BOA-H is a single phase borewell/openwell motor starter panel for 0.5–2 HP pumps. Its defining function is automatic water level control, cyclic timer and inbuilt MCB. Select the exact HP variant only after matching the pump rating and operating current.
VUKAR BOA-H comes from pump control manufacturer Vukar Automation in Rajkot. For BOA-H bulk orders, send the quantity you need.
Who should choose BOA-H?
Choose BOA-H when tank-level automation and repeat-cycle control are required together with an inbuilt MCB.
Model-specific functions
- Automatic Water Level Controller starts and stops the pump from tank-level demand.
- Cyclic Timer supports repeated ON/OFF operation.
- Inbuilt MCB provides short-circuit protection for the panel circuit; cable float switch is included.
Motor protection and monitoring
- Overvoltage and undervoltage protection disconnects the motor when supply voltage moves outside the configured limits.
- Overload and dry-run protection stops the pump when the configured current conditions indicate excess load or loss of water.
- Overload Safety Lockout, Power-On Auto-Start Timer and Programmable Dry-Run Auto-Restart Timer support controlled recovery after a fault or power interruption.
- Motor ON indication, fault display, fault counter and run-time counter provide operating information on the panel.
Product feature reference
Protection and control features

BOA-H: High brightness dual digital display on a single phase panel
BOA-H: High brightness dual digital display on a single phase panel
BOA-H: Fault display indication showing motor error codes on the panel
BOA-H: Fault display indication showing motor error codes on the panel
BOA-H: Motor fault counter logging and displaying the number of trips
BOA-H: Motor fault counter logging and displaying the number of tripsTiming and automatic control

BOA-H: Motor run time counter logging cumulative pump operating hours
BOA-H: Motor run time counter logging cumulative pump operating hours
BOA-H: Motor on indication confirming the pump is currently running
BOA-H: Motor on indication confirming the pump is currently running
BOA-H: Water level controller starting and stopping the motor by tank level
BOA-H: Water level controller starting and stopping the motor by tank level
BOA-H: Water level indicator giving visual confirmation of tank status
BOA-H: Water level indicator giving visual confirmation of tank status
BOA-H: Overvoltage and undervoltage protection keeping the motor in safe limits
BOA-H: Overvoltage and undervoltage protection keeping the motor in safe limits
BOA-H: Dry run protection cutting power when the water source runs dry
BOA-H: Dry run protection cutting power when the water source runs dry
BOA-H: Overload safety lockout halting operation after repeated overload trips
BOA-H: Overload safety lockout halting operation after repeated overload trips
BOA-H: Auto off stop timer switching the motor off after a set duration
BOA-H: Auto off stop timer switching the motor off after a set duration
BOA-H: Power on auto start timer delaying restart after supply returns
BOA-H: Power on auto start timer delaying restart after supply returns
BOA-H: Inbuilt auto switch managing automatic pump start and stop
BOA-H: Inbuilt auto switch managing automatic pump start and stop
BOA-H: Cyclic timer scheduler running the pump in timed on off cycles
BOA-H: Cyclic timer scheduler running the pump in timed on off cycles
BOA-H: Auto adjustable starting torque timer easing motor starts
BOA-H: Auto adjustable starting torque timer easing motor starts
BOA-H: Timer with power failure recovery keeping schedules after outages
BOA-H: Timer with power failure recovery keeping schedules after outagesInstallation and ownership

