Single Phase Openwell Starter with MCB, 0.5–3 HP (OPM-H)
Single Phase Openwell Starter with MCB, 0.5–3 HP (OPM-H)
Couldn't load pickup availability
VUKAR OPM-H is a single phase openwell starter for 0.5–3 HP pumps. A built-in MCB adds short-circuit protection, while the Cyclic Timer and Auto Switch automate operation. Dry-run, overload and voltage protection help protect the pump motor.
VUKAR OPM-H comes from pump control manufacturer Vukar Automation in Rajkot. Share your motor details when asking about OPM-H.
Display and everyday operation

High Brightness Dual Digital Display
The dual display shows the pump supply voltage and running current for quick operating checks.

Fault Display Indication
Fault indications help identify configured motor-protection trips during troubleshooting.

Motor Fault Counter
The counter records the number of motor faults so repeated trips can be reviewed.

Motor Total Run Time Counter
The run-time counter records cumulative motor operating hours for maintenance planning.

Motor On and Fault Indication
Separate indications show when the pump is running and when a protection fault is active.
Protection and control features

Overvoltage and Undervoltage Protection
The controller disconnects the pump when supply voltage moves outside the configured limits.

Overload and Dry-Run Protection
Current-based protection stops the pump during overload or dry-run conditions, according to the configured settings.

Overload Safety Lockout
After the configured overload condition, lockout requires manual reset before operation resumes.
Timing and automatic control

Auto-Off Stop Timer
The timer stops the motor after the selected running duration.

Power-On Auto-Start Timer
A configurable delay prevents immediate pump start when power returns.

Inbuilt Auto Switch
The Auto Switch restarts the pump when healthy power returns, subject to the configured protection settings.

Cyclic Timer Scheduler
The Cyclic Timer runs the pump in user-set ON and OFF cycles.

Programmable Auto-Restart Dry-Run Timer
After a dry-run trip, the controller waits for the selected interval before attempting restart.

Timer with Power-Failure Recovery
Timer settings resume after a power interruption according to the controller configuration.
Installation and ownership

Digital Product Registration
Product registration records the model and purchase details used for support and warranty service.

Serviceable Internal Wiring
Lug terminals and internal FRLS wiring support inspection and replacement by a qualified electrician.

440 V Motor Run Capacitor
The built-in 440 V run capacitor supports the selected single phase motor configuration.

MCB for Short-Circuit Protection
The built-in MCB disconnects the circuit during a short-circuit fault.

Spare Parts Availability
Compatible replacement parts and panel accessories can be requested from VUKAR support.

Protective Enclosure
The enclosure is designed to protect the internal control components during normal installed use.

Powder-Coated Metal Enclosure
The powder-coated metal enclosure provides a durable housing for the panel components.

Technical Support
For installation, fault codes, timer settings or warranty help, call or WhatsApp +91 63588 96254.
Support, warranty and delivery
- Technical support: call or WhatsApp +91 63588 96254.
- Sales, product selection, orders and delivery status: call or WhatsApp +91 95121 72271.
- Email: online@vukar.com.
- Warranty: manufacturing defects are covered by a 1-year part-replacement warranty. A paid 3-year extended warranty is optional.
- Shipping: free across India. Orders are dispatched in 0–1 working day and normally delivered in 1–5 working days, subject to courier or postal conditions.
- Replacement: eligible defective, damaged, wrong or not-as-described products must be reported within 7 calendar days of delivery. Policy conditions apply.
Frequently asked questions
Which pumps does OPM-H support?
Select the variant that matches a 0.5–3 HP single phase openwell pump.
Does OPM-H include an MCB?
Yes. OPM-H includes a built-in MCB for short-circuit protection.
Does it include water-level control?
No. OPM-H is an openwell starter panel without automatic water-level control. Choose an OPA model when tank-level automation is required.
How do I get installation or fault-code help?
Call or WhatsApp Technical Support at +91 63588 96254. Installation and live-terminal work must be performed by a qualified electrician with the supply isolated and verified dead.
Compare VUKAR models before you buy
Product videos and selection guidance: OPM-C product videos.
VUKAR OPM-H Openwell Starter Panel: Installation and Cyclic Timer Settings
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Single Phase Borewell Level Control Panels (BOA) options compare ಮಾಡಿ. ಆಯ್ಕೆ...
-
Three Phase Digital Auto Switch for Water Pumps ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Digital Auto Switch for Water Pumps options compare ಮಾಡಿ....
-
VUKARನ ಎಲ್ಲಾ Products
ಒಂದೇ listingನಲ್ಲಿ ಪೂರ್ಣ VUKAR catalogue ನೋಡಿ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Borewell DOL Panels with Timer (TPM) options compare ಮಾಡಿ....
Blog posts
View all-
TPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲ? Float signal, ಮೋಟರ್...
Mohit VekariaTPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲವೆಂದರೆ ಮೊದಲು ಎರಡು level ದಾಖಲಿಸಿ.
TPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲ? Float signal, ಮೋಟರ್...
Mohit VekariaTPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲವೆಂದರೆ ಮೊದಲು ಎರಡು level ದಾಖಲಿಸಿ.
-
TPM-W ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-W tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ level, float indicator ಮತ್ತು pumpನ RUN ಅಥವಾ rest ಬರೆಯಿರಿ.
TPM-W ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-W tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ level, float indicator ಮತ್ತು pumpನ RUN ಅಥವಾ rest ಬರೆಯಿರಿ.
-
TPM-V ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-V tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ ನೀರಿನ ಮಟ್ಟ ಮತ್ತು indicator ಅನ್ನು ಒಂದೇ ಹೊತ್ತಿನಲ್ಲಿ ಬರೆಯಿರಿ.
TPM-V ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-V tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ ನೀರಿನ ಮಟ್ಟ ಮತ್ತು indicator ಅನ್ನು ಒಂದೇ ಹೊತ್ತಿನಲ್ಲಿ ಬರೆಯಿರಿ.
-
TPM-T daily run time ಬೇಗ ನಿಲ್ಲುತ್ತದೆ? ವಿದ್ಯುತ್ ...
Mohit VekariaTPM-T daily run time ಬೇಗ ನಿಂತಂತೆ ಕಂಡರೆ ಮೋಟರ್ ನಿಜವಾಗಿ ಓಡಿದ ನಿಮಿಷಗಳು ಮತ್ತು ವಿದ್ಯುತ್ ಮರಳಿದ ಸಮಯ ದಾಖಲಿಸಿ.
TPM-T daily run time ಬೇಗ ನಿಲ್ಲುತ್ತದೆ? ವಿದ್ಯುತ್ ...
Mohit VekariaTPM-T daily run time ಬೇಗ ನಿಂತಂತೆ ಕಂಡರೆ ಮೋಟರ್ ನಿಜವಾಗಿ ಓಡಿದ ನಿಮಿಷಗಳು ಮತ್ತು ವಿದ್ಯುತ್ ಮರಳಿದ ಸಮಯ ದಾಖಲಿಸಿ.
Blog posts
View all-
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
-
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
-
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
-
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.