MOA-B Single Phase Monoblock Pump Starter with Water Level Controller
MOA-B Single Phase Monoblock Pump Starter with Water Level Controller
Couldn't load pickup availability
MOA-B Single Phase Monoblock Pump Starter with Water Level Controller is designed for 0.5–3 HP single phase monoblock (Tullu) pump variants. It combines pump operation controls with dry-run, overload and voltage protection.
VUKAR MOA-B comes from pump control manufacturer Vukar Automation in Rajkot. Ask our sales team about MOA-B supply for your project.
Which application is this model for?
Choose this model when you need automatic overhead-tank filling from a single phase monoblock (Tullu) pump. MOA-B is the base automatic Water Level Controller model in this monoblock range.
What makes MOA-B different?
MOA-B is the base automatic tank-filling model. Its Water Level Controller uses the supplied cable float switch to start and stop the pump at configured tank levels. Cyclic Timer and motor protection are included; MCB and Clock Timer are not. Choose this model when level-based automation is needed without those two additions.
MOA-B HP variants and SKUs
| Motor rating | SKU |
|---|---|
| 0.5 HP | MOA-B0 |
| 0.75 HP | MOA-B1 |
| 1 HP | MOA-B2 |
| 1.5 HP | MOA-B3 |
| 2 HP | MOA-B4 |
| 3 HP | MOA-B5 |
Key functions
- Motor monitoring: dual digital display for voltage and current, plus motor-on and fault indications for troubleshooting.
- Motor records: fault counter and total run-time counter to support maintenance tracking.
- Water Level Controller: uses the supplied cable float switch to start at the configured low level and stop at the full level.
- Water Level Indicator: shows tank status from the supplied cable float switch. This model also includes a Water Level Controller for automatic tank filling.
- Motor protection: overvoltage, undervoltage, overload and dry-run protection; check settings and the water source after a trip.
- Timer control: Cyclic Timer for repeating on/off cycles and Auto-Off Stop Timer for limiting a selected run duration.
- Restart control: Power-On Auto-Start delay and programmable dry-run retry to manage restart timing after supply or water-source recovery.
- Construction: powder-coated metal enclosure, FRLS internal wiring and a serviceable terminal layout.
Choose the correct HP variant
Options are available for 0.5, 0.75, 1, 1.5, 2 and 3 HP pumps. Match the selected variant to the pump nameplate. Before ordering, confirm the power supply, full-load current, cable size and starter settings with a qualified electrician.
Installation and operating notes
- Install the panel in a dry, ventilated location and provide proper earthing.
- Set voltage, current, dry-run and timer parameters for the connected pump; factory/default values may not suit every installation.
- Water-level functions depend on correct float-switch placement and wiring.
- After a protection trip, identify and correct the cause before restarting the pump.
Warranty, dispatch and support
- 1-year product warranty when purchased from this website.
- Orders are dispatched within 0–1 working day; expected delivery is 1–5 working days from the order date across India.
- Free shipping across India.
- Technical support by WhatsApp or call: +91 63588 96254.
Compare related starter panels
- Compare all single phase monoblock (Tullu) starter panel models
- Compare single phase openwell starter panel models
- View the VUKAR starter-panel comparison and price list
Product images and feature guides
Display and everyday operation

Digital display
View supply voltage and motor current.

Fault display
View fault indications when troubleshooting the pump.

Motor fault counter
Keep track of motor faults.

Motor run-time counter
Track total motor operating time.

Motor ON indication
See when the pump is running.

Automatic tank-level control
Start and stop the pump according to tank level.
Protection and control features

Water Level Indicator
View the connected tank’s water-level status.

Voltage protection
Overvoltage and undervoltage protection for the connected pump.

Dry-run protection
Dry-run protection for the connected pump.

Overload protection guide
Check protection settings after a trip.
Timing and automatic control

Auto-off stop timer
Stop the pump after the selected running duration.

Power-on start delay
Configure restart timing after supply recovery.

Pump operation settings
Configure pump operation for the installation.

Cyclic Timer
Run the pump in repeated ON and OFF cycles.

Dry-run restart delay
Use programmable dry-run retry to manage restart timing.

Timer settings guide
Set timer parameters for the connected pump.
Installation and ownership

Product-registration guide

Serviceable internal wiring
FRLS wiring and terminals support inspection and servicing.

Internal components

Powder-coated metal enclosure
Metal cabinet with a powder-coated finish.