BOA-H: Panel internals with ISI marked copper wiring on heavy duty lugs
BOA-H: Panel internals with ISI marked copper wiring on heavy duty lugs
BOA-H: Built in 440 V motor run capacitor for stable starting
BOA-H: Built in 440 V motor run capacitor for stable starting
BOA-H: Inbuilt MCB giving short circuit protection in the panel
BOA-H: Inbuilt MCB giving short circuit protection in the panel
BOA-H: Powder coated metal enclosure protecting the panel internals
BOA-H: Powder coated metal enclosure protecting the panel internals
BOA-H: Cable float switch included for automatic tank level sensing
BOA-H: Cable float switch included for automatic tank level sensingInstallation and selection
- Use only with a compatible single phase borewell or openwell pump within the selected 0.5–2 HP variant range.
- Match the variant to the pump nameplate HP and current; protection settings must be configured for the actual motor.
- Installation, earthing, capacitor connections and sensor wiring should be completed by a qualified electrician.
- Tank sensor or float-switch positioning must be tested before automatic operation.
Warranty, delivery and support
- Warranty: 1 year when purchased from this website.
- Dispatch: 0–1 working day. Expected delivery: 1–5 working days from the order date across India.
- Shipping: free across India; no hidden or extra charge stated for the order.
- Technical support: WhatsApp or call +91 63588 96254.
- To order by phone, send your name, address, contact number, PIN code and model to +91 95121 72271.
Frequently asked questions
Does the panel work with every single phase pump?
No. Choose the correct HP/current variant for the pump nameplate and verify wiring and capacitor requirements before installation.
Does BOA-H include automatic tank-level control?
Yes. This BOA model includes automatic water level control and a cable float switch.
Product videos and selection guidance: BOA-H product videos.
VUKAR BOA-H Borewell Starter Panel: Installation and Water-Level Settings
Share
Customers are saying

Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Single Phase Borewell Level Control Panels (BOA) options compare ಮಾಡಿ. ಆಯ್ಕೆ...
-
Three Phase Digital Auto Switch for Water Pumps ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Digital Auto Switch for Water Pumps options compare ಮಾಡಿ....
-
VUKARನ ಎಲ್ಲಾ Products
ಒಂದೇ listingನಲ್ಲಿ ಪೂರ್ಣ VUKAR catalogue ನೋಡಿ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Borewell DOL Panels with Timer (TPM) options compare ಮಾಡಿ....
Blog posts
View all-
TPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲ? Float signal, ಮೋಟರ್...
Mohit VekariaTPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲವೆಂದರೆ ಮೊದಲು ಎರಡು level ದಾಖಲಿಸಿ.
TPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲ? Float signal, ಮೋಟರ್...
Mohit VekariaTPO-H ಟ್ಯಾಂಕ್ ತುಂಬುತ್ತಿಲ್ಲವೆಂದರೆ ಮೊದಲು ಎರಡು level ದಾಖಲಿಸಿ.
-
TPM-W ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-W tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ level, float indicator ಮತ್ತು pumpನ RUN ಅಥವಾ rest ಬರೆಯಿರಿ.
TPM-W ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-W tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ level, float indicator ಮತ್ತು pumpನ RUN ಅಥವಾ rest ಬರೆಯಿರಿ.
-
TPM-V ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-V tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ ನೀರಿನ ಮಟ್ಟ ಮತ್ತು indicator ಅನ್ನು ಒಂದೇ ಹೊತ್ತಿನಲ್ಲಿ ಬರೆಯಿರಿ.
TPM-V ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-V tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ ನೀರಿನ ಮಟ್ಟ ಮತ್ತು indicator ಅನ್ನು ಒಂದೇ ಹೊತ್ತಿನಲ್ಲಿ ಬರೆಯಿರಿ.
-
TPM-T daily run time ಬೇಗ ನಿಲ್ಲುತ್ತದೆ? ವಿದ್ಯುತ್ ...
Mohit VekariaTPM-T daily run time ಬೇಗ ನಿಂತಂತೆ ಕಂಡರೆ ಮೋಟರ್ ನಿಜವಾಗಿ ಓಡಿದ ನಿಮಿಷಗಳು ಮತ್ತು ವಿದ್ಯುತ್ ಮರಳಿದ ಸಮಯ ದಾಖಲಿಸಿ.
TPM-T daily run time ಬೇಗ ನಿಲ್ಲುತ್ತದೆ? ವಿದ್ಯುತ್ ...
Mohit VekariaTPM-T daily run time ಬೇಗ ನಿಂತಂತೆ ಕಂಡರೆ ಮೋಟರ್ ನಿಜವಾಗಿ ಓಡಿದ ನಿಮಿಷಗಳು ಮತ್ತು ವಿದ್ಯುತ್ ಮರಳಿದ ಸಮಯ ದಾಖಲಿಸಿ.
Blog posts
View all-
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
-
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
-
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
-
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.