Single Phase Openwell Starter with Clock & Cyclic Timers, 0.5–3 HP (OPM-T)
Single Phase Openwell Starter with Clock & Cyclic Timers, 0.5–3 HP (OPM-T)
Couldn't load pickup availability
VUKAR OPM-T is a single phase openwell starter for 0.5–3 HP pumps. It combines a Clock Timer, Cyclic Timer, Auto Switch, daily run-time control and motor protection for time-based pump operation. For automatic tank-level control, choose an OPA model.
VUKAR OPM-T comes from pump control manufacturer Vukar Automation in Rajkot. For OPM-T bulk orders, send the quantity you need.
Display and everyday operation

High-brightness dual display
Shows supply voltage, motor current, timer values and fault information for routine monitoring.

Fault display
Shows fault indications to help identify common pump and supply problems.

Motor fault counter
Records the number of motor trips so recurring faults can be reviewed.

Total run-time counter
Tracks cumulative motor operating hours for maintenance records.

Motor ON and fault indication
Shows whether the pump is running and provides a visible fault indication.

Digital clock display
Shows time, day and date for clock-based scheduling.
Protection and control features

Overvoltage and undervoltage protection
Stops the motor when supply voltage moves outside the user-set limits.

Overload and dry-run protection
Stops the pump when motor current indicates overload or dry-run conditions, using user-set thresholds.

Overload safety lockout
Requires a manual reset after the configured overload lockout condition.
Timing and automatic control

Auto-off stop timer
Stops the motor after the user-set run duration.

Power-on start delay
Delays motor restart after the electricity supply returns.

Inbuilt Auto Switch
Can start the pump automatically after healthy power returns, according to the configured settings.

Cyclic Timer
Runs repeated ON and OFF cycles using user-set durations.

Clock Timer
Starts and stops the pump at selected times and days.

Dry-run auto-restart timer
After a dry-run trip, waits for the user-set interval before attempting a restart.

Power-failure recovery
Retains the configured timer operation after a power interruption.
Advanced timer controls

Digital product registration
Lets the buyer register the product and keep the purchase record linked to support and warranty service.

Total daily run-time control
Limits total pump operating time to the user-set number of hours per day.

Cyclic Timer operating hours
Allows Cyclic Timer operation only within selected daily hours.

Multi-event real-time scheduler
Supports up to 20 start and stop programs for daily or weekly operation.
Hierarchical timer
Combines the broader time schedule with individually configured cycles.
Installation and ownership

Serviceable internal wiring
Uses lug-based FRLS internal wiring on terminals so internal parts can be serviced or replaced.

440 V motor run capacitor
Includes a 440 V run capacitor selected for the corresponding motor rating.

Spare-parts support
Replacement control-panel parts can be sourced for service; confirm the exact compatible part before purchase.

Protective enclosure
The metal enclosure shields the internal control components. Installation and earthing must be completed by a qualified electrician.

Powder-coated metal enclosure
The powder-coated metal cabinet protects the internal components during normal installed use.