Cable float switch included
Tank-level sensing through the supplied cable float switch.
Frequently asked questions
Which pump should I select MOA-B for?
Choose the matching 0.5–3 HP variant for a single phase monoblock (Tullu) pump. Verify the pump nameplate, current, wiring and settings before installation.
Is professional installation required?
Yes. A qualified electrician should complete wiring, earthing, protection settings and commissioning.
Does this model automatically control tank filling?
Yes, when the supplied level sensor is installed and the Water Level Controller is wired and configured correctly.
Product videos and selection guidance: MOA-B product videos.
VUKAR MOA-B Monoblock Starter Panel: Installation and Water-Level Settings
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Single Phase Borewell Level Control Panels (BOA) options compare ಮಾಡಿ. ಆಯ್ಕೆ...
-
Three Phase Digital Auto Switch for Water Pumps ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Digital Auto Switch for Water Pumps options compare ಮಾಡಿ....
-
VUKARನ ಎಲ್ಲಾ Products
ಒಂದೇ listingನಲ್ಲಿ ಪೂರ್ಣ VUKAR catalogue ನೋಡಿ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Borewell DOL Panels with Timer (TPM) options compare ಮಾಡಿ....
Blog posts
View all-
TPM-W ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-W tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ level, float indicator ಮತ್ತು pumpನ RUN ಅಥವಾ rest ಬರೆಯಿರಿ.
TPM-W ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-W tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ level, float indicator ಮತ್ತು pumpನ RUN ಅಥವಾ rest ಬರೆಯಿರಿ.
-
TPM-V ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-V tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ ನೀರಿನ ಮಟ್ಟ ಮತ್ತು indicator ಅನ್ನು ಒಂದೇ ಹೊತ್ತಿನಲ್ಲಿ ಬರೆಯಿರಿ.
TPM-V ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-V tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ ನೀರಿನ ಮಟ್ಟ ಮತ್ತು indicator ಅನ್ನು ಒಂದೇ ಹೊತ್ತಿನಲ್ಲಿ ಬರೆಯಿರಿ.
-
TPM-T daily run time ಬೇಗ ನಿಲ್ಲುತ್ತದೆ? ವಿದ್ಯುತ್ ...
Mohit VekariaTPM-T daily run time ಬೇಗ ನಿಂತಂತೆ ಕಂಡರೆ ಮೋಟರ್ ನಿಜವಾಗಿ ಓಡಿದ ನಿಮಿಷಗಳು ಮತ್ತು ವಿದ್ಯುತ್ ಮರಳಿದ ಸಮಯ ದಾಖಲಿಸಿ.
TPM-T daily run time ಬೇಗ ನಿಲ್ಲುತ್ತದೆ? ವಿದ್ಯುತ್ ...
Mohit VekariaTPM-T daily run time ಬೇಗ ನಿಂತಂತೆ ಕಂಡರೆ ಮೋಟರ್ ನಿಜವಾಗಿ ಓಡಿದ ನಿಮಿಷಗಳು ಮತ್ತು ವಿದ್ಯುತ್ ಮರಳಿದ ಸಮಯ ದಾಖಲಿಸಿ.
-
TPM-H three-phase pump ಮತ್ತೆ ಮತ್ತೆ trip? Cyclic...
Mohit VekariaTPM-H three-phase pump ಮತ್ತೆ ಮತ್ತೆ trip ಆಗುತ್ತಿದೆ ಎಂದರೆ ಮೋಟರ್ ನಿಂತಿತೇ, overload ಸೂಚನೆ ಬಂತೇ ಅಥವಾ built-in MCB ಸ್ಥಾನ ಬದಲಾಯಿತೇ ಎಂದು ದಾಖಲಿಸಿ.
TPM-H three-phase pump ಮತ್ತೆ ಮತ್ತೆ trip? Cyclic...
Mohit VekariaTPM-H three-phase pump ಮತ್ತೆ ಮತ್ತೆ trip ಆಗುತ್ತಿದೆ ಎಂದರೆ ಮೋಟರ್ ನಿಂತಿತೇ, overload ಸೂಚನೆ ಬಂತೇ ಅಥವಾ built-in MCB ಸ್ಥಾನ ಬದಲಾಯಿತೇ ಎಂದು ದಾಖಲಿಸಿ.
Blog posts
View all-
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
-
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
-
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
-
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.