3 Phase DOL Starter with Water Level Indicator – TPM-V
3 Phase DOL Starter with Water Level Indicator – TPM-V
Couldn't load pickup availability
VUKAR TPM-V is a 3 phase DOL starter panel with an auto switch, cyclic timer and water level indicator for pumps up to 10 HP. Its digital display shows pump parameters while built-in protection covers dry-run, overload, voltage and phase faults.
Key Features
Fault Display Indication
Displays common motor fault indications to support faster troubleshooting.

Motor Fault Counter
Logs the number of motor faults so recurring issues can be identified.

Motor Total Run-Time Counter
Records cumulative motor running hours for maintenance planning.

Motor-On and Fault Indication
Provides clear visual confirmation of motor operation and fault status.

Water Level Indicator
Shows tank-water status for easier monitoring.

Overvoltage and Undervoltage Protection
Disconnects the pump when supply voltage moves outside the configured safe range.

Overload and Dry-Run Protection
Stops the motor during overload or dry-run conditions to reduce the risk of motor damage.

Single-Phase Preventer and Phase-Sequence Detection
Protects against phase loss and an incorrect phase sequence.

Overload Safety Lockout
Keeps the system stopped after an overload until a manual reset is completed.

Auto-Off Stop Timer
Stops the pump automatically after the configured running duration.

Power-On Auto-Start Timer
Adds a configurable delay before pump start when power returns.

Built-In Auto Switch
Starts the pump automatically when healthy three-phase power is available.

Cyclic Timer
Runs repeated ON/OFF cycles according to the configured schedule.

Programmable Auto-Restart Dry-Run Timer
Stops the pump on dry run and retries after the configured recovery delay.

Timer Power-Failure Recovery
Restores the programmed timer cycle after a power interruption.

Digital Product Registration and Auto/Manual Modes
Supports digital product registration and both automatic and manual operation modes.

Spare-Part Availability
Uses serviceable components intended for replacement through normal repair channels.

Powder-Coated Metal Enclosure
Protects internal components in a durable metal enclosure.

Cable Float Switch
Includes a cable float switch for tank-level input.

Technical Support
Technical support is available by WhatsApp and call at +91 63588 96254.
Suitable Pumps
TPM-V is configured for borewell, openwell and monoblock pumps up to 10 HP. Select the product variant that matches the motor HP.
Compare Before Buying
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) કલેક્શન
અહીં Single Phase Borewell Level Control Panels (BOA)ના options compare કરો. પસંદ...
-
Three Phase Digital Auto Switch for Water Pumps કલેક્શન
અહીં Three Phase Digital Auto Switch for Water Pumpsના options compare કરો....
-
VUKARના બધા Products
એક listingમાં સંપૂર્ણ VUKAR catalogue જુઓ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) કલેક્શન
અહીં Three Phase Borewell DOL Panels with Timer (TPM)ના options compare કરો....
Blog posts
View all-
VUKAR Motor Starter Fault Codes: FOL, FDR, HIU,...
Mohit VekariaVUKAR FOL, FDR, HIU, LOU અને SPP: કયા products માટે લાગુ છે, common manual reset, DEV-Nની SET → RST exception, auto-clear conditions અને સુરક્ષિત મદદ.
VUKAR Motor Starter Fault Codes: FOL, FDR, HIU,...
Mohit VekariaVUKAR FOL, FDR, HIU, LOU અને SPP: કયા products માટે લાગુ છે, common manual reset, DEV-Nની SET → RST exception, auto-clear conditions અને સુરક્ષિત મદદ.
-
Submersible Pump Starter Panel: Functions અને S...
Mohit VekariaPanel પસંદ કરતાં કે automation ઉમેરતાં પહેલાં pump starter controls, protection limits અને model-selection checks સમજો.
Submersible Pump Starter Panel: Functions અને S...
Mohit VekariaPanel પસંદ કરતાં કે automation ઉમેરતાં પહેલાં pump starter controls, protection limits અને model-selection checks સમજો.
-
Three Phase Digital Motor Starter Panel કેવી રી...
Mohit VekariaMotor rating, documented protection, restart behaviour અને installation requirements જોઈને three-phase starter panel compare કરો.
Three Phase Digital Motor Starter Panel કેવી રી...
Mohit VekariaMotor rating, documented protection, restart behaviour અને installation requirements જોઈને three-phase starter panel compare કરો.
-
Motor Protection Device: Functions, Limits અને ...
Mohit Vekariaયોગ્ય starter panel જે faults detect કરવા માટે બનાવેલો અને set કરેલો હોય તે વખતે pump બંધ કરી શકે છે. સતત water supply, દરેક motor failureથી બચાવ કે maintenanceની જરૂર...
Motor Protection Device: Functions, Limits અને ...
Mohit Vekariaયોગ્ય starter panel જે faults detect કરવા માટે બનાવેલો અને set કરેલો હોય તે વખતે pump બંધ કરી શકે છે. સતત water supply, દરેક motor failureથી બચાવ કે maintenanceની જરૂર...
Blog posts
-
Indian Agriculture માટે 3 Phase Digital Auto Sw...
આ guideથી exact Three Phase Auto Switchના documented functions check કરો. Deviceને motor અને existing starter સાથે match કરો; protection supported functions, settings અને installation પર આધાર રાખે છે. 3...
Indian Agriculture માટે 3 Phase Digital Auto Sw...
આ guideથી exact Three Phase Auto Switchના documented functions check કરો. Deviceને motor અને existing starter સાથે match કરો; protection supported functions, settings અને installation પર આધાર રાખે છે. 3...
-
Borewell Panelમાં Motor Protection અને Water Le...
Water level control અને motor protection Water level control ધરાવતું borewell pump starter tank ભરવાનું કામ automatic કરી શકે છે, પરંતુ level control અને electrical protection અલગ functions છે. Panelને...
Borewell Panelમાં Motor Protection અને Water Le...
Water level control અને motor protection Water level control ધરાવતું borewell pump starter tank ભરવાનું કામ automatic કરી શકે છે, પરંતુ level control અને electrical protection અલગ functions છે. Panelને...