Skip to product information
1 of 15

Single Phase Openwell / Borewell Automatic Starter Panel with Water Level Controller, Motor Safety, Cyclic Timer & Clock Timer (BOA-T)

Single Phase Openwell / Borewell Automatic Starter Panel with Water Level Controller, Motor Safety, Cyclic Timer & Clock Timer (BOA-T)

Regular price Rs. 5,599.00
Regular price Rs. 8,370.00 Sale price Rs. 5,599.00
Sale Sold out
Taxes included. Free shipping across India. View shipping policy.
Quantity
HP Rating
Feature

BOA-T is a single phase borewell/openwell motor starter panel for 0.5–2 HP pumps. Its defining function is automatic water level control, clock timer and cyclic timer. Select the exact HP variant only after matching the pump rating and operating current.

Who should choose BOA-T?

Choose BOA-T when tank-level automation must operate only during planned hours or alongside real-time pump schedules.

Model-specific functions

  • Automatic Water Level Controller starts and stops the pump from tank-level demand.
  • Clock Timer and Cyclic Timer provide time-based and repeat-cycle control.
  • Cable float switch is included; digital clock display supports scheduling.

Motor protection and monitoring

  • Overvoltage and undervoltage protection disconnects the motor when supply voltage moves outside the configured limits.
  • Overload and dry-run protection stops the pump when the configured current conditions indicate excess load or loss of water.
  • Overload Safety Lockout, Power-On Auto-Start Timer and Programmable Dry-Run Auto-Restart Timer support controlled recovery after a fault or power interruption.
  • Motor ON indication, fault display, fault counter and run-time counter provide operating information on the panel.

Product feature reference

High brightness dual digital display on a single phase panel
BOA-T: High brightness dual digital display on a single phase panel
Fault display indication showing motor error codes on the panel
BOA-T: Fault display indication showing motor error codes on the panel
Motor fault counter logging and displaying the number of trips
BOA-T: Motor fault counter logging and displaying the number of trips
Motor run time counter logging cumulative pump operating hours
BOA-T: Motor run time counter logging cumulative pump operating hours
Motor on indication confirming the pump is currently running
BOA-T: Motor on indication confirming the pump is currently running
Water level controller starting and stopping the motor by tank level
BOA-T: Water level controller starting and stopping the motor by tank level
Water level indicator giving visual confirmation of tank status
BOA-T: Water level indicator giving visual confirmation of tank status
Digital clock display showing time, day and date for scheduling
BOA-T: Digital clock display showing time, day and date for scheduling
Overvoltage and undervoltage protection keeping the motor in safe limits
BOA-T: Overvoltage and undervoltage protection keeping the motor in safe limits
Overload protection tripping the motor on excess current
BOA-T: Overload protection tripping the motor on excess current
Overload safety lockout halting operation after repeated overload trips
BOA-T: Overload safety lockout halting operation after repeated overload trips
Auto off stop timer switching the motor off after a set duration
BOA-T: Auto off stop timer switching the motor off after a set duration
Power on auto start timer delaying restart after supply returns
BOA-T: Power on auto start timer delaying restart after supply returns
Inbuilt auto switch managing automatic pump start and stop
BOA-T: Inbuilt auto switch managing automatic pump start and stop
Cyclic timer scheduler running the pump in timed on off cycles
BOA-T: Cyclic timer scheduler running the pump in timed on off cycles
Clock timer scheduler switching the pump at set times daily
BOA-T: Clock timer scheduler switching the pump at set times daily
Auto adjustable starting torque timer easing motor starts
BOA-T: Auto adjustable starting torque timer easing motor starts
Programmable auto restart timer retrying the pump after dry run cutoff
BOA-T: Programmable auto restart timer retrying the pump after dry run cutoff
Timer with power failure recovery keeping schedules after outages
BOA-T: Timer with power failure recovery keeping schedules after outages
Total daily runtime control capping pump hours per day
BOA-T: Total daily runtime control capping pump hours per day
User settable operating hours for the water level controller
BOA-T: User settable operating hours for the water level controller
User settable operating hours combined with the cyclic timer
BOA-T: User settable operating hours combined with the cyclic timer
Multi event real time scheduler supporting up to 20 programs
BOA-T: Multi event real time scheduler supporting up to 20 programs
Panel internals with ISI marked copper wiring on heavy duty lugs
BOA-T: Panel internals with ISI marked copper wiring on heavy duty lugs
Built in 440 V motor run capacitor for stable starting
BOA-T: Built in 440 V motor run capacitor for stable starting
Powder coated metal enclosure protecting the panel internals
BOA-T: Powder coated metal enclosure protecting the panel internals
Cable float switch included for automatic tank level sensing
BOA-T: Cable float switch included for automatic tank level sensing

Installation and selection

  • Use only with a compatible single phase borewell or openwell pump within the selected 0.5–2 HP variant range.
  • Match the variant to the pump nameplate HP and current; protection settings must be configured for the actual motor.
  • Installation, earthing, capacitor connections and sensor wiring should be completed by a qualified electrician.
  • Tank sensor or float-switch positioning must be tested before automatic operation.

Warranty, delivery and support

  • Warranty: 1 year when purchased from this website.
  • Dispatch: 0–1 working day. Expected delivery: 1–5 working days from the order date across India.
  • Shipping: free across India; no hidden or extra charge stated for the order.
  • Technical support: WhatsApp or call +91 63588 96254.
  • To order by phone, send your name, address, contact number, PIN code and model to +91 95121 72271.

Frequently asked questions

Does the panel work with every single phase pump?

No. Choose the correct HP/current variant for the pump nameplate and verify wiring and capacitor requirements before installation.

Does BOA-T include automatic tank-level control?

Yes. This BOA model includes automatic water level control and a cable float switch.

View full details
1 of 4
  • 3 Phase Digital Auto Switch - VUKAR

    Features of 3 Phase Digital Auto Switch for Ind...

    When it comes to ensuring the longevity and efficiency of your agricultural water pump, having the right protection features in place is crucial. Let's explore the key features that can...

    Features of 3 Phase Digital Auto Switch for Ind...

    When it comes to ensuring the longevity and efficiency of your agricultural water pump, having the right protection features in place is crucial. Let's explore the key features that can...

  • The Importance of Motor Protection in Borewell Submersible Starter Panels with Water Level Controller - VUKAR

    The Importance of Motor Protection in Borewell ...

    Introduction: Water scarcity is a common problem in India, and borewells are a popular solution to access groundwater. To ensure an uninterrupted water supply, borewell submersible pumps are used. However,...

    The Importance of Motor Protection in Borewell ...

    Introduction: Water scarcity is a common problem in India, and borewells are a popular solution to access groundwater. To ensure an uninterrupted water supply, borewell submersible pumps are used. However,...