DEV-H2 Single Phase Openwell Water Level Controller
DEV-H2 Single Phase Openwell Water Level Controller
Couldn't load pickup availability
VUKAR DEV-H2 is a single phase water level controller for openwell and monoblock pumps with double float-switch inputs, cyclic timer, monitoring and protection.
VUKAR DEV-H2 comes from pump control manufacturer Vukar Automation in Rajkot. Share your motor details when asking about DEV-H2.
Who Should Choose This Model
Choose DEV-H2 for a single phase openwell or monoblock pump that needs double float-switch level control and cyclic-timer operation.
Product and Installation Videos
Monitoring and motor protection

High-Brightness Dual Digital Display
Shows voltage, current and other pump parameters during operation.

Fault Display Indication
Shows common motor-fault indications to support troubleshooting.

Motor Fault Counter
Records the number of detected motor faults so recurring conditions can be reviewed.

Motor Run-Time Counter
Records cumulative motor running time for maintenance planning.

Motor-On and Fault Indication
Provides visual indication of motor-running and fault status.

Automatic Water Level Controller
Uses the connected float-switch input to start and stop the pump according to tank level.

Water Level Indicator
Shows the tank-level status used by the controller.

Overvoltage and Undervoltage Protection
Stops the pump when supply voltage moves outside the configured range.

Overload and Dry-Run Protection
Stops the motor during detected overload or dry-run conditions to reduce damage risk.

Overload Safety Lockout
Keeps the controller stopped after an overload until a manual reset is completed.
Timers and automatic operation

Auto-Off Stop Timer
Stops the pump after the configured running duration.

Power-On Auto-Start Timer
Adds a configurable delay before pump start after power returns.

Built-In Auto Switch
Supports automatic pump start when the required supply conditions are available.

Cyclic Timer
Runs repeated ON/OFF cycles according to the configured schedule.

Starting-Torque Timer
Controls the single phase motor-starting sequence through an adjustable timer.

Programmable Dry-Run Restart Timer
Stops the pump on dry run and retries after the configured recovery delay.

Timer Power-Failure Recovery
Restores the programmed timer cycle after a power interruption.
Installation and support

Digital Product Registration
Supports digital registration for product and service records.

Protective Enclosure

Technical Support
Technical support is available by WhatsApp and call at +91 63588 96254.