Technical support
For installation, fault codes and warranty support, call or WhatsApp +91 63588 96254.
Who should choose OPM-T?
- 0.5–3 HP single phase openwell pumps
- Time-based operation using Clock and Cyclic Timers
- Automatic power-return start with motor protection
Warranty, shipping and support
A one-year parts replacement warranty applies to manufacturing defects. Requests for a defective, damaged, wrong or not-as-described product must be raised within seven days of delivery; change-of-mind returns are not offered. Shipping is free across India. Orders dispatch in 0–1 working day and delivery is normally expected 1–5 working days from the order date, subject to courier or postal service. An optional paid three-year extended warranty is available.
Frequently asked questions
Does OPM-T start or stop the pump by water level?
No. OPM-T provides time-based control. Choose an OPA model for automatic tank-level control.
Is an MCB included?
OPM-T provides clock and cyclic timing without an inbuilt MCB. Have a qualified electrician select the required external circuit protection using the supplied wiring guide.
How should it be installed?
Have a qualified electrician verify the motor rating, capacitor, protection settings, earthing and power wiring before operation.
Who handles order and delivery support?
Call or WhatsApp +91 95121 72271, or email online@vukar.com. For technical support, contact +91 63588 96254.
Compare VUKAR models before you buy
Product videos and selection guidance: OPM-T product videos.
VUKAR OPM-T Openwell Starter Panel: Installation and Clock Timer Settings
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Single Phase Borewell Level Control Panels (BOA) options compare ಮಾಡಿ. ಆಯ್ಕೆ...
-
Three Phase Digital Auto Switch for Water Pumps ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Digital Auto Switch for Water Pumps options compare ಮಾಡಿ....
-
VUKARನ ಎಲ್ಲಾ Products
ಒಂದೇ listingನಲ್ಲಿ ಪೂರ್ಣ VUKAR catalogue ನೋಡಿ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Borewell DOL Panels with Timer (TPM) options compare ಮಾಡಿ....
Blog posts
View all-
DOL Starter Coil Voltage: ಸರಿಯಾದ Replacement Co...
Mohit Vekariaಮೂರು ನಿಜವಾದ TeSys D part codes ಮೂಲಕ coil supply ಅರ್ಥಮಾಡಿಕೊಂಡು replacement ವಿವರ ಸಿದ್ಧಪಡಿಸಿ.
DOL Starter Coil Voltage: ಸರಿಯಾದ Replacement Co...
Mohit Vekariaಮೂರು ನಿಜವಾದ TeSys D part codes ಮೂಲಕ coil supply ಅರ್ಥಮಾಡಿಕೊಂಡು replacement ವಿವರ ಸಿದ್ಧಪಡಿಸಿ.
-
Forward/Reverse DOL Starter: Interlocks ಹೇಗೆ ಕೆ...
Mohit VekariaConveyor ಉದಾಹರಣೆಯ ಮೂಲಕ direction command, feedback ಮತ್ತು ನಿಜವಾದ ಚಲನೆಯನ್ನು ಬೇರ್ಪಡಿಸಿ.
Forward/Reverse DOL Starter: Interlocks ಹೇಗೆ ಕೆ...
Mohit VekariaConveyor ಉದಾಹರಣೆಯ ಮೂಲಕ direction command, feedback ಮತ್ತು ನಿಜವಾದ ಚಲನೆಯನ್ನು ಬೇರ್ಪಡಿಸಿ.
-
DOL Starter Overload Relay Range Chart: ಸರಿಯಾದ ...
Mohit Vekaria9.2 A ಉದಾಹರಣೆ, ಹೊಂದುವ relay ranges ಮತ್ತು ಸರಬರಾಜುದಾರರಿಗೆ ಬೇಕಾದ ವಿವರಗಳು.
DOL Starter Overload Relay Range Chart: ಸರಿಯಾದ ...
Mohit Vekaria9.2 A ಉದಾಹರಣೆ, ಹೊಂದುವ relay ranges ಮತ್ತು ಸರಬರಾಜುದಾರರಿಗೆ ಬೇಕಾದ ವಿವರಗಳು.
-
Timer ಇರುವ DOL Starter: Timed Stop, Run/Rest ಅಥ...
Mohit Vekariaಮೂರು pump ಉದಾಹರಣೆಗಳಿಂದ start ಮತ್ತು stop ಸ್ಥಿತಿಯನ್ನು ಬರೆದು ಸರಿಯಾದ timer ಆಯ್ಕೆ ಮಾಡಿ.
Timer ಇರುವ DOL Starter: Timed Stop, Run/Rest ಅಥ...
Mohit Vekariaಮೂರು pump ಉದಾಹರಣೆಗಳಿಂದ start ಮತ್ತು stop ಸ್ಥಿತಿಯನ್ನು ಬರೆದು ಸರಿಯಾದ timer ಆಯ್ಕೆ ಮಾಡಿ.
Blog posts
View all-
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
-
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
-
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
-
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.