter panel compare કરો.
Three Phase Digital Motor Starter Panel કેવી રી...
Mohit VekariaMotor rating, documented protection, restart behaviour અને installation requirements જોઈને three-phase starter panel compare કરો.
-
Motor Protection Device: Functions, Limits અને ...
Mohit Vekariaયોગ્ય starter panel જે faults detect કરવા માટે બનાવેલો અને set કરેલો હોય તે વખતે pump બંધ કરી શકે છે. સતત water supply, દરેક motor failureથી બચાવ કે maintenanceની જરૂર...
Motor Protection Device: Functions, Limits અને ...
Mohit Vekariaયોગ્ય starter panel જે faults detect કરવા માટે બનાવેલો અને set કરેલો હોય તે વખતે pump બંધ કરી શકે છે. સતત water supply, દરેક motor failureથી બચાવ કે maintenanceની જરૂર...
Blog posts
-
Indian Agriculture માટે 3 Phase Digital Auto Sw...
આ guideથી exact Three Phase Auto Switchના documented functions check કરો. Deviceને motor અને existing starter સાથે match કરો; protection supported functions, settings અને installation પર આધાર રાખે છે. 3...
Indian Agriculture માટે 3 Phase Digital Auto Sw...
આ guideથી exact Three Phase Auto Switchના documented functions check કરો. Deviceને motor અને existing starter સાથે match કરો; protection supported functions, settings અને installation પર આધાર રાખે છે. 3...
-
Borewell Panelમાં Motor Protection અને Water Le...
Water level control અને motor protection Water level control ધરાવતું borewell pump starter tank ભરવાનું કામ automatic કરી શકે છે, પરંતુ level control અને electrical protection અલગ functions છે. Panelને...
Borewell Panelમાં Motor Protection અને Water Le...
Water level control અને motor protection Water level control ધરાવતું borewell pump starter tank ભરવાનું કામ automatic કરી શકે છે, પરંતુ level control અને electrical protection અલગ functions છે. Panelને...