Double Cable Float Switch
Includes double cable float-switch inputs for openwell or monoblock tank-level control.
Selection and Installation
Use with a compatible single phase openwell or monoblock pump circuit. Have a qualified electrician connect both float-switch inputs and motor wiring according to the supplied wiring guide.
Before Ordering
Verify motor rating, wiring and sensor configuration. Review the current Shipping Policy, Refund Policy and Contact page.
FAQ
Which application is DEV-H2 for?
Choose DEV-H2 for a single phase openwell or monoblock pump that needs double float-switch level control and cyclic-timer operation.
Does it include a clock timer?
DEV-H2 uses cyclic timing for repeating ON/OFF operation and has no time-of-day clock timer. For clock scheduling in the same application, compare DEV-H4.
How should the float switch be connected?
Follow the supplied wiring guide and use a qualified electrician.
Compare Related Models
More VUKAR comparisons
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) કલેક્શન
અહીં Single Phase Borewell Level Control Panels (BOA)ના options compare કરો. પસંદ...
-
Three Phase Digital Auto Switch for Water Pumps કલેક્શન
અહીં Three Phase Digital Auto Switch for Water Pumpsના options compare કરો....
-
VUKARના બધા Products
એક listingમાં સંપૂર્ણ VUKAR catalogue જુઓ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) કલેક્શન
અહીં Three Phase Borewell DOL Panels with Timer (TPM)ના options compare કરો....
Blog posts
View all-
TPM-W ટાંકીનું level display ખોટું? Float indic...
Mohit VekariaTPM-Wનું tank level display ખોટું લાગે તો ખરેખરનું level, float indicator અને pumpનો RUN કે rest લખો.
TPM-W ટાંકીનું level display ખોટું? Float indic...
Mohit VekariaTPM-Wનું tank level display ખોટું લાગે તો ખરેખરનું level, float indicator અને pumpનો RUN કે rest લખો.
-
TPM-V ટાંકીનું level display ખોટું? Float indic...
Mohit VekariaTPM-V પર tank level display ખોટું લાગે તો ખરેખરનું પાણીનું level અને indicator એક જ સમયે લખો.
TPM-V ટાંકીનું level display ખોટું? Float indic...
Mohit VekariaTPM-V પર tank level display ખોટું લાગે તો ખરેખરનું પાણીનું level અને indicator એક જ સમયે લખો.
-
TPM-T daily run time વહેલો અટકે છે? વીજળી ગયા પ...
Mohit VekariaTPM-Tમાં daily run time વહેલો અટકતો લાગે તો મોટર ખરેખર ચાલી એ મિનિટ અને વીજળી પાછી આવી એ સમય લખો.
TPM-T daily run time વહેલો અટકે છે? વીજળી ગયા પ...
Mohit VekariaTPM-Tમાં daily run time વહેલો અટકતો લાગે તો મોટર ખરેખર ચાલી એ મિનિટ અને વીજળી પાછી આવી એ સમય લખો.
-
TPM-H three-phase pump વારંવાર trip? Cyclic sto...
Mohit VekariaTPM-Hનો three-phase pump વારંવાર trip થતો લાગે તો મોટર અટકી, overload indication દેખાયું કે built-in MCBની સ્થિતિ બદલાઈ એ નોંધો.
TPM-H three-phase pump વારંવાર trip? Cyclic sto...
Mohit VekariaTPM-Hનો three-phase pump વારંવાર trip થતો લાગે તો મોટર અટકી, overload indication દેખાયું કે built-in MCBની સ્થિતિ બદલાઈ એ નોંધો.
Blog posts
View all-
WhatsApp દ્વારા VUKAR વોરંટી રજિસ્ટ્રેશન
ડિજિટલ મીટરમાં WRT સુધી જાઓ. 3 અંકનો કોડ અથવા ફોટો WhatsApp પર મોકલો. પાસવર્ડ નાખીને ડિવાઇસ ફરી ચાલુ કરો.
WhatsApp દ્વારા VUKAR વોરંટી રજિસ્ટ્રેશન
ડિજિટલ મીટરમાં WRT સુધી જાઓ. 3 અંકનો કોડ અથવા ફોટો WhatsApp પર મોકલો. પાસવર્ડ નાખીને ડિવાઇસ ફરી ચાલુ કરો.
-
Relay કેવી રીતે કામ કરે છે: Interactive Pump St...
Interactive relay walkthroughમાં pump start requestનો માર્ગ જુઓ અને ચાર સામાન્ય faults control sequence ક્યાં અટકાવે તે સમજો.
Relay કેવી રીતે કામ કરે છે: Interactive Pump St...
Interactive relay walkthroughમાં pump start requestનો માર્ગ જુઓ અને ચાર સામાન્ય faults control sequence ક્યાં અટકાવે તે સમજો.
-
Megger Test: હેતુ, પ્રક્રિયા અને Insulation Res...
Motor insulation resistance સમજો, ઘટતી megohm reading શું બતાવી શકે અને test reportમાં કઈ માહિતી માગવી તે જાણો.
Megger Test: હેતુ, પ્રક્રિયા અને Insulation Res...
Motor insulation resistance સમજો, ઘટતી megohm reading શું બતાવી શકે અને test reportમાં કઈ માહિતી માગવી તે જાણો.
-
RCBO Full Form: કામ કરવાની રીત અને RCCBથી તફાવત
RCBO શું સુરક્ષિત કરે છે, તેના markings કેવી રીતે વાંચવા અને RCCB તથા અલગ MCBs સાથે તેની તુલના જુઓ.
RCBO Full Form: કામ કરવાની રીત અને RCCBથી તફાવત
RCBO શું સુરક્ષિત કરે છે, તેના markings કેવી રીતે વાંચવા અને RCCB તથા અલગ MCBs સાથે તેની તુલના જુઓ.