Heavy-Duty Single Phase Digital Auto Switch, 5–200A – DEV-K4
Heavy-Duty Single Phase Digital Auto Switch, 5–200A – DEV-K4
Couldn't load pickup availability
VUKAR DEV-K4 is a heavy-duty single phase digital auto switch for 5–200A pump-motor applications. It combines clock and cyclic timers with dry-run, overload and voltage protection.
VUKAR DEV-K4 comes from pump control manufacturer Vukar Automation in Rajkot. For DEV-K4 bulk orders, send the quantity you need.
Product and Installation Videos
Monitoring and motor protection

High-Brightness Dual Digital Display
Shows voltage, current and other pump parameters for quick checks during operation.

Fault Display Indication
Displays common motor fault indications to support faster troubleshooting.

Motor Fault Counter
Logs the number of motor faults so recurring issues can be identified.

Motor Total Run-Time Counter
Records cumulative motor running hours to support maintenance planning.

Motor-On and Fault Indication
Provides clear visual indication of motor-running and fault status.

Digital Clock Display
Shows clock and schedule information used for timed pump operation.

Overvoltage and Undervoltage Protection
Stops the pump when supply voltage moves outside the configured safe range.

Overload and Dry-Run Protection
Stops the motor during overload or dry-run conditions to reduce damage risk.

Overload Safety Lockout
Keeps the system stopped after an overload until a manual reset is completed.
Timers and automatic operation

Auto-Off Stop Timer
Stops the pump automatically after the configured running duration.

Power-On Auto-Start Timer
Adds a configurable delay before pump start when power returns.

Built-In Auto Switch
Supports automatic pump start when healthy single-phase power is available.

Cyclic Timer
Runs repeated ON/OFF cycles according to the configured schedule.

Clock Timer
Supports time-of-day pump scheduling through the clock timer.

Auto-Adjustable Starting-Torque Timer
Controls the motor-starting sequence through an adjustable starting-torque timer.

Programmable Auto-Restart Dry-Run Timer
Stops the pump on dry run and retries after the configured recovery delay.

Timer Power-Failure Recovery
Restores the programmed timer cycle after a power interruption.
Registration and advanced timer controls

Digital Product Registration
Supports digital product registration for product and service records.

Total Daily Run-Time Control
Limits or tracks the pump's total daily operating time according to the programmed setting.

Cyclic-Timer Operating Hours
Allows the cyclic timer's daily operating window to be configured.

Multi-Event Real-Time Scheduler
Supports up to 20 programmed start and stop events.
Hierarchical Timer
Supports individually configured cycles within a broader operating schedule.
Installation and support

Protective Enclosure

Technical Support
Technical support is available by WhatsApp and call at +91 63588 96254.
Installation Fit
Select the DEV-K4 current setting for the connected motor and have a qualified electrician complete the wiring according to the supplied product wiring guide.
Before Ordering
Before ordering, match the controller current range to your pump motor nameplate. Have a qualified electrician check the wiring and protection settings against the supplied guide. For current shipping, replacement/return and warranty-eligibility information, review the Shipping Policy, Refund Policy and Contact page.
Compare Before Buying
More VUKAR comparisons
Share
Customers are saying

Hello it's working perfectly every day it start by 0600 hrs and stops at 0709 hrs
Motor Starter Panel & Protection Devices
View all-
Single Phase Borewell Level Control Panels (BOA) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Single Phase Borewell Level Control Panels (BOA) options compare ಮಾಡಿ. ಆಯ್ಕೆ...
-
Three Phase Digital Auto Switch for Water Pumps ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Digital Auto Switch for Water Pumps options compare ಮಾಡಿ....
-
VUKARನ ಎಲ್ಲಾ Products
ಒಂದೇ listingನಲ್ಲಿ ಪೂರ್ಣ VUKAR catalogue ನೋಡಿ: starter panels, auto switches, water level...
-
Three Phase Borewell DOL Panels with Timer (TPM) ಕಲೆಕ್ಷನ್
ಇಲ್ಲಿ Three Phase Borewell DOL Panels with Timer (TPM) options compare ಮಾಡಿ....
Blog posts
View all-
TPM-W ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-W tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ level, float indicator ಮತ್ತು pumpನ RUN ಅಥವಾ rest ಬರೆಯಿರಿ.
TPM-W ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-W tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ level, float indicator ಮತ್ತು pumpನ RUN ಅಥವಾ rest ಬರೆಯಿರಿ.
-
TPM-V ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-V tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ ನೀರಿನ ಮಟ್ಟ ಮತ್ತು indicator ಅನ್ನು ಒಂದೇ ಹೊತ್ತಿನಲ್ಲಿ ಬರೆಯಿರಿ.
TPM-V ಟ್ಯಾಂಕ್ level display ತಪ್ಪು? Float indica...
Mohit VekariaTPM-V tank level display ತಪ್ಪಾಗಿ ಕಂಡರೆ ನಿಜವಾದ ನೀರಿನ ಮಟ್ಟ ಮತ್ತು indicator ಅನ್ನು ಒಂದೇ ಹೊತ್ತಿನಲ್ಲಿ ಬರೆಯಿರಿ.
-
TPM-T daily run time ಬೇಗ ನಿಲ್ಲುತ್ತದೆ? ವಿದ್ಯುತ್ ...
Mohit VekariaTPM-T daily run time ಬೇಗ ನಿಂತಂತೆ ಕಂಡರೆ ಮೋಟರ್ ನಿಜವಾಗಿ ಓಡಿದ ನಿಮಿಷಗಳು ಮತ್ತು ವಿದ್ಯುತ್ ಮರಳಿದ ಸಮಯ ದಾಖಲಿಸಿ.
TPM-T daily run time ಬೇಗ ನಿಲ್ಲುತ್ತದೆ? ವಿದ್ಯುತ್ ...
Mohit VekariaTPM-T daily run time ಬೇಗ ನಿಂತಂತೆ ಕಂಡರೆ ಮೋಟರ್ ನಿಜವಾಗಿ ಓಡಿದ ನಿಮಿಷಗಳು ಮತ್ತು ವಿದ್ಯುತ್ ಮರಳಿದ ಸಮಯ ದಾಖಲಿಸಿ.
-
TPM-H three-phase pump ಮತ್ತೆ ಮತ್ತೆ trip? Cyclic...
Mohit VekariaTPM-H three-phase pump ಮತ್ತೆ ಮತ್ತೆ trip ಆಗುತ್ತಿದೆ ಎಂದರೆ ಮೋಟರ್ ನಿಂತಿತೇ, overload ಸೂಚನೆ ಬಂತೇ ಅಥವಾ built-in MCB ಸ್ಥಾನ ಬದಲಾಯಿತೇ ಎಂದು ದಾಖಲಿಸಿ.
TPM-H three-phase pump ಮತ್ತೆ ಮತ್ತೆ trip? Cyclic...
Mohit VekariaTPM-H three-phase pump ಮತ್ತೆ ಮತ್ತೆ trip ಆಗುತ್ತಿದೆ ಎಂದರೆ ಮೋಟರ್ ನಿಂತಿತೇ, overload ಸೂಚನೆ ಬಂತೇ ಅಥವಾ built-in MCB ಸ್ಥಾನ ಬದಲಾಯಿತೇ ಎಂದು ದಾಖಲಿಸಿ.
Blog posts
View all-
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
WhatsApp ಮೂಲಕ VUKAR ವಾರಂಟಿ ನೋಂದಣಿ
ಡಿಜಿಟಲ್ ಮೀಟರ್ನಲ್ಲಿ WRT ತಲುಪಿ, 3 ಅಂಕಿಯ ಕೋಡ್ ಅಥವಾ ಫೋಟೋವನ್ನು WhatsApp ಮೂಲಕ ಕಳುಹಿಸಿ. ಪಾಸ್ವರ್ಡ್ ನಮೂದಿಸಿ ಸಾಧನವನ್ನು ಮತ್ತೆ ಆನ್ ಮಾಡಿ.
-
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
Relay ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ: Interactive Pump Sta...
Interactive relay walkthroughನಲ್ಲಿ pump start requestನ ಮಾರ್ಗ ನೋಡಿ ಮತ್ತು ನಾಲ್ಕು ಸಾಮಾನ್ಯ faults control sequence ಅನ್ನು ಎಲ್ಲಿ ನಿಲ್ಲಿಸುತ್ತವೆ ಎಂದು ತಿಳಿಯಿರಿ.
-
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
Megger Test: ಉದ್ದೇಶ, ವಿಧಾನ ಮತ್ತು Insulation Res...
Motor insulation resistance ತಿಳಿಯಿರಿ. ಕಡಿಮೆಯಾಗುವ megohm reading ಏನು ಸೂಚಿಸಬಹುದು ಮತ್ತು test reportನಲ್ಲಿ ಯಾವ ಮಾಹಿತಿ ಕೇಳಬೇಕು ಎಂದು ನೋಡಿ.
-
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.
RCBO Full Form: ಹೇಗೆ ಕೆಲಸ ಮಾಡುತ್ತದೆ ಮತ್ತು RCCBಗ...
RCBO ಏನನ್ನು ರಕ್ಷಿಸುತ್ತದೆ, markings ಹೇಗೆ ಓದಬೇಕು ಮತ್ತು RCCB ಹಾಗೂ ಪ್ರತ್ಯೇಕ MCBಗಳ ಜೊತೆ ಹೋಲಿಕೆ ಹೇಗಿದೆ ಎಂದು ನೋಡಿ